These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 15808640)

  • 1. Use of perfusion parameters in predicting outcomes of machine-preserved kidneys.
    Mozes MF; Skolek RB; Korf BC
    Transplant Proc; 2005; 37(1):350-1. PubMed ID: 15808640
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The hazards of basing acceptance of cadaveric renal allografts on pulsatile perfusion parameters alone.
    Sonnenday CJ; Cooper M; Kraus E; Gage F; Handley C; Montgomery RA
    Transplantation; 2003 Jun; 75(12):2029-33. PubMed ID: 12829906
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prostaglandin E1 influences pulsatile preservation characteristics and early graft function in expanded criteria donor kidneys.
    Polyak MM; Arrington BO; Stubenbord WT; Kapur S; Kinkhabwala M
    J Surg Res; 1999 Jul; 85(1):17-25. PubMed ID: 10383833
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Can machine perfusion decrease the likelihood of discard among biopsied kidneys?
    Cho YW; Bunnapradist S; Cho ES; Stadtler M; Simmons V; Locke J; Mone T; Mendez R; Hutchinson IV; Gill J; Shah T
    Transplant Proc; 2008 May; 40(4):1029-31. PubMed ID: 18555107
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Role of machine perfusion preservation in kidney transplantation from non-heartbeating donors.
    Matsuno N; Sakurai E; Uchiyama M; Kozaki K; Miyamoto K; Kozaki M; Nagao T
    Clin Transplant; 1998 Feb; 12(1):1-4. PubMed ID: 9541415
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of pulsatile perfusion preservation on outcomes in kidney transplantation from expanded criteria donors.
    Stratta RJ; Moore PS; Farney AC; Rogers J; Hartmann EL; Reeves-Daniel A; Gautreaux MD; Iskandar SS; Adams PL
    J Am Coll Surg; 2007 May; 204(5):873-82; discussion 882-4. PubMed ID: 17481502
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Is pulsatile perfusion necessary for renal transplantation engrafting kidneys from cardiac death donors?
    Kusaka M; Kubota Y; Sasaki H; Maruyama T; Hayakawa K; Shiroki R; Hoshinaga K
    Transplant Proc; 2006 Dec; 38(10):3388-9. PubMed ID: 17175279
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prognostic utility of hypothermic machine perfusion in deceased donor renal transplantation.
    Patel SK; Pankewycz OG; Nader ND; Zachariah M; Kohli R; Laftavi MR
    Transplant Proc; 2012 Sep; 44(7):2207-12. PubMed ID: 22974956
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of pulsatile perfusion on postoperative outcome of kidneys from controlled donors after cardiac death.
    Plata-Munoz JJ; Muthusamy A; Quiroga I; Contractor HH; Sinha S; Vaidya A; Darby C; Fuggle SV; Friend PJ
    Transpl Int; 2008 Sep; 21(9):899-907. PubMed ID: 18444944
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Perfusion Parameters of Donation After Cardiac Death Kidneys Predict Early Transplant Outcomes Based on Expanded Criteria Donor Designation.
    Tai Q; Xue W; Ding X; Tian P; Xiang H; Feng X; Yan H; Hou J
    Transplant Proc; 2018; 50(1):79-84. PubMed ID: 29407336
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microscopic intrarenal particles after pulsatile machine preservation do not adversely affect outcomes after renal transplantation.
    Guarrera JV; Nasr SH; Reverte CM; Samstein B; Brown T; Balachandran V; Samuels MJ; Kelly J; Hardy MA; Markowitz GS; D'Agati VD; Ratner LE
    Transplant Proc; 2006 Dec; 38(10):3384-7. PubMed ID: 17175278
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metabolomic analysis of perfusate during hypothermic machine perfusion of human cadaveric kidneys.
    Guy AJ; Nath J; Cobbold M; Ludwig C; Tennant DA; Inston NG; Ready AR
    Transplantation; 2015 Apr; 99(4):754-9. PubMed ID: 25222017
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Machine perfusion as a tool to select kidneys recovered from uncontrolled donors after cardiac death.
    Reznik ON; Bagnenko SF; Loginov IV; Iljina VA; Ananyev AN; Eremich SV; Moysyuk YG
    Transplant Proc; 2008 May; 40(4):1023-6. PubMed ID: 18555105
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modulating biochemical perturbations during 72-hour machine perfusion of kidneys: role of preservation solution.
    Baicu SC; Taylor MJ; Brockbank KG
    Cryobiology; 2007 Feb; 54(1):114-20. PubMed ID: 17196191
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Outcomes of transplantation using kidneys from donors meeting expanded criteria in Australia and New Zealand, 1991 to 2005.
    Collins MG; Chang SH; Russ GR; McDonald SP
    Transplantation; 2009 Apr; 87(8):1201-9. PubMed ID: 19384167
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An in vivo autotransplant model of renal preservation: cold storage versus machine perfusion in the prevention of ischemia/reperfusion injury.
    La Manna G; Conte D; Cappuccilli ML; Nardo B; D'Addio F; Puviani L; Comai G; Bianchi F; Bertelli R; Lanci N; Donati G; Scolari MP; Faenza A; Stefoni S
    Artif Organs; 2009 Jul; 33(7):565-70. PubMed ID: 19566736
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The protective effect of methyl prednisolone on the machine-preserved kidney.
    McCabe RE; Lattes CG; Lorieo DR; Hashim GA; Fitzpatrick HF
    Am Surg; 1980 Jun; 46(6):335-9. PubMed ID: 6994528
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Experience in renal and extrarenal transplantation with donation after cardiac death donors with selective use of extracorporeal support.
    Farney AC; Singh RP; Hines MH; Rogers J; Hartmann EL; Reeves-Daniel A; Gautreaux MD; Iskandar SS; Adams PL; Stratta RJ
    J Am Coll Surg; 2008 May; 206(5):1028-37; discussion 1037. PubMed ID: 18471749
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Illinois statewide dual kidney transplantation experience--are we appropriately selecting kidneys?
    Hugen CM; Polcari AJ; Skolek R; Mozes MF; Milner JE
    J Urol; 2011 Sep; 186(3):996-1000. PubMed ID: 21791348
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effectiveness of machine perfusion preservation as a viability determination method for kidneys procured from non-heart-beating donors.
    Matsuno N; Sakurai E; Tamaki I; Furuhashi K; Saito A; Zhang S; Kozaki K; Shimada A; Miyamoto K; Kozaki M
    Transplant Proc; 1994 Aug; 26(4):2421-2. PubMed ID: 8066794
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.