BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

740 related articles for article (PubMed ID: 15798243)

  • 1. A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT).
    Scharfetter H; Merwa R; Pilz K
    Physiol Meas; 2005 Apr; 26(2):S307-18. PubMed ID: 15798243
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Solution of the inverse problem of magnetic induction tomography (MIT).
    Merwa R; Hollaus K; Brunner P; Scharfetter H
    Physiol Meas; 2005 Apr; 26(2):S241-50. PubMed ID: 15798237
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of sensors for minimizing the primary signal in planar-array magnetic induction tomography.
    Watson S; Igney CH; Dössel O; Williams RJ; Griffiths H
    Physiol Meas; 2005 Apr; 26(2):S319-31. PubMed ID: 15798244
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Design and performance of a planar-array MIT system with normal sensor alignment.
    Igney CH; Watson S; Williams RJ; Griffiths H; Dössel O
    Physiol Meas; 2005 Apr; 26(2):S263-78. PubMed ID: 15798239
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A multifrequency magnetic induction tomography system using planar gradiometers: data collection and calibration.
    Rosell-Ferrer J; Merwa R; Brunner P; Scharfetter H
    Physiol Meas; 2006 May; 27(5):S271-80. PubMed ID: 16636418
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Induced current magnetic resonance-electrical impedance tomography.
    Ozparlak L; Ider YZ
    Physiol Meas; 2005 Apr; 26(2):S289-305. PubMed ID: 15798242
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysing radio-frequency coil arrays in high-field magnetic resonance imaging by the combined field integral equation method.
    Wang S; Duyn JH
    Phys Med Biol; 2006 Jun; 51(12):3211-29. PubMed ID: 16757872
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Spatial resolution improvement of 3D EIT images by the shrinking sLORETA-FOCUSS algorithm.
    Dong G; Liu H; Bayford RH; Yerworth R; Schimpf PH; Yan W
    Physiol Meas; 2005 Apr; 26(2):S199-208. PubMed ID: 15798233
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Solution of the inverse problem of magnetic induction tomography (MIT) with multiple objects: analysis of detectability and statistical properties with respect to the reconstructed conducting region.
    Merwa R; Brunner P; Missner A; Hollaus K; Scharfetter H
    Physiol Meas; 2006 May; 27(5):S249-59. PubMed ID: 16636415
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electrical conductivity images of biological tissue phantoms in MREIT.
    Oh SH; Lee BI; Woo EJ; Lee SY; Kim TS; Kwon O; Seo JK
    Physiol Meas; 2005 Apr; 26(2):S279-88. PubMed ID: 15798241
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reconstruction of the shape of conductivity spectra using differential multi-frequency magnetic induction tomography.
    Brunner P; Merwa R; Missner A; Rosell J; Hollaus K; Scharfetter H
    Physiol Meas; 2006 May; 27(5):S237-48. PubMed ID: 16636414
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biological tissue characterization by magnetic induction spectroscopy (MIS): requirements and limitations.
    Scharfetter H; Casañas R; Rosell J
    IEEE Trans Biomed Eng; 2003 Jul; 50(7):870-80. PubMed ID: 12848355
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dynamic electrical impedance imaging with the interacting multiple model scheme.
    Kim KY; Kim BS; Kim MC; Kim S; Isaacson D; Newell JC
    Physiol Meas; 2005 Apr; 26(2):S217-33. PubMed ID: 15798235
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rapid polarizing field cycling in magnetic resonance imaging.
    Matter NI; Scott GC; Grafendorfer T; Macovski A; Conolly SM
    IEEE Trans Med Imaging; 2006 Jan; 25(1):84-93. PubMed ID: 16398417
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Phase artefact reduction in magnetic resonance electrical impedance tomography (MREIT).
    Lee BI; Park C; Pyo HC; Kwon O; Woo EJ
    Phys Med Biol; 2006 Oct; 51(20):5277-88. PubMed ID: 17019038
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new decoupling method for quadrature coils in magnetic resonance imaging.
    Hui HT; Li BK; Crozier S
    IEEE Trans Biomed Eng; 2006 Oct; 53(10):2114-6. PubMed ID: 17019876
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Image reconstructions with the rotating RF coil.
    Trakic A; Wang H; Weber E; Li BK; Poole M; Liu F; Crozier S
    J Magn Reson; 2009 Dec; 201(2):186-98. PubMed ID: 19800824
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design and performance issues of RF coils utilized in ultra high field MRI: experimental and numerical evaluations.
    Ibrahim TS; Kangarlu A; Chakeress DW
    IEEE Trans Biomed Eng; 2005 Jul; 52(7):1278-84. PubMed ID: 16041991
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Using the GRID to improve the computation speed of electrical impedance tomography (EIT) reconstruction algorithms.
    Fritschy J; Horesh L; Holder DS; Bayford RH
    Physiol Meas; 2005 Apr; 26(2):S209-15. PubMed ID: 15798234
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Planar gradiometer for magnetic induction tomography (MIT): theoretical and experimental sensitivity maps for a low-contrast phantom.
    Scharfetter H; Rauchenzauner S; Merwa R; Biró O; Hollaus K
    Physiol Meas; 2004 Feb; 25(1):325-33. PubMed ID: 15005326
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 37.