496 related articles for article (PubMed ID: 15794101)
1. [Exhaled tidal volume is overestimated due to cardiogenic oscillation: effects of ventilator and mode].
Imanaka H; Takeuchi M; Tachibana K; Takauchi Y; Inamori N; Nishimura M
Masui; 2005 Mar; 54(3):254-9. PubMed ID: 15794101
[TBL] [Abstract][Full Text] [Related]
2. Expiratory tidal volume displayed on Bird 8400 STi can exceed the preset tidal volume due to cardiogenic oscillation: a lung model study.
Imanaka H; Takeuchi M; Tachibana K; Nishimura M
J Anesth; 2004; 18(4):313-5. PubMed ID: 15549478
[TBL] [Abstract][Full Text] [Related]
3. Exhaled tidal volume overestimation in mechanically ventilated patients with large cardiogenic oscillation.
Imanaka H; Takeuchi M; Tachibana K; Nishimura M
Crit Care Med; 2004 Jul; 32(7):1546-9. PubMed ID: 15241100
[TBL] [Abstract][Full Text] [Related]
4. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
Tung A; Drum ML; Morgan S
J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
[TBL] [Abstract][Full Text] [Related]
5. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
Chow LC; Vanderhal A; Raber J; Sola A
Pediatr Pulmonol; 2002 Sep; 34(3):196-202. PubMed ID: 12203848
[TBL] [Abstract][Full Text] [Related]
6. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator].
Schirmer U; Villwock J; Fösel T; Schreiber M; Goertz A; Georgieff M
Anaesthesist; 1992 Dec; 41(12):785-9. PubMed ID: 1489078
[TBL] [Abstract][Full Text] [Related]
7. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment].
Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH
Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533
[TBL] [Abstract][Full Text] [Related]
8. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
Bachiller PR; McDonough JM; Feldman JM
Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
[TBL] [Abstract][Full Text] [Related]
9. Pressure support and pressure assist/control: are there differences? An evaluation of the newest intensive care unit ventilators.
Williams P; Kratohvil J; Ritz R; Hess DR; Kacmarek RM
Respir Care; 2000 Oct; 45(10):1169-81. PubMed ID: 11054896
[TBL] [Abstract][Full Text] [Related]
10. The impact of closed endotracheal suctioning systems on mechanical ventilator performance.
El Masry A; Williams PF; Chipman DW; Kratohvil JP; Kacmarek RM
Respir Care; 2005 Mar; 50(3):345-53. PubMed ID: 15737244
[TBL] [Abstract][Full Text] [Related]
11. A laboratory evaluation of 2 mechanical ventilators in the presence of helium-oxygen mixtures.
Brown MK; Willms DC
Respir Care; 2005 Mar; 50(3):354-60. PubMed ID: 15737245
[TBL] [Abstract][Full Text] [Related]
12. The effects of tidal volume demand on work of breathing during simulated lung-protective ventilation.
Kallet RH; Alonso JA; Diaz M; Campbell AR; Mackersie RC; Katz JA
Respir Care; 2002 Aug; 47(8):898-909. PubMed ID: 12162801
[TBL] [Abstract][Full Text] [Related]
13. Limiting volume with modern ventilators.
Wing TJ; Haan L; Ashworth LJ; Anderson J
Ther Adv Respir Dis; 2015 Jun; 9(3):75-83. PubMed ID: 25801644
[TBL] [Abstract][Full Text] [Related]
14. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
[TBL] [Abstract][Full Text] [Related]
15. Relationship between endotracheal tube leakage and under-reading of tidal volume in neonatal ventilators.
Mahmoud RA; Fischer HS; Proquitté H; Shalaby HM; Schmalisch G
Acta Paediatr; 2009 Jul; 98(7):1116-22. PubMed ID: 19432838
[TBL] [Abstract][Full Text] [Related]
16. Changes in delivered tidal volume with the addition of carbon dioxide to mechanical ventilation.
Tobias JD; Miltenberg L
Paediatr Anaesth; 2009 Mar; 19(3):240-3. PubMed ID: 19143961
[TBL] [Abstract][Full Text] [Related]
17. Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume.
Al-Majed SI; Thompson JE; Watson KF; Randolph AG
Crit Care; 2004 Dec; 8(6):R398-402. PubMed ID: 15566583
[TBL] [Abstract][Full Text] [Related]
18. Does the tube-compensation function of two modern mechanical ventilators provide effective work of breathing relief?
Maeda Y; Fujino Y; Uchiyama A; Taenaka N; Mashimo T; Nishimura M
Crit Care; 2003 Oct; 7(5):R92-7. PubMed ID: 12974975
[TBL] [Abstract][Full Text] [Related]
19. [Effects of aerosol inhalation on respiratory mechanical parameters under different ventilation patterns and ventilator parameters].
Wang L; Guan C; Qin X; Qu Y
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2018 Nov; 30(11):1036-1040. PubMed ID: 30541641
[TBL] [Abstract][Full Text] [Related]
20. Excessive tidal volume from breath stacking during lung-protective ventilation for acute lung injury.
Pohlman MC; McCallister KE; Schweickert WD; Pohlman AS; Nigos CP; Krishnan JA; Charbeneau JT; Gehlbach BK; Kress JP; Hall JB
Crit Care Med; 2008 Nov; 36(11):3019-23. PubMed ID: 18824913
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]