These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
150 related articles for article (PubMed ID: 15761297)
21. New method of voxel phantom creation: application for whole-body counting calibration and perspectives in individual internal dose assessment. de Carlan L; Roch P; Blanchardon E; Franck D Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):160-4. PubMed ID: 16604619 [TBL] [Abstract][Full Text] [Related]
22. Study of the influence of radionuclide biokinetics on the efficiency of in vivo counting using Monte Carlo simulation. Lamart S; Blanchardon E; Molokanov A; Kramer GH; Broggio D; Franck D Health Phys; 2009 May; 96(5):558-67. PubMed ID: 19359849 [TBL] [Abstract][Full Text] [Related]
23. Monte Carlo calculations for efficiency calibration of a whole-body monitor using BOMAB phantoms of different sizes. Bhati S; Patni HK; Ghare VP; Singh IS; Nadar MY Radiat Prot Dosimetry; 2012 Mar; 148(4):414-9. PubMed ID: 21531750 [TBL] [Abstract][Full Text] [Related]
24. Monte Carlo comparison of the St Petersburg phantom with a BOMAB phantom in the HML's whole-body counter. Kramer GH; Capello K; Sung J Radiat Prot Dosimetry; 2008; 128(2):245-50. PubMed ID: 17562658 [TBL] [Abstract][Full Text] [Related]
25. The application of voxel phantoms to the internal dosimetry of radionuclides. Zankl M; Petoussi-Henss N; Fill U; Regulla D Radiat Prot Dosimetry; 2003; 105(1-4):539-48. PubMed ID: 14527024 [TBL] [Abstract][Full Text] [Related]
26. Use of photographic images to construct voxel phantoms for use in whole-body counting. Kim JS; Ha WH; Jeong JH; Cho KW; Lee JK Radiat Prot Dosimetry; 2010 Feb; 138(2):119-22. PubMed ID: 19951986 [TBL] [Abstract][Full Text] [Related]
27. An analysis of dependency of counting efficiency on worker anatomy for in vivo measurements: whole-body counting. Zhang B; Mille M; Xu XG Phys Med Biol; 2008 Jul; 53(13):3463-75. PubMed ID: 18547914 [TBL] [Abstract][Full Text] [Related]
28. Evaluation of specific absorbed fractions from internal photon sources in ORNL analytical adult phantom. Hakimabad HM; Motavalli LR Radiat Prot Dosimetry; 2008; 128(4):427-31. PubMed ID: 17951243 [TBL] [Abstract][Full Text] [Related]
29. An approach for the efficiency calibration of whole body counters. Venturini L; Campos VP; Berti EA Health Phys; 2001 Nov; 81(5):580-4. PubMed ID: 11669212 [TBL] [Abstract][Full Text] [Related]
30. Patient-specific scaling of reference S-values for cross-organ radionuclide S-values: what is appropriate? Petoussi-Henss N; Bolch WE; Zankl M; Sgouros G; Wessels B Radiat Prot Dosimetry; 2007; 127(1-4):192-6. PubMed ID: 17569687 [TBL] [Abstract][Full Text] [Related]
31. CRUCIAL PARAMETERS FOR PROPER SIMULATION OF THE DETECTOR USED IN IN VIVO MEASUREMENTS. Vrba T Radiat Prot Dosimetry; 2016 Sep; 170(1-4):359-63. PubMed ID: 26743254 [TBL] [Abstract][Full Text] [Related]
32. Evaluation of self-dose S values for positron emitters in voxel phantoms. Kinase S; Saito K Radiat Prot Dosimetry; 2007; 127(1-4):197-200. PubMed ID: 17627951 [TBL] [Abstract][Full Text] [Related]
33. Fluence-to-effective dose conversion coefficients from a Saudi population based phantom for monoenergetic photon beams from 10 keV to 20 MeV. Ma AK; Hussein MA; Altaher KM; Farid KY; Amer M; Aldhafery BF; Alghamdi AA J Radiol Prot; 2015 Mar; 35(1):75-86. PubMed ID: 25517542 [TBL] [Abstract][Full Text] [Related]
34. Effect of mass, at a fixed height, on the counting efficiency of a BOMAB phantom in three types of whole body counter modeled by MCNP5. Kramer GH; Capello K; Phan Q Health Phys; 2008 Aug; 95(2):234-40. PubMed ID: 18617805 [TBL] [Abstract][Full Text] [Related]
35. Monte Carlo simulation of the movement and detection efficiency of a whole-body counting system using a BOMAB phantom. Bento J; Barros S; Teles P; Neves M; Gonçalves I; Corisco J; Vaz P Radiat Prot Dosimetry; 2012 Mar; 148(4):403-13. PubMed ID: 21525044 [TBL] [Abstract][Full Text] [Related]
36. A Monte Carlo calibration of a whole body counter using the ICRP computational phantoms. Nilsson J; Isaksson M Radiat Prot Dosimetry; 2015 Mar; 163(4):458-67. PubMed ID: 25147249 [TBL] [Abstract][Full Text] [Related]
37. Whole body counter calibration using Monte Carlo modeling with an array of phantom sizes based on national anthropometric reference data. Shypailo RJ; Ellis KJ Phys Med Biol; 2011 May; 56(10):2979-97. PubMed ID: 21490381 [TBL] [Abstract][Full Text] [Related]
38. Phantom size in brachytherapy source dosimetric studies. Pérez-Calatayud J; Granero D; Ballester F Med Phys; 2004 Jul; 31(7):2075-81. PubMed ID: 15305460 [TBL] [Abstract][Full Text] [Related]
39. Voxel phantoms and Monte Carlo methods applied to in vivo measurements for simultaneous 241Am contamination in four body regions. Hunt JG; Dantas BM; Lourenço MC; Azeredo AM Radiat Prot Dosimetry; 2003; 105(1-4):549-52. PubMed ID: 14527025 [TBL] [Abstract][Full Text] [Related]
40. Application of a Ge semi-conductor detector to whole-body counter. Kinase S; Noguchi H; Nakamura T Radiat Prot Dosimetry; 2003; 105(1-4):467-72. PubMed ID: 14527010 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]