These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Total and direct-reacting bilirubin values by automated methods compared with liquid chromatography and with manual methods for determining delta bilirubin. Rosenthal P; Keefe MT; Henton D; Cheng M; Lee CR; Hall RL; Newton MK Clin Chem; 1990 May; 36(5):788-91. PubMed ID: 2337992 [TBL] [Abstract][Full Text] [Related]
3. Conjugated bilirubin: a better indicator of impaired hepatobiliary excretion than direct bilirubin. Arvan D; Shirey TL Ann Clin Lab Sci; 1985; 15(3):252-9. PubMed ID: 3994295 [TBL] [Abstract][Full Text] [Related]
4. Estimation of total and direct serum bilirubin using modified micro assay method. Aman A; Ul Qader SA; Bano S Ital J Biochem; 2007 Jun; 56(2):171-5. PubMed ID: 17722660 [TBL] [Abstract][Full Text] [Related]
5. Serum bilirubin fractionation using multilayer film method in hepatobiliary diseases in comparison with high performance liquid chromatography. Adachi Y; Inufusa H; Yamashita M; Ozaki K; Kanbe A; Nanno T; Ohba Y; Nakamura H; Yamamoto T Gastroenterol Jpn; 1987 Oct; 22(5):633-9. PubMed ID: 3678733 [TBL] [Abstract][Full Text] [Related]
6. Specific pattern of unconjugated bilirubin during fasting can identify constitutional hyperbilirubinemia. Baldassare V; Ricci GL Ital J Gastroenterol; 1993; 25(7):375-9. PubMed ID: 8280899 [TBL] [Abstract][Full Text] [Related]
7. The Ektachem clinical chemistry slide for simultaneous determination of unconjugated and sugar-conjugated bilirubin. Wu TW; Dappen GM; Spayd RW; Sundberg MW; Powers DM Clin Chem; 1984 Aug; 30(8):1304-9. PubMed ID: 6744576 [TBL] [Abstract][Full Text] [Related]
8. Methotrexate interferes with determinations of conjugated bilirubin with the Kodak Ektachem 400. Swanson S; Mifflin TE; Boyd JC Clin Chem; 1986 May; 32(5):863-4. PubMed ID: 3457654 [TBL] [Abstract][Full Text] [Related]
9. Influence of photoisomers in bilirubin determinations on Kodak Ektachem and Hitachi analysers in neonatal specimens study of the contribution of structural and configurational isomers. Gulian JM; Dalmasso C; Millet V; Unal D; Charrel M Eur J Clin Chem Clin Biochem; 1995 Aug; 33(8):503-12. PubMed ID: 8547434 [TBL] [Abstract][Full Text] [Related]
10. Determination of conjugated and total bilirubin in serum of neonates, with use of bilirubin oxidase. Mullon CJ; Langer R Clin Chem; 1987 Oct; 33(10):1822-5. PubMed ID: 3665037 [TBL] [Abstract][Full Text] [Related]
11. The Kodak Ektachem clinical chemistry slide for measurement of bilirubin in newborns: principles and performance. Wu TW; Dappen GM; Powers DM; Lo DH; Rand RN; Spayd RW Clin Chem; 1982 Dec; 28(12):2366-72. PubMed ID: 7139916 [TBL] [Abstract][Full Text] [Related]
12. [Evaluation of the technique of CKMB assay using Ektachem (500 and 700)]. Benattar C; Chalas J; Vassault A; Taieb J; Lindenbaum A Ann Biol Clin (Paris); 1994; 52(1):45-8. PubMed ID: 8210073 [TBL] [Abstract][Full Text] [Related]
13. Clinical utility of Ektachem-determined bilirubin fractions for classifying adult inpatients. Tetrault GA; Meiklejohn BA; Sparks CE Clin Chem; 1987 Sep; 33(9):1662-4. PubMed ID: 3621569 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of the Kodak EKTACHEM clinical chemistry slide for the measurement of bilirubin in newborns. Ou CN; Gilman GE; Buffone GJ Clin Chim Acta; 1984 Jul; 140(2):167-72. PubMed ID: 6467608 [TBL] [Abstract][Full Text] [Related]
16. The laboratory method as a variable in the interpretation of serum bilirubin fractionation. Killenberg PG; Stevens RD; Wildermann RF; Wildermann NM Gastroenterology; 1980 May; 78(5 Pt 1):1011-5. PubMed ID: 7380173 [TBL] [Abstract][Full Text] [Related]
17. [Determination of serum bilirubin fractions using gel-filtration]. Franzini C; Cattozzo G; Pagani A Quad Sclavo Diagn; 1988; 24(1-4):1-8. PubMed ID: 3268902 [TBL] [Abstract][Full Text] [Related]
18. The occurrence and significance of the bilirubin species, including delta bilirubin, in jaundiced infants. Ostrea EM; Ongtengco EA; Tolia VA; Apostol E J Pediatr Gastroenterol Nutr; 1988; 7(4):511-6. PubMed ID: 3397842 [TBL] [Abstract][Full Text] [Related]
19. Estimation of unconjugated, conjugated, and "delta" bilirubin fractions in serum by use of two coated thin films. Sundberg MW; Lauff JJ; Weiss JS; Dappen GM; Wu TW; Spayd RW; Seligson D Clin Chem; 1984 Aug; 30(8):1314-7. PubMed ID: 6744578 [TBL] [Abstract][Full Text] [Related]
20. Analyses with the KODAK-Ektachem. Accuracy control using reference method values and the influence of protein concentration. Part II. Substrates. Külpmann WR; Maibaum P; Sonntag O; Schumann G; Siekmann L J Clin Chem Clin Biochem; 1990 Nov; 28(11):835-43. PubMed ID: 2077096 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]