163 related articles for article (PubMed ID: 15764377)
1. A new method to detect systemic inflammatory response syndrome by continuous monitoring system: an experimental study in rats.
Matsui T; Ishizuka T; Ishihara M; Suzuki M; Kurita A; Kikuchi M
J Med Eng Technol; 2005; 29(1):18-21. PubMed ID: 15764377
[TBL] [Abstract][Full Text] [Related]
2. Use of a thermocouple for malignant tumor detection. Investigating temperature difference as a diagnostic criterion.
Zhao Q; Zhang J; Wang R; Cong W
IEEE Eng Med Biol Mag; 2008; 27(1):64-6. PubMed ID: 18270051
[No Abstract] [Full Text] [Related]
3. A comparative study for the development of a thermal odoscope for the wearable dynamic thermography monitoring.
Giansanti D; Maccioni G; Gigante GE
Med Eng Phys; 2006 May; 28(4):363-71. PubMed ID: 16139557
[TBL] [Abstract][Full Text] [Related]
4. Reliability of body temperature measurements in hospitalised older patients.
Giantin V; Toffanello ED; Enzi G; Perissinotto E; Vangelista S; Simonato M; Ceccato C; Manzato E; Sergi G
J Clin Nurs; 2008 Jun; 17(11):1518-25. PubMed ID: 18482145
[TBL] [Abstract][Full Text] [Related]
5. Heart tissue viability monitoring in vivo by using combined fluorescence, thermography and electrical activity measurements.
Krisciukaitis A; Minet O; Tamosiunas M; Zabarylo U; Bytautas A; Baniene R; Mildaziene V; Lekas R; Jakuska P; Lukosevicius K; Benetis R; Beuthan J
Biomed Tech (Berl); 2005 Dec; 50(12):419-25. PubMed ID: 16429947
[TBL] [Abstract][Full Text] [Related]
6. Utilization of temperature distribution in expiratory speaking flow as a new parameter for speech production analysis.
Gomes GF; Vargas JV; Filho ED
J Med Eng Technol; 2004; 28(1):22-31. PubMed ID: 14660182
[TBL] [Abstract][Full Text] [Related]
7. [A multiparametric monitoring network system based on windows operation system].
Chen ML; He P; Wu XW; Wang BH
Zhongguo Yi Liao Qi Xie Za Zhi; 2000 Feb; 24(2):73-7, 81. PubMed ID: 12583092
[TBL] [Abstract][Full Text] [Related]
8. Development of a continuous temperature mapping system using a deep body thermometer.
Matsui T; Hagisawa K; Ishizuka T; Matsumura K; Ishihara M; Sato S; Takase B; Suzuki M; Kikuchi M; Kurita A
J Med Eng Technol; 2002; 26(3):123-5. PubMed ID: 12350279
[TBL] [Abstract][Full Text] [Related]
9. [A new technology for evaluation the functional condition of the cardiovascular system].
Zhuravlev VF; Zhuravleva NV
Med Tekh; 2004; (4):22-7. PubMed ID: 15455819
[TBL] [Abstract][Full Text] [Related]
10. Measurement of human heartbeat and respiration signals using phase detection radar.
Kim HJ; Kim KH; Hong YS; Choi JJ
Rev Sci Instrum; 2007 Oct; 78(10):104703. PubMed ID: 17979445
[TBL] [Abstract][Full Text] [Related]
11. Assessment of a new piezoelectric transducer sensor for noninvasive cardiorespiratory monitoring of newborn infants in the NICU.
Sato S; Ishida-Nakajima W; Ishida A; Kawamura M; Miura S; Ono K; Inagaki N; Takada G; Takahashi T
Neonatology; 2010; 98(2):179-90. PubMed ID: 20234143
[TBL] [Abstract][Full Text] [Related]
12. Development and testing of a wearable Integrated Thermometer sensor for skin contact thermography.
Giansanti D; Maccioni G
Med Eng Phys; 2007 Jun; 29(5):556-65. PubMed ID: 16934515
[TBL] [Abstract][Full Text] [Related]
13. [Automated biomedical complexes for rapid temperature diagnosis].
Kravchenko AM; Anokhin AM
Med Tekh; 2010; (2):21-6. PubMed ID: 20458982
[No Abstract] [Full Text] [Related]
14. Acetylcholine release, EEG spectral analysis, sleep staging and body temperature studies: a multiparametric approach on freely moving rats.
Crouzier D; Baubichon D; Bourbon F; Testylier G
J Neurosci Methods; 2006 Mar; 151(2):159-67. PubMed ID: 16139894
[TBL] [Abstract][Full Text] [Related]
15. Rapid assay for plasma soluble E-selectin predicts the development of acute respiratory distress syndrome in patients with systemic inflammatory response syndrome.
Okajima K; Harada N; Sakurai G; Soga Y; Suga H; Terada T; Nakagawa T
Transl Res; 2006 Dec; 148(6):295-300. PubMed ID: 17162250
[TBL] [Abstract][Full Text] [Related]
16. Breathing detection: towards a miniaturized, wearable, battery-operated monitoring system.
Corbishley P; RodrÃguez-Villegas E
IEEE Trans Biomed Eng; 2008 Jan; 55(1):196-204. PubMed ID: 18232362
[TBL] [Abstract][Full Text] [Related]
17. [A design of the circuit of a monitoring system for respiratory mechanical parameters].
Li DW; Qiu YY; Ye JL
Zhongguo Yi Liao Qi Xie Za Zhi; 2005 Mar; 29(2):92-5. PubMed ID: 16011111
[TBL] [Abstract][Full Text] [Related]
18. Modern pacemakers: hope or hype?
DAS MK; Dandamudi G; Steiner HA
Pacing Clin Electrophysiol; 2009 Sep; 32(9):1207-21. PubMed ID: 19719501
[TBL] [Abstract][Full Text] [Related]
19. [Relationship between heart rate variability and serum levels of thyroid hormones, cortisol and prognosis in patients with systemic inflammatory response syndrome].
Xu L; Li CS
Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2007 Mar; 19(3):160-4. PubMed ID: 17376271
[TBL] [Abstract][Full Text] [Related]
20. A wearable, mobile phone-based respiration monitoring system for sleep apnea syndrome detection.
Ishida R; Yonezawa Y; Maki H; Ogawa H; Ninomiya I; Sada K; Hamada S; Hahn AW; Caldwell WM
Biomed Sci Instrum; 2005; 41():289-93. PubMed ID: 15850120
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]