BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

496 related articles for article (PubMed ID: 15794101)

  • 1. [Exhaled tidal volume is overestimated due to cardiogenic oscillation: effects of ventilator and mode].
    Imanaka H; Takeuchi M; Tachibana K; Takauchi Y; Inamori N; Nishimura M
    Masui; 2005 Mar; 54(3):254-9. PubMed ID: 15794101
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Expiratory tidal volume displayed on Bird 8400 STi can exceed the preset tidal volume due to cardiogenic oscillation: a lung model study.
    Imanaka H; Takeuchi M; Tachibana K; Nishimura M
    J Anesth; 2004; 18(4):313-5. PubMed ID: 15549478
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Exhaled tidal volume overestimation in mechanically ventilated patients with large cardiogenic oscillation.
    Imanaka H; Takeuchi M; Tachibana K; Nishimura M
    Crit Care Med; 2004 Jul; 32(7):1546-9. PubMed ID: 15241100
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
    Tung A; Drum ML; Morgan S
    J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
    Chow LC; Vanderhal A; Raber J; Sola A
    Pediatr Pulmonol; 2002 Sep; 34(3):196-202. PubMed ID: 12203848
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A study of the parameters of the delivered tidal volume. Ventilation on a lung model using the CICERO anesthetic ventilator].
    Schirmer U; Villwock J; Fösel T; Schreiber M; Goertz A; Georgieff M
    Anaesthesist; 1992 Dec; 41(12):785-9. PubMed ID: 1489078
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment].
    Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH
    Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pressure support and pressure assist/control: are there differences? An evaluation of the newest intensive care unit ventilators.
    Williams P; Kratohvil J; Ritz R; Hess DR; Kacmarek RM
    Respir Care; 2000 Oct; 45(10):1169-81. PubMed ID: 11054896
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The impact of closed endotracheal suctioning systems on mechanical ventilator performance.
    El Masry A; Williams PF; Chipman DW; Kratohvil JP; Kacmarek RM
    Respir Care; 2005 Mar; 50(3):345-53. PubMed ID: 15737244
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A laboratory evaluation of 2 mechanical ventilators in the presence of helium-oxygen mixtures.
    Brown MK; Willms DC
    Respir Care; 2005 Mar; 50(3):354-60. PubMed ID: 15737245
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of tidal volume demand on work of breathing during simulated lung-protective ventilation.
    Kallet RH; Alonso JA; Diaz M; Campbell AR; Mackersie RC; Katz JA
    Respir Care; 2002 Aug; 47(8):898-909. PubMed ID: 12162801
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Limiting volume with modern ventilators.
    Wing TJ; Haan L; Ashworth LJ; Anderson J
    Ther Adv Respir Dis; 2015 Jun; 9(3):75-83. PubMed ID: 25801644
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relationship between endotracheal tube leakage and under-reading of tidal volume in neonatal ventilators.
    Mahmoud RA; Fischer HS; Proquitté H; Shalaby HM; Schmalisch G
    Acta Paediatr; 2009 Jul; 98(7):1116-22. PubMed ID: 19432838
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Changes in delivered tidal volume with the addition of carbon dioxide to mechanical ventilation.
    Tobias JD; Miltenberg L
    Paediatr Anaesth; 2009 Mar; 19(3):240-3. PubMed ID: 19143961
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume.
    Al-Majed SI; Thompson JE; Watson KF; Randolph AG
    Crit Care; 2004 Dec; 8(6):R398-402. PubMed ID: 15566583
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does the tube-compensation function of two modern mechanical ventilators provide effective work of breathing relief?
    Maeda Y; Fujino Y; Uchiyama A; Taenaka N; Mashimo T; Nishimura M
    Crit Care; 2003 Oct; 7(5):R92-7. PubMed ID: 12974975
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Effects of aerosol inhalation on respiratory mechanical parameters under different ventilation patterns and ventilator parameters].
    Wang L; Guan C; Qin X; Qu Y
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2018 Nov; 30(11):1036-1040. PubMed ID: 30541641
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Excessive tidal volume from breath stacking during lung-protective ventilation for acute lung injury.
    Pohlman MC; McCallister KE; Schweickert WD; Pohlman AS; Nigos CP; Krishnan JA; Charbeneau JT; Gehlbach BK; Kress JP; Hall JB
    Crit Care Med; 2008 Nov; 36(11):3019-23. PubMed ID: 18824913
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.