180 related articles for article (PubMed ID: 15779841)
1. The pulse in reflectance pulse oximetry: modeling and experimental studies.
Reuss JL; Siker D
J Clin Monit Comput; 2004 Aug; 18(4):289-99. PubMed ID: 15779841
[TBL] [Abstract][Full Text] [Related]
2. Validation of reflectance pulse oximetry: an evaluation of a new sensor in piglets.
Nijland R; Nierlich S; Jongsma HW; Nijhuis JG; Oeseburg B; Springer K; Mannheimer P
J Clin Monit; 1997 Jan; 13(1):43-9. PubMed ID: 9058252
[TBL] [Abstract][Full Text] [Related]
3. Multilayer modeling of reflectance pulse oximetry.
Reuss JL
IEEE Trans Biomed Eng; 2005 Feb; 52(2):153-9. PubMed ID: 15709652
[TBL] [Abstract][Full Text] [Related]
4. The influence of larger subcutaneous blood vessels on pulse oximetry.
Mannheimer PD; O' NM; Konecny E
J Clin Monit Comput; 2004 Jun; 18(3):179-88. PubMed ID: 15562984
[TBL] [Abstract][Full Text] [Related]
5. Does the estimation of light attenuation in tissue increase the accuracy of reflectance pulse oximetry at low oxygen saturations in vivo?
Kisch-Wedel H; Bernreuter P; Kemming G; Albert M; Zwissler B
IEEE Trans Biomed Eng; 2009 Sep; 56(9):2271-9. PubMed ID: 19692303
[TBL] [Abstract][Full Text] [Related]
6. The effect of pulsating arteries on reflectance pulse oximetry: measurements in adults and neonates.
Nijland R; Jongsma HW; van den Berg PP; Nijhuis JG; Oeseburg B
J Clin Monit; 1995 Mar; 11(2):118-22. PubMed ID: 7760084
[TBL] [Abstract][Full Text] [Related]
7. Reflectance pulse oximetry in fetal lambs: subcutaneous vessels and vasoconstriction affect its reliability.
Nijland R; Jongsma HW; Verbruggen IM; Nijhuis JG
J Clin Monit; 1996 May; 12(3):225-30. PubMed ID: 8823646
[TBL] [Abstract][Full Text] [Related]
8. Effect of location of the sensor on reflectance pulse oximetry.
Dassel AC; Graaff R; Aardema M; Zijlstra WG; Aarnoudse JG
Br J Obstet Gynaecol; 1997 Aug; 104(8):910-6. PubMed ID: 9255082
[TBL] [Abstract][Full Text] [Related]
9. Reflectance pulse oximetry in fetal lambs.
Dassel AC; Graaff R; Aarnoudse JG; Elstrodt JM; Heida P; Koelink MH; de Mul FF; Greve J
Pediatr Res; 1992 Mar; 31(3):266-9. PubMed ID: 1561013
[TBL] [Abstract][Full Text] [Related]
10. Factors influencing fetal pulse oximetry performance.
Reuss JL
J Clin Monit Comput; 2004 Feb; 18(1):13-24. PubMed ID: 15139579
[TBL] [Abstract][Full Text] [Related]
11. Toward absolute reflectance oximetry: I. Theoretical consideration for noninvasive tissue reflectance oximetry.
Takatani S
Adv Exp Med Biol; 1989; 248():91-102. PubMed ID: 2782194
[TBL] [Abstract][Full Text] [Related]
12. Modeling of diffuse reflectance of light in heterogeneous biological tissue to analysis of the effects of multiple scattering on reflectance pulse oximetry.
Mehrabi M; Setayeshi S; Ardehali SH; Arabalibeik H
J Biomed Opt; 2017 Jan; 22(1):15004. PubMed ID: 28114451
[TBL] [Abstract][Full Text] [Related]
13. Accuracy of calculated arterial saturation in oxygen in neonatal foals and effects of monitor, sensor, site of sensor placement, and degree of hypoxemia on the accuracy of pulse oximetry.
Giguère S; Sanchez LC; Shih A
J Vet Emerg Crit Care (San Antonio); 2014; 24(5):529-35. PubMed ID: 25212699
[TBL] [Abstract][Full Text] [Related]
14. Reliability of pulse oximetry during cardiopulmonary resuscitation in a piglet model of neonatal cardiac arrest.
Hassan MA; Mendler M; Maurer M; Waitz M; Huang L; Hummler HD
Neonatology; 2015; 107(2):113-9. PubMed ID: 25471619
[TBL] [Abstract][Full Text] [Related]
15. Calibration of a reflectance pulse oximeter in fetal lambs for arterial oxygen saturations below 70%.
Carter AM; Stiller R; König V; Jørgensen JS; Svendsen P; Huch R
J Soc Gynecol Investig; 1998; 5(5):255-9. PubMed ID: 9773401
[TBL] [Abstract][Full Text] [Related]
16. Esophageal pulse oximetry utilizing reflectance photoplethysmography.
Kyriacou PA; Powell S; Langford RM; Jones DP
IEEE Trans Biomed Eng; 2002 Nov; 49(11):1360-8. PubMed ID: 12450366
[TBL] [Abstract][Full Text] [Related]
17. Development and clinical evaluation of a new sensor design for buccal pulse oximetry in horses.
Reiners JK; Rossdeutscher W; Hopster K; Kästner SBR
Equine Vet J; 2018 Mar; 50(2):228-234. PubMed ID: 28833376
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of pulse oximetry in anaesthetised foals using multiple combinations of transducer type and transducer attachment site.
Chaffin MK; Matthews NS; Cohen ND; Carter GK
Equine Vet J; 1996 Nov; 28(6):437-45. PubMed ID: 9049492
[TBL] [Abstract][Full Text] [Related]
19. Pulse oximetry during labour--does it give rise to hope? Value of saturation monitoring in comparison to fetal blood gas status.
Luttkus AK; Callsen TA; Stupin JH; Dudenhausen JW
Eur J Obstet Gynecol Reprod Biol; 2003 Sep; 110 Suppl 1():S132-8. PubMed ID: 12965102
[TBL] [Abstract][Full Text] [Related]
20. Robust Modelling of Reflectance Pulse Oximetry for SpO
Vijayarangan S; Suresh P; Sp P; Joseph J; Sivaprakasam M
Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():374-377. PubMed ID: 33018006
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]