444 related articles for article (PubMed ID: 15763537)
1. Inappropriate implantable cardioverter-defibrillator shock due to external alternating current leak: report of two cases.
Chan NY; Wai-Ling Ho L
Europace; 2005 Mar; 7(2):193-6. PubMed ID: 15763537
[TBL] [Abstract][Full Text] [Related]
2. Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site.
Fetter JG; Benditt DG; Stanton MS
J Am Coll Cardiol; 1996 Aug; 28(2):423-7. PubMed ID: 8800120
[TBL] [Abstract][Full Text] [Related]
3. Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias.
Occhetta E; Bortnik M; Magnani A; Francalacci G; Marino P
Europace; 2006 Oct; 8(10):863-9. PubMed ID: 16916859
[TBL] [Abstract][Full Text] [Related]
4. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical interference with washing machine.
Chongtham DS; Bahl A; Kumar RM; Talwar KK
Int J Cardiol; 2007 May; 118(2):e44-5. PubMed ID: 17395291
[TBL] [Abstract][Full Text] [Related]
5. Detection of refrigerator-associated 60 Hz alternating current as ventricular fibrillation by an implantable defibrillator.
Al Khadra AS; Al Jutaily A; Al Shuhri S
Europace; 2006 Mar; 8(3):175-7. PubMed ID: 16627434
[TBL] [Abstract][Full Text] [Related]
6. Non-determinable defibrillation threshold and inefficacy of implantable cardioverter/defibrillator shocks due to defective connections of the defibrillator lead terminals in the device header port.
Maagh P; Trappe HJ; Meissner A
Europace; 2007 Dec; 9(12):1161-2. PubMed ID: 17913694
[TBL] [Abstract][Full Text] [Related]
7. Incidence and causes of inappropriate detection and therapy by implantable defibrillators of cardioversion in patients with ventricular tachyarrhythmia.
Chen RH; Chen KP; Wang FZ; Hua W; Chen X; Zhang S
Chin Med J (Engl); 2006 Apr; 119(7):557-63. PubMed ID: 16620696
[TBL] [Abstract][Full Text] [Related]
8. Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device.
Francisco GM; Sharma S; Dougherty AH; Kantharia BK
Cardiol J; 2009; 16(5):473-6. PubMed ID: 19753529
[TBL] [Abstract][Full Text] [Related]
9. Inappropriate implantable cardioverter-defibrillator shocks due to temporary epicardial pacing.
Gelissen M; Debie L; van Opstal J
Europace; 2010 Nov; 12(11):1648. PubMed ID: 20543194
[TBL] [Abstract][Full Text] [Related]
10. Implantable cardioverter defribrillator shocks: a troubleshooting guide.
Swerdlow CD; Zhang J
Rev Cardiovasc Med; 2001; 2(2):61-72. PubMed ID: 12439383
[TBL] [Abstract][Full Text] [Related]
11. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure.
Spencker S; Coban N; Koch L; Schirdewan A; Müller D
Europace; 2009 Apr; 11(4):483-8. PubMed ID: 19103654
[TBL] [Abstract][Full Text] [Related]
12. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact.
Daubert JP; Zareba W; Cannom DS; McNitt S; Rosero SZ; Wang P; Schuger C; Steinberg JS; Higgins SL; Wilber DJ; Klein H; Andrews ML; Hall WJ; Moss AJ;
J Am Coll Cardiol; 2008 Apr; 51(14):1357-65. PubMed ID: 18387436
[TBL] [Abstract][Full Text] [Related]
13. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical leak from bathroom tap.
Camsarı A; Yılmaz DC; Ozcan T
Clin Res Cardiol; 2010 Nov; 99(11):761-3. PubMed ID: 20683725
[No Abstract] [Full Text] [Related]
14. Inappropriate ICD therapy due to electrical interference: external alternating current leakage.
Paraskevaidis S; Polymeropoulos KP; Louridas G
J Invasive Cardiol; 2004 Jun; 16(6):339. PubMed ID: 15156008
[No Abstract] [Full Text] [Related]
15. Multiple appropriate and spurious defibrillator shocks in a patient with right ventricular cardiomyopathy.
Strohmer B; Schernthaner C; Pichler M
Int J Cardiol; 2005 Jul; 102(2):363-6. PubMed ID: 15982515
[TBL] [Abstract][Full Text] [Related]
16. Induction of ventricular tachycardia by alternate current due to an insufficiently grounded electrical system.
Lappegård KT
Pacing Clin Electrophysiol; 2012 Jun; 35(6):e170-2. PubMed ID: 21091734
[TBL] [Abstract][Full Text] [Related]
17. An unusual mechanism causing inappropriate implantable cardioverter defibrillator shocks: transient reduction in R-wave amplitude.
Baranchuk A; Ribas S; Divakaramenon S; Morillo CA
Europace; 2007 Aug; 9(8):694-6. PubMed ID: 17478463
[TBL] [Abstract][Full Text] [Related]
18. Inappropriate implantable cardioverter defibrillator discharge from sensing of external alternating current leak.
Garg A; Wadhwa M; Brown K; Luckett C; Vaughn T; Birgersdotter-Green U; Feld G
J Interv Card Electrophysiol; 2002 Oct; 7(2):181-4. PubMed ID: 12397229
[TBL] [Abstract][Full Text] [Related]
19. Inappropriate ICD shocks caused by external electrical noise.
Thøgersen AM; Hjortshøj SP; Eskesen K
N Engl J Med; 2009 Mar; 360(13):1363-4. PubMed ID: 19321878
[No Abstract] [Full Text] [Related]
20. Inappropriate sensing of pectoral myopotentials by an implantable cardioverter defibrillator system.
Karanam S; John RM
Pacing Clin Electrophysiol; 2004 May; 27(5):688-9. PubMed ID: 15125734
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]