These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

259 related articles for article (PubMed ID: 15769688)

  • 1. Extracorporeal circulation without external clamping and cannulation of the aorta: transventricular placement of a new multifunctional aortic cannula.
    Scheule AM; Beierlein W; Straub A; Ziemer G
    Heart Surg Forum; 2004; 7(6):E569-70. PubMed ID: 15769688
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Distribution of oxygenated blood by transseptal left atrial cannulation during lung support in the open-chest model.
    Miyamoto AT; Matloff JM
    J Thorac Cardiovasc Surg; 1979 Mar; 77(3):396-401. PubMed ID: 762983
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The ESTECH remote access perfusion cannula in minimally invasive cardiac surgery.
    Schachner T; Bonaros N; Laufer G; Bonatti J
    Heart Surg Forum; 2004; 7(6):E632-5. PubMed ID: 15769697
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Modified aortic cannulation for cardiopulmonary bypass in neonatal piglet model.
    Tirilomis T; Paz D; Nolte L; Schoendube FA
    J Card Surg; 2008; 23(5):503-4. PubMed ID: 18928487
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Experimental fluid dynamics of transventricular apical aortic cannulation.
    Fukuda I; Yanaoka H; Inamura T; Minakawa M; Daitoku K; Suzuki Y
    Artif Organs; 2010 Mar; 34(3):222-4. PubMed ID: 20447047
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch.
    Laumen M; Kaufmann T; Timms D; Schlanstein P; Jansen S; Gregory S; Wong KC; Schmitz-Rode T; Steinseifer U
    Artif Organs; 2010 Oct; 34(10):798-806. PubMed ID: 20964698
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Intraoperative aortic injury caused by arterial perfusion cannula during extended aortoplasty in a patient with Williams syndrome].
    Atsumi N; Nakayama S; Kawashima D
    Kyobu Geka; 2010 Aug; 63(9):786-90. PubMed ID: 20715459
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cannulation of the ascending aorta for cardiopulmonary bypass. Experience with 9,000 cases.
    Taylor PC; Groves LK; Loop FD; Effler D
    J Thorac Cardiovasc Surg; 1976 Feb; 71(2):255-8. PubMed ID: 1246151
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of cannula shape on aortic wall and flow turbulence: hydrodynamic study during extracorporeal circulation in mock thoracic aorta.
    Minakawa M; Fukuda I; Yamazaki J; Fukui K; Yanaoka H; Inamura T
    Artif Organs; 2007 Dec; 31(12):880-6. PubMed ID: 17924991
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hydrodynamics of aortic cannulae during extracorporeal circulation in a mock aortic arch aneurysm model.
    Minakawa M; Fukuda I; Igarashi T; Fukui K; Yanaoka H; Inamura T
    Artif Organs; 2010 Feb; 34(2):105-12. PubMed ID: 19995359
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Experimental study on transapical aortic perfusion with a double-barreled cannula and its application to extracorporeal circulation].
    Tanaka T; Hiratsuka H; Matsumoto M; Oara K
    Kyobu Geka; 1974 Aug; 27(8):585-8. PubMed ID: 4477269
    [No Abstract]   [Full Text] [Related]  

  • 12. Surgical treatment of interrupted aortic arch with extraanatomical bypass simultaneous to coronary artery bypass grafting and aortic valve replacement.
    Riess FC; Danne M; Stripling JH; Bergmann H; Bleese N
    Heart Surg Forum; 2004; 7(5):E394-7. PubMed ID: 15799910
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Risk factors for air embolization during cannulation of the ascending aorta.
    Beckman CB; Hurley F; Mammana R; Levitsky S
    J Thorac Cardiovasc Surg; 1980 Aug; 80(2):302-7. PubMed ID: 7401682
    [TBL] [Abstract][Full Text] [Related]  

  • 14. New cannulation technique for the severely calcified ascending aorta.
    Golding LA
    J Thorac Cardiovasc Surg; 1985 Oct; 90(4):626-7. PubMed ID: 4046628
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Numerical simulation of hemodynamics in the ascending aorta induced by different aortic cannulas.
    Stühle S; Wendt D; Jakob H; Kowalczyk W
    Minim Invasive Ther Allied Technol; 2011 Apr; 20(2):125-31. PubMed ID: 21417846
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessment of perfusion toward the aortic valve using the new dispersion aortic cannula during coronary artery bypass surgery.
    Grooters RK; Thieman KC; Schneider RF; Nelson MG
    Tex Heart Inst J; 2000; 27(4):361-5. PubMed ID: 11198309
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Preparation for cardiopulmonary bypass].
    Naruse Y; Tanaka K
    Kyobu Geka; 2010 Jul; 63(8 Suppl):644-8. PubMed ID: 20715433
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cannulation of the noncalcified aorta generates particles of microembolic nature: an experimental study using pig aorta.
    Hedberg M; Funck B; Engström KG
    J Card Surg; 2008; 23(1):39-43. PubMed ID: 18290885
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Single crossclamp improves 6-month cognitive outcome in high-risk coronary bypass patients: the effect of reduced aortic manipulation.
    Hammon JW; Stump DA; Butterworth JF; Moody DM; Rorie K; Deal DD; Kincaid EH; Oaks TE; Kon ND
    J Thorac Cardiovasc Surg; 2006 Jan; 131(1):114-21. PubMed ID: 16399302
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diagnosis and management of severe atherosclerosis of the ascending aorta and aortic arch during cardiac surgery: focus on aortic replacement.
    Zingone B; Rauber E; Gatti G; Pappalardo A; Benussi B; Forti G; Tognolli U; Gabrielli M
    Eur J Cardiothorac Surg; 2007 Jun; 31(6):990-7. PubMed ID: 17383888
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.