137 related articles for article (PubMed ID: 15808018)
1. Isotope dilution-mass spectrometry determination of blood cyanide by headspace gas chromatography.
Dumas P; Gingras G; LeBlanc A
J Anal Toxicol; 2005; 29(1):71-5. PubMed ID: 15808018
[TBL] [Abstract][Full Text] [Related]
2. Specific determination of cyanide in blood by headspace gas chromatography.
Odoul M; Fouillet B; Nouri B; Chambon R; Chambon P
J Anal Toxicol; 1994; 18(4):205-7. PubMed ID: 7967540
[TBL] [Abstract][Full Text] [Related]
3. Determination of cyanide in blood by isotope-dilution gas chromatography-mass spectrometry.
Murphy KE; Schantz MM; Butler TA; Benner BA; Wood LJ; Turk GC
Clin Chem; 2006 Mar; 52(3):458-67. PubMed ID: 16439606
[TBL] [Abstract][Full Text] [Related]
4. Blood cyanide determination in two cases of fatal intoxication: comparison between headspace gas chromatography and a spectrophotometric method.
Gambaro V; Arnoldi S; Casagni E; Dell'acqua L; Pecoraro C; Froldi R
J Forensic Sci; 2007 Nov; 52(6):1401-4. PubMed ID: 18093070
[TBL] [Abstract][Full Text] [Related]
5. Rapid quantitation of cyanide in whole blood by automated headspace gas chromatography.
Calafat AM; Stanfill SB
J Chromatogr B Analyt Technol Biomed Life Sci; 2002 May; 772(1):131-7. PubMed ID: 12016024
[TBL] [Abstract][Full Text] [Related]
6. Determination of cyanide and thiocyanate in blood by gas chromatography and gas chromatography-mass spectrometry.
Kage S; Nagata T; Kudo K
J Chromatogr B Biomed Appl; 1996 Jan; 675(1):27-32. PubMed ID: 8634765
[TBL] [Abstract][Full Text] [Related]
7. Determination of cyanide in whole blood by capillary gas chromatography with cryogenic oven trapping.
Ishii A; Seno H; Watanabe-Suzuki K; Suzuki O; Kumazawa T
Anal Chem; 1998 Nov; 70(22):4873-6. PubMed ID: 9844576
[TBL] [Abstract][Full Text] [Related]
8. Determination of cyanide in blood by reaction head-space gas chromatography.
Felby S
Forensic Sci Med Pathol; 2009; 5(1):39-43. PubMed ID: 19291430
[TBL] [Abstract][Full Text] [Related]
9. Cyanide assay: statistical comparison of a new gas chromatographic calibration method versus the classical spectrophotometric method.
Cardeal ZL; Gallet JP; Astier A; Pradeau D
J Anal Toxicol; 1995; 19(1):31-4. PubMed ID: 7723299
[TBL] [Abstract][Full Text] [Related]
10. An improved method for cyanide determination in blood using solid-phase microextraction and gas chromatography/mass spectrometry.
Frison G; Zancanaro F; Favretto D; Ferrara SD
Rapid Commun Mass Spectrom; 2006; 20(19):2932-8. PubMed ID: 16941546
[TBL] [Abstract][Full Text] [Related]
11. [Determination of 1, 4-dioxane in aerosol cosmetic by new isotope dilution-headspace gas chromatography-mass spectrometry].
Rong W; Zhu M; Ji W; Liu H; Huo Z; Song N
Wei Sheng Yan Jiu; 2020 Mar; 49(2):280-284. PubMed ID: 32290946
[TBL] [Abstract][Full Text] [Related]
12. Modified congener analysis: Quantification of cyanide in whole blood, other body fluids, and diverse beverages.
Sundermann TR; Schmitt G; Bartel M
Drug Test Anal; 2021 Feb; 13(2):412-418. PubMed ID: 32939996
[TBL] [Abstract][Full Text] [Related]
13. [Determination of blood cyanide using head-space gas chromatography with electron capture detection].
Maseda C; Matsubara K; Hasegawa M; Akane A; Shiono H
Nihon Hoigaku Zasshi; 1990 Apr; 44(2):131-6. PubMed ID: 2169555
[TBL] [Abstract][Full Text] [Related]
14. Rapid quantitation of cyanide in blood by gas chromatography.
McAuley F; Reive DS
J Anal Toxicol; 1983; 7(5):213-5. PubMed ID: 6645399
[TBL] [Abstract][Full Text] [Related]
15. Determination of cyanide and volatile alkylnitriles in whole blood by headspace solid-phase microextraction and gas chromatography with nitrogen phosphorus detection.
Boadas-Vaello P; Jover E; Llorens J; Bayona JM
J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Jul; 870(1):17-21. PubMed ID: 18541461
[TBL] [Abstract][Full Text] [Related]
16. Improved gas chromatography with electron-capture detection using a reaction pre-column for the determination of blood cyanide: a higher content in the left ventricle of fire victims.
Maseda C; Matsubara K; Shiono H
J Chromatogr; 1989 May; 490(2):319-27. PubMed ID: 2768405
[TBL] [Abstract][Full Text] [Related]
17. Quantitative analysis of polybrominated diphenyl ethers in adipose tissue, human serum and foodstuff samples by gas chromatography with ion trap tandem mass spectrometry and isotope dilution.
Gómara B; Herrero L; Bordajandi LR; González MJ
Rapid Commun Mass Spectrom; 2006; 20(2):69-74. PubMed ID: 16331726
[TBL] [Abstract][Full Text] [Related]
18. Ultratrace determination of total and available cyanides in industrial wastewaters through a rapid headspace-based sample preparation and gas chromatography with nitrogen phosphorous detection analysis.
Marton D; Tapparo A; Di Marco VB; Repice C; Giorio C; Bogialli S
J Chromatogr A; 2013 Jul; 1300():209-16. PubMed ID: 23522617
[TBL] [Abstract][Full Text] [Related]
19. Determination of cyanide and thiocyanate in biological fluids by gas chromatography-mass spectrometry.
Thomson I; Anderson RA
J Chromatogr; 1980 Feb; 188(2):357-62. PubMed ID: 7380931
[TBL] [Abstract][Full Text] [Related]
20. Simultaneous determination of cyanide and thiocyanate in plasma by chemical ionization gas chromatography mass-spectrometry (CI-GC-MS).
Bhandari RK; Oda RP; Youso SL; Petrikovics I; Bebarta VS; Rockwood GA; Logue BA
Anal Bioanal Chem; 2012 Nov; 404(8):2287-94. PubMed ID: 22941221
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]