191 related articles for article (PubMed ID: 15761296)
1. Performance characteristics of a commercially available whole body counting phantom measured experimentally and using Monte Carlo simulations.
Kramer GH; Hauck BM; Capello K
Health Phys; 2005 Apr; 88(4):350-6. PubMed ID: 15761296
[TBL] [Abstract][Full Text] [Related]
2. The W-chair whole body counter: a Monte Carlo investigation.
Kramer GH; Capello K; Ross K
Health Phys; 2005 Apr; 88(4):364-70. PubMed ID: 15761298
[TBL] [Abstract][Full Text] [Related]
3. Effect of lung volume on counting efficiency: a Monte Carlo investigation.
Kramer GH; Capello K
Health Phys; 2005 Apr; 88(4):357-63. PubMed ID: 15761297
[TBL] [Abstract][Full Text] [Related]
4. The standfast whole body counter and the sliced BOMAB phantom: efficiency as a function of number of sources and energy modeled by MCNP5.
Kramer GH; Capello K
Health Phys; 2007 Feb; 92(2):170-5. PubMed ID: 17220718
[TBL] [Abstract][Full Text] [Related]
5. Application of voxel phantoms and Monte Carlo method to whole-body counter calibration.
Kinase S; Takagi S; Noguchi H; Saito K
Radiat Prot Dosimetry; 2007; 125(1-4):189-93. PubMed ID: 17522042
[TBL] [Abstract][Full Text] [Related]
6. Voxel phantoms: NORMAN vs. VIP-Man, what differences are there?
Kramer GH; Capello K; Cardenas-Mendez E
Health Phys; 2009 Feb; 96(2 Suppl):S22-6. PubMed ID: 19125052
[TBL] [Abstract][Full Text] [Related]
7. Monte Carlo comparison of the St Petersburg phantom with a BOMAB phantom in the HML's whole-body counter.
Kramer GH; Capello K; Sung J
Radiat Prot Dosimetry; 2008; 128(2):245-50. PubMed ID: 17562658
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo simulation of a scanning detector whole body counter and the effect of BOMAB phantom size on the calibration.
Kramer GH; Burns LC; Guerriere S
Health Phys; 2002 Oct; 83(4):526-33. PubMed ID: 12240728
[TBL] [Abstract][Full Text] [Related]
9. Measurement and Simulation of the Counting Efficiency of a Whole-body Counter Using a BOMAB Phantom Inserted with Rod Sources Containing Mixed Radionuclides.
Park M; Yoo J; Ha WH; Park S; Jin YW
Health Phys; 2018 Mar; 114(3):282-287. PubMed ID: 29360706
[TBL] [Abstract][Full Text] [Related]
10. Comparison of the St. Petersburg phantom with a BOMAB phantom in the ORTEC StandFast whole body counter: a Monte Carlo simulation.
Kramer GH; Capello K; Sung J
Health Phys; 2008 May; 94(5 Suppl 2):S78-82. PubMed ID: 18403961
[TBL] [Abstract][Full Text] [Related]
11. Effect of mass, at a fixed height, on the counting efficiency of a BOMAB phantom in three types of whole body counter modeled by MCNP5.
Kramer GH; Capello K; Phan Q
Health Phys; 2008 Aug; 95(2):234-40. PubMed ID: 18617805
[TBL] [Abstract][Full Text] [Related]
12. Improvement of the WBC calibration of the Internal Dosimetry Laboratory of the CDTN/CNEN using the physical phantom BOMAB and MCNPX code.
Paiva FG; Oliveira AH; Mendes BM; Pinto JR; Filho ND; Dantas BM; Dantas AL; Silva TA; Lacerda MA; Fonseca TC
Appl Radiat Isot; 2016 Nov; 117():123-127. PubMed ID: 26778764
[TBL] [Abstract][Full Text] [Related]
13. The StandFast whole body counter: efficiency as a function of BOMAB phantom size and energy modeled by MCNP5.
Kramer GH; Capello K
Health Phys; 2007 Mar; 92(3):290-6. PubMed ID: 17293701
[TBL] [Abstract][Full Text] [Related]
14. Validation of a Monte Carlo efficiency calibration procedure for a partial body counter system with a voxel model of the LLNL torso phantom.
Hegenbart L; Marzocchi O; Breustedt B; Urban M
Radiat Prot Dosimetry; 2009 Feb; 133(3):158-64. PubMed ID: 19304770
[TBL] [Abstract][Full Text] [Related]
15. Application of Monte Carlo calculation and OEDIPE software for virtual calibration of an in vivo counting system.
Liye L; Franck D; de Carlan L; Junli L
Radiat Prot Dosimetry; 2007; 127(1-4):282-6. PubMed ID: 18077473
[TBL] [Abstract][Full Text] [Related]
16. HML's whole body counter: measuring highly radioactive persons.
Kramer GH; Capello K; Chiang A; Hauck BM
Health Phys; 2009 Dec; 97(6):630-6. PubMed ID: 19901599
[TBL] [Abstract][Full Text] [Related]
17. Use of photographic images to construct voxel phantoms for use in whole-body counting.
Kim JS; Ha WH; Jeong JH; Cho KW; Lee JK
Radiat Prot Dosimetry; 2010 Feb; 138(2):119-22. PubMed ID: 19951986
[TBL] [Abstract][Full Text] [Related]
18. New method of voxel phantom creation: application for whole-body counting calibration and perspectives in individual internal dose assessment.
de Carlan L; Roch P; Blanchardon E; Franck D
Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):160-4. PubMed ID: 16604619
[TBL] [Abstract][Full Text] [Related]
19. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models.
Jarry G; DeMarco JJ; Beifuss U; Cagnon CH; McNitt-Gray MF
Phys Med Biol; 2003 Aug; 48(16):2645-63. PubMed ID: 12974580
[TBL] [Abstract][Full Text] [Related]
20. Monte Carlo simulation of the movement and detection efficiency of a whole-body counting system using a BOMAB phantom.
Bento J; Barros S; Teles P; Neves M; Gonçalves I; Corisco J; Vaz P
Radiat Prot Dosimetry; 2012 Mar; 148(4):403-13. PubMed ID: 21525044
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]