129 related articles for article (PubMed ID: 15765989)
1. [Ability of leukocyte reduction filters to remove fat particles from blood in experimental models simulating blood salvage in orthopedic surgery].
Muñoz Gómez M; Romero Ruiz A; Ariza Villanueva D; Muñoz Morán E; Hernández Lamas MC; Ramírez Ramírez G
Rev Esp Anestesiol Reanim; 2005 Feb; 52(2):81-7. PubMed ID: 15765989
[TBL] [Abstract][Full Text] [Related]
2. Clinical efficacy and biocompatibility of three different leukocyte and fat removal filters during cardiac surgery.
de Vries AJ; Vermeijden WJ; Gu YJ; Hagenaars JA; van Oeveren W
Artif Organs; 2006 Jun; 30(6):452-7. PubMed ID: 16734597
[TBL] [Abstract][Full Text] [Related]
3. [Evaluation of the OrthoPAT autologous transfusion system by experimental models simulating intra- and postoperative blood salvage].
Muñoz Gómez M; Ariza Villanueva D; Romero Ruiz A; Muñoz Morán E; Prat Arrojo I; Gómez Luque A
Rev Esp Anestesiol Reanim; 2005; 52(6):321-7. PubMed ID: 16038171
[TBL] [Abstract][Full Text] [Related]
4. Can a leukocyte depletion filter (LDF) reduce the risk of reintroduction of hepatocellular carcinoma cells?
Gwak MS; Lee KW; Kim SY; Lee J; Joh JW; Kim SJ; Lee HH; Park JW; Kim GS; Lee SK
Liver Transpl; 2005 Mar; 11(3):331-5. PubMed ID: 15719385
[TBL] [Abstract][Full Text] [Related]
5. Removal of Plasmodium falciparum-infected red blood cells from whole blood by leukoreduction filters.
Cardo LJ; Salata J; Wilder D
Transfusion; 2009 Feb; 49(2):337-46. PubMed ID: 19389214
[TBL] [Abstract][Full Text] [Related]
6. Detection and removal of fat particles from postoperative salvaged blood in orthopedic surgery.
Ramírez G; Romero A; García-Vallejo JJ; Muñoz M
Transfusion; 2002 Jan; 42(1):66-75. PubMed ID: 11896315
[TBL] [Abstract][Full Text] [Related]
7. [Autotransfusion after orthopedic surgery. Analysis of quality, safety and efficacy of salvaged shed blood].
Muñoz Gómez M; García Vallejo J; López-Andrade Jurado A; Gómez Luque A; Ruiz Romero De La Cruz M; Maldonado Eloy-García J
Rev Esp Anestesiol Reanim; 2001 Mar; 48(3):131-40. PubMed ID: 11333797
[TBL] [Abstract][Full Text] [Related]
8. [The effect of two leukocyte depletion in-line filters on the efficiency of whole blood filtration].
Xie R; Li Y; Huang Y; Mo Q; Dai Y; Tang W
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Aug; 24(4):817-9. PubMed ID: 17899752
[TBL] [Abstract][Full Text] [Related]
9. Filter Buffy Coats (FBC): a source of peripheral blood leukocytes recovered from leukocyte depletion filters.
Meyer TP; Zehnter I; Hofmann B; Zaisserer J; Burkhart J; Rapp S; Weinauer F; Schmitz J; Illert WE
J Immunol Methods; 2005 Dec; 307(1-2):150-66. PubMed ID: 16325197
[TBL] [Abstract][Full Text] [Related]
10. The potential for reintroduction of tumor cells during intraoperative blood salvage: reduction of risk with use of the RC-400 leukocyte depletion filter.
Edelman MJ; Potter P; Mahaffey KG; Frink R; Leidich RB
Urology; 1996 Feb; 47(2):179-81. PubMed ID: 8607229
[TBL] [Abstract][Full Text] [Related]
11. Effects of a leukocyte depleting arterial line filter on perioperative morbidity in patients undergoing cardiac surgery: a controlled randomized trial.
Leal-Noval SR; Amaya R; Herruzo A; Hernández A; Ordóñez A; Marín-Niebla A; Camacho P
Ann Thorac Surg; 2005 Oct; 80(4):1394-400. PubMed ID: 16181877
[TBL] [Abstract][Full Text] [Related]
12. Antigenicity and irritancy tests of leukocyte-reduction filters using animal models.
Kokubunji A; Natsuaki M; Kano K; Kai S; Hara H; Nishio H; Sato S
Kobe J Med Sci; 2006; 52(1-2):17-26. PubMed ID: 16609272
[TBL] [Abstract][Full Text] [Related]
13. Leukocytes-depleting filters preferentially remove activated leukocytes and reduce the expression of surface adhesion molecules during the simulated extracorporeal circulation of human blood.
Alexiou C; Sheppard S; Tang A; Rengarajan A; Smith D; Haw M; Gibbs R
ASAIO J; 2006; 52(4):438-44. PubMed ID: 16883125
[TBL] [Abstract][Full Text] [Related]
14. Efficiency of leukocyte depletion filters and micro-aggregate filters following intra-operative cell salvage during cesarean delivery.
Fujioka I; Ichikawa Y; Nakajima Y; Kasahara M; Hattori M; Nemoto T
Int J Obstet Anesth; 2020 Feb; 41():59-64. PubMed ID: 31358431
[TBL] [Abstract][Full Text] [Related]
15. Leukodepletion filters reduce Leishmania in blood products when used at collection or at the bedside.
Cardo LJ; Salata J; Harman R; Mendez J; Weina PJ
Transfusion; 2006 Jun; 46(6):896-902. PubMed ID: 16734805
[TBL] [Abstract][Full Text] [Related]
16. Assessment of the availability of intraoperative autotransfusion in urological operations.
Park KI; Kojima O; Tomoyoshi T
J Urol; 1997 May; 157(5):1777-80. PubMed ID: 9112526
[TBL] [Abstract][Full Text] [Related]
17. Leukocyte removal efficiency of cell-washed and unwashed whole blood: an in vitro study.
ten Brinke MJ; Weerwind PW; Teerenstra S; Feron JC; van der Meer W; Brouwer MH
Perfusion; 2005 Oct; 20(6):335-41. PubMed ID: 16363319
[TBL] [Abstract][Full Text] [Related]
18. In-line filtration of autologous whole blood.
Karger R; Schmidt J; Weber C; Weiler-Lorentz A; Frietsch T; Kretschmer V
Transfusion; 2006 May; 46(5):811-7. PubMed ID: 16686849
[TBL] [Abstract][Full Text] [Related]
19. Use of a leucocyte filter to remove tumour cells from intra-operative cell salvage blood.
Catling S; Williams S; Freites O; Rees M; Davies C; Hopkins L
Anaesthesia; 2008 Dec; 63(12):1332-8. PubMed ID: 19032302
[TBL] [Abstract][Full Text] [Related]
20. Molecular evidence of tumour cell removal from salvaged blood after irradiation and leucocyte depletion.
Poli MC; Villa LL; Colella R; Deheinzelin D
Transfus Med; 2004 Apr; 14(2):151-5. PubMed ID: 15113379
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]