These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
194 related articles for article (PubMed ID: 15798300)
1. Modelling the electrical properties of bladder tissue--quantifying impedance changes due to inflammation and oedema. Walker DC; Smallwood RH; Keshtar A; Wilkinson BA; Hamdy FC; Lee JA Physiol Meas; 2005 Jun; 26(3):251-68. PubMed ID: 15798300 [TBL] [Abstract][Full Text] [Related]
2. Modeled current distribution inside the normal and malignant human urothelium using finite element analysis. Keshtkar A; Keshtkar A IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):733-8. PubMed ID: 18270011 [TBL] [Abstract][Full Text] [Related]
3. Electrical impedance spectroscopy (EIS) in the urinary bladder: the effect of inflammation and edema on identification of malignancy. Smallwood RH; Keshtkar A; Wilkinson BA; Lee JA; Hamdy FC IEEE Trans Med Imaging; 2002 Jun; 21(6):708-10. PubMed ID: 12166869 [TBL] [Abstract][Full Text] [Related]
4. The feasibility of computational modelling technique to detect the bladder cancer. Keshtkar A; Mesbahi A; Rasta SH; Keshtkar A Phys Med; 2010 Jan; 26(1):34-7. PubMed ID: 19604712 [TBL] [Abstract][Full Text] [Related]
5. A theoretical study on magnetic induction frequency dependence of phase shift in oedema and haematoma. González CA; Rubinsky B Physiol Meas; 2006 Sep; 27(9):829-38. PubMed ID: 16868349 [TBL] [Abstract][Full Text] [Related]
6. Electrical bioimpedance readings increase with higher pressure applied to the measuring probe. González-Correa CA; Brown BH; Smallwood RH; Walker DC; Bardhan KD Physiol Meas; 2005 Apr; 26(2):S39-47. PubMed ID: 15798245 [TBL] [Abstract][Full Text] [Related]
7. Electrical impedance spectroscopy of the human prostate. Halter RJ; Hartov A; Heaney JA; Paulsen KD; Schned AR IEEE Trans Biomed Eng; 2007 Jul; 54(7):1321-7. PubMed ID: 17605363 [TBL] [Abstract][Full Text] [Related]
8. Body composition modeling in the calf using an equivalent circuit model of multi-frequency bioimpedance analysis. Zhu F; Leonard EF; Levin NW Physiol Meas; 2005 Apr; 26(2):S133-43. PubMed ID: 15798226 [TBL] [Abstract][Full Text] [Related]
9. Prediction of mechanical properties of human trabecular bone by electrical measurements. Sierpowska J; Hakulinen MA; Töyräs J; Day JS; Weinans H; Jurvelin JS; Lappalainen R Physiol Meas; 2005 Apr; 26(2):S119-31. PubMed ID: 15798225 [TBL] [Abstract][Full Text] [Related]
10. Induced current bio-impedance technique for monitoring bone mineral density--a simulation model. Katz S; Zlochiver S; Abboud S Ann Biomed Eng; 2006 Aug; 34(8):1332-42. PubMed ID: 16807787 [TBL] [Abstract][Full Text] [Related]
11. Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes. Gandhi SV; Walker DC; Brown BH; Anumba DO Biomed Eng Online; 2006 Nov; 5():62. PubMed ID: 17125510 [TBL] [Abstract][Full Text] [Related]
12. Monitoring of lung edema using focused impedance spectroscopy: a feasibility study. Mayer M; Brunner P; Merwa R; Scharfetter H Physiol Meas; 2005 Jun; 26(3):185-92. PubMed ID: 15798294 [TBL] [Abstract][Full Text] [Related]
13. Cole electrical impedance model--a critique and an alternative. Grimnes S; Martinsen OG IEEE Trans Biomed Eng; 2005 Jan; 52(1):132-5. PubMed ID: 15651574 [TBL] [Abstract][Full Text] [Related]
14. Effect of esophagus status and catheter configuration on multiple intraluminal impedance measurements. Al-Zaben A; Chandrasekar V Physiol Meas; 2005 Jun; 26(3):229-38. PubMed ID: 15798298 [TBL] [Abstract][Full Text] [Related]
15. Determination of Cole parameters in multiple frequency bioelectrical impedance analysis using only the measurement of impedances. Ward LC; Essex T; Cornish BH Physiol Meas; 2006 Sep; 27(9):839-50. PubMed ID: 16868350 [TBL] [Abstract][Full Text] [Related]
16. Direct reconstruction of tissue parameters from differential multifrequency EIT in vivo. Mayer M; Brunner P; Merwa R; Smolle-Jüttner FM; Maier A; Scharfetter H Physiol Meas; 2006 May; 27(5):S93-101. PubMed ID: 16636423 [TBL] [Abstract][Full Text] [Related]
17. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods. Jaffrin MY; Morel H Med Eng Phys; 2008 Dec; 30(10):1257-69. PubMed ID: 18676172 [TBL] [Abstract][Full Text] [Related]
18. The effect of applied pressure on the electrical impedance of the bladder tissue using small and large probes. Keshtkar A; Keshtkar A J Med Eng Technol; 2008; 32(6):505-11. PubMed ID: 19005965 [TBL] [Abstract][Full Text] [Related]
19. Assessment of 1-lead and 2-lead electrode patterns in electrical impedance endotomography. Fournier-Desseux A; Jossinet J Physiol Meas; 2005 Aug; 26(4):337-49. PubMed ID: 15886430 [TBL] [Abstract][Full Text] [Related]
20. Noninvasive imaging of bioimpedance distribution by means of current reconstruction magnetic resonance electrical impedance tomography. Gao N; He B IEEE Trans Biomed Eng; 2008 May; 55(5):1530-8. PubMed ID: 18440899 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]