198 related articles for article (PubMed ID: 15797084)
1. A new method of temporary epicardial atrioventricular pacing utilizing bipolar pacing leads.
Hasan S; Lewis CT
Ann Thorac Surg; 2005 Apr; 79(4):1384-7; discussion 1387. PubMed ID: 15797084
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of fractal-coated temporary pacing leads in the early postoperative course.
Mellert F; Konietzko P; Schneider C; Gersing E; Kreuz J; Balta O; Preusse CJ; Welz A
Pacing Clin Electrophysiol; 2008 Feb; 31(2):198-206. PubMed ID: 18233973
[TBL] [Abstract][Full Text] [Related]
3. Efficacy of prophylactic epicardial pacing leads in children and young adults.
Cohen MI; Rhodes LA; Spray TL; Gaynor JW
Ann Thorac Surg; 2004 Jul; 78(1):197-202; discussion 202-3. PubMed ID: 15223427
[TBL] [Abstract][Full Text] [Related]
4. [Low pacing thresholds of ventricular pacemaker leads: not a marker for large R-wave amplitudes and high impedance values].
Schuchert A; Bornhoff S; Meinertz T
Z Kardiol; 1995 Dec; 84(12):971-6. PubMed ID: 8578793
[TBL] [Abstract][Full Text] [Related]
5. Feasibility of temporary biventricular pacing in patients with reduced left ventricular function after coronary artery bypass grafting.
Eberhardt F; Hanke T; Heringlake M; Massalme MS; Bechtel M; Misfeld M; Wiegand UK
Pacing Clin Electrophysiol; 2007 Jan; 30 Suppl 1():S50-3. PubMed ID: 17302717
[TBL] [Abstract][Full Text] [Related]
6. Left heart atrial and ventricular epicardial pacing through a left lateral thoracotomy in children: a safe approach with excellent functional and cosmetic results.
Dodge-Khatami A; Kadner A; Dave H; Rahn M; Prêtre R; Bauersfeld U
Eur J Cardiothorac Surg; 2005 Oct; 28(4):541-5. PubMed ID: 16125947
[TBL] [Abstract][Full Text] [Related]
7. Temporary epicardial pacemaker wires: significance of position and electrode type.
Aser R; Orhan C; Niemann B; Roth P; Perepelitsa A; Attmann T; Böning A
Thorac Cardiovasc Surg; 2014 Feb; 62(1):66-9. PubMed ID: 23034875
[TBL] [Abstract][Full Text] [Related]
8. Long-term performance of active-fixation pacing leads: a prospective study.
Kistler PM; Liew G; Mond HG
Pacing Clin Electrophysiol; 2006 Mar; 29(3):226-30. PubMed ID: 16606388
[TBL] [Abstract][Full Text] [Related]
9. Atrial lead location at the Bachmann's bundle region results in a low incidence of far field R-wave sensing.
Lewicka-Nowak E; Kutarski A; Dabrowska-Kugacka A; Rucinski P; Zagozdzon P; Raczak G
Europace; 2008 Feb; 10(2):138-46. PubMed ID: 18192341
[TBL] [Abstract][Full Text] [Related]
10. A simplified technique for implantation of left ventricular epicardial leads for biventricular re-synchronization using video-assisted thoracoscopy (VATS).
Gabor S; Prenner G; Wasler A; Schweiger M; Tscheliessnigg KH; Smolle-Jüttner FM
Eur J Cardiothorac Surg; 2005 Dec; 28(6):797-800. PubMed ID: 16275002
[TBL] [Abstract][Full Text] [Related]
11. Electrical characteristics of low atrial septum pacing compared with right atrial appendage pacing.
de Voogt WG; van Mechelen R; van den Bos AA; Scheffer M; van Hemel NM; Levine PA
Europace; 2005 Jan; 7(1):60-6. PubMed ID: 15670969
[TBL] [Abstract][Full Text] [Related]
12. Twenty years of paediatric cardiac pacing: 515 pacemakers and 480 leads implanted in 292 patients.
Silvetti MS; Drago F; Grutter G; De Santis A; Di Ciommo V; Ravà L
Europace; 2006 Jul; 8(7):530-6. PubMed ID: 16798767
[TBL] [Abstract][Full Text] [Related]
13. Time-limited efficacy of pacing electrodes following open heart surgery.
Kosmas CE; Ryder RG; Poon MJ; Zelenkofske SL; Banka VS
Indian Heart J; 1996; 48(6):681-4. PubMed ID: 9062018
[TBL] [Abstract][Full Text] [Related]
14. Bipolar atrial application of a new temporary pacing lead after cardiac operations.
Breivik K; Engedal H; Resch F; Segadal L; Ohm OJ
J Thorac Cardiovasc Surg; 1983 Apr; 85(4):625-31. PubMed ID: 6834878
[TBL] [Abstract][Full Text] [Related]
15. Long-term performance of coronary sinus leads used for cardiac resynchronization therapy.
Iuliano A; Shopova G; De Simone A; Solimene F; Turco P; Marrazzo N; La Rocca V; Ciardiello C; Agrusta M; Stabile G
Pacing Clin Electrophysiol; 2007 Jan; 30 Suppl 1():S47-9. PubMed ID: 17302716
[TBL] [Abstract][Full Text] [Related]
16. Reliability of different temporary myocardial pacing leads.
Wirtz S; Schulte HD; Winter J; Godehardt E; Kunert J
Thorac Cardiovasc Surg; 1989 Jun; 37(3):163-8. PubMed ID: 2763277
[TBL] [Abstract][Full Text] [Related]
17. Performance evaluation of a right atrial automatic capture verification algorithm using two different sensing configurations.
Sperzel J; Goetze S; Kennergren C; Biffi M; Brooke MJ; Vireca E; Saha S; Schubert B; Butter C
Pacing Clin Electrophysiol; 2009 May; 32(5):579-87. PubMed ID: 19422578
[TBL] [Abstract][Full Text] [Related]
18. Stimulation of the left ventricle through the coronary sinus with a newly developed 'over the wire' lead system--early experiences with lead handling and positioning.
Sack S; Heinzel F; Dagres N; Enger S; Auricchio A; Stellbrink C; Neuzner J; Potty P; Maarse A; Tockman B; Michel U; Erbel R
Europace; 2001 Oct; 3(4):317-23. PubMed ID: 11678391
[TBL] [Abstract][Full Text] [Related]
19. Temporary left ventricular pacing improves haemodynamic performance in patients requiring epicardial pacing post cardiac surgery.
Flynn MJ; McComb JM; Dark JH
Eur J Cardiothorac Surg; 2005 Aug; 28(2):250-3. PubMed ID: 15923120
[TBL] [Abstract][Full Text] [Related]
20. Atrioventricular sequential pacing using transesophageal atrial pacing in combination with a temporary DDD pacemaker for atrial tracking and ventricular pacing.
Roth JV; Huertas R
J Cardiothorac Vasc Anesth; 1995 Jun; 9(3):255-8. PubMed ID: 7669956
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]