505 related articles for article (PubMed ID: 15798263)
1. Effect of statistical uncertainties on Monte Carlo treatment planning.
Ma CM; Li JS; Jiang SB; Pawlicki T; Xiong W; Qin LH; Yang J
Phys Med Biol; 2005 Mar; 50(5):891-907. PubMed ID: 15798263
[TBL] [Abstract][Full Text] [Related]
2. Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer.
Yang J; Li J; Chen L; Price R; McNeeley S; Qin L; Wang L; Xiong W; Ma CM
Phys Med Biol; 2005 Mar; 50(5):869-78. PubMed ID: 15798261
[TBL] [Abstract][Full Text] [Related]
3. A Monte Carlo-based procedure for independent monitor unit calculation in IMRT treatment plans.
Pisaturo O; Moeckli R; Mirimanoff RO; Bochud FO
Phys Med Biol; 2009 Jul; 54(13):4299-310. PubMed ID: 19531844
[TBL] [Abstract][Full Text] [Related]
4. Toward automatic field selection and planning using Monte Carlo-based direct aperture optimization in modulated electron radiotherapy.
Alexander A; DeBlois F; Seuntjens J
Phys Med Biol; 2010 Aug; 55(16):4563-76. PubMed ID: 20668341
[TBL] [Abstract][Full Text] [Related]
5. Head-and-neck IMRT treatments assessed with a Monte Carlo dose calculation engine.
Seco J; Adams E; Bidmead M; Partridge M; Verhaegen F
Phys Med Biol; 2005 Mar; 50(5):817-30. PubMed ID: 15798257
[TBL] [Abstract][Full Text] [Related]
6. IMRT head and neck treatment planning with a commercially available Monte Carlo based planning system.
Boudreau C; Heath E; Seuntjens J; Ballivy O; Parker W
Phys Med Biol; 2005 Mar; 50(5):879-90. PubMed ID: 15798262
[TBL] [Abstract][Full Text] [Related]
7. A practical Monte Carlo MU verification tool for IMRT quality assurance.
Fan J; Li J; Chen L; Stathakis S; Luo W; Du Plessis F; Xiong W; Yang J; Ma CM
Phys Med Biol; 2006 May; 51(10):2503-15. PubMed ID: 16675866
[TBL] [Abstract][Full Text] [Related]
8. The importance of accurate linear accelerator head modelling for IMRT Monte Carlo calculations.
Reynaert N; Coghe M; De Smedt B; Paelinck L; Vanderstraeten B; De Gersem W; Van Duyse B; De Wagter C; De Neve W; Thierens H
Phys Med Biol; 2005 Mar; 50(5):831-46. PubMed ID: 15798258
[TBL] [Abstract][Full Text] [Related]
9. Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures.
Mavroidis P; Ferreira BC; Shi C; Lind BK; Papanikolaou N
Phys Med Biol; 2007 Jul; 52(13):3817-36. PubMed ID: 17664579
[TBL] [Abstract][Full Text] [Related]
10. Monte Carlo simulation of a medical linear accelerator for radiotherapy use.
Serrano B; Hachem A; Franchisseur E; Hérault J; Marcié S; Costa A; Bensadoun RJ; Barthe J; Gérard JP
Radiat Prot Dosimetry; 2006; 119(1-4):506-9. PubMed ID: 16644964
[TBL] [Abstract][Full Text] [Related]
11. A comparison of Monte Carlo dose calculation denoising techniques.
El Naqa I; Kawrakow I; Fippel M; Siebers JV; Lindsay PE; Wickerhauser MV; Vicic M; Zakarian K; Kauffmann N; Deasy JO
Phys Med Biol; 2005 Mar; 50(5):909-22. PubMed ID: 15798264
[TBL] [Abstract][Full Text] [Related]
12. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
Sikora M; Dohm O; Alber M
Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
[TBL] [Abstract][Full Text] [Related]
13. A preliminary study of in-house Monte Carlo simulations: an integrated Monte Carlo verification system.
Mukumoto N; Tsujii K; Saito S; Yasunaga M; Takegawa H; Yamamoto T; Numasaki H; Teshima T
Int J Radiat Oncol Biol Phys; 2009 Oct; 75(2):571-9. PubMed ID: 19735883
[TBL] [Abstract][Full Text] [Related]
14. A technique for generating phase-space-based Monte Carlo beamlets in radiotherapy applications.
Bush K; Popescu IA; Zavgorodni S
Phys Med Biol; 2008 Sep; 53(18):N337-47. PubMed ID: 18711246
[TBL] [Abstract][Full Text] [Related]
15. Investigation of geometrical and scoring grid resolution for Monte Carlo dose calculations for IMRT.
De Smedt B; Vanderstraeten B; Reynaert N; De Neve W; Thierens H
Phys Med Biol; 2005 Sep; 50(17):4005-19. PubMed ID: 16177526
[TBL] [Abstract][Full Text] [Related]
16. Clinical evaluation of direct aperture optimization when applied to head-and-neck IMRT.
Jones S; Williams M
Med Dosim; 2008; 33(1):86-92. PubMed ID: 18262129
[TBL] [Abstract][Full Text] [Related]
17. EUD-based radiotherapy treatment plan evaluation: incorporating physical and Monte Carlo statistical dose uncertainties.
Cranmer-Sargison G; Zavgorodni S
Phys Med Biol; 2005 Sep; 50(17):4097-109. PubMed ID: 16177533
[TBL] [Abstract][Full Text] [Related]
18. Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm.
Newhauser W; Fontenot J; Zheng Y; Polf J; Titt U; Koch N; Zhang X; Mohan R
Phys Med Biol; 2007 Aug; 52(15):4569-84. PubMed ID: 17634651
[TBL] [Abstract][Full Text] [Related]
19. Monte Carlo simulation of the photon beam characteristics from medical linear accelerators.
Kim HK; Han SJ; Kim JL; Kim BH; Chang SY; Lee JK
Radiat Prot Dosimetry; 2006; 119(1-4):510-3. PubMed ID: 16644954
[TBL] [Abstract][Full Text] [Related]
20. Effect of electron beam obliquity on lateral buildup ratio: a Monte Carlo dosimetry evaluation.
Chow JC; Grigorov GN
Phys Med Biol; 2007 Jul; 52(13):3965-77. PubMed ID: 17664588
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]