BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 15820490)

  • 1. Comparison of different cyclosporine immunoassays to monitor C0 and C2 blood levels from kidney transplant recipients: not simply overestimation.
    Cattaneo D; Zenoni S; Murgia S; Merlini S; Baldelli S; Perico N; Gotti E; Ottomano C; Crippa A; Remuzzi G
    Clin Chim Acta; 2005 May; 355(1-2):153-64. PubMed ID: 15820490
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of cyclosporine concentrations 2 hours post-dose determined using 3 different methods and trough level in pediatric renal transplantation.
    Rodríguez E; Delucchi MA; Cano F; Valdebenito S; Castillo MC; Villegas R
    Transplant Proc; 2005 Oct; 37(8):3354-7. PubMed ID: 16298594
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of measured trough levels and abbreviated AUC estimation by limited sampling strategies for monitoring mycophenolic acid exposure in stable heart transplant patients receiving cyclosporin A-containing and cyclosporin A-free immunosuppressive regimens.
    Dösch AO; Ehlermann P; Koch A; Remppis A; Katus HA; Dengler TJ
    Clin Ther; 2006 Jun; 28(6):893-905. PubMed ID: 16860172
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Preliminary evaluation of a new chemiluminescence assay (Liaison Cyclosporine; DiaSorin Laboratories) allowing both C0 and C2 cyclosporine levels determination: comparison with RIA method.
    Olejnik Y; Elaerts S; Bonardet A; Chong G; Mourad G; Cristol JP; Dupuy AM
    Transplant Proc; 2005; 37(1):172-4. PubMed ID: 15808584
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calcineurin Inhibitor Determination in Whole Blood With the RXL Dimension Analyzer: A Useful Tool for Immunosuppressive Drug Monitoring.
    Ventura E; Bonardet A; Pageaux GP; Mourad G; Cristol JP
    Transplant Proc; 2009 Mar; 41(2):707-9. PubMed ID: 19328963
    [TBL] [Abstract][Full Text] [Related]  

  • 6. C2 monitoring in maintenance renal transplant recipients: is it worthwhile?
    Midtvedt K; Fauchald P; Bergan S; Høieggen A; Hallan S; Svarstad E; Bergrem H; Eriksen BO; Pfeffer PF; Dalen I; Leivestad T
    Transplantation; 2003 Oct; 76(8):1236-8. PubMed ID: 14578761
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evolution of the absorption profile of cyclosporine A in renal transplant recipients: a longitudinal study of the de novo and maintenance phases.
    Büchler M; Chadban S; Cole E; Midtvedt K; Thervet E; Prestele H; Keown P
    Nephrol Dial Transplant; 2006 Jan; 21(1):197-202. PubMed ID: 16204301
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cyclosporine monitoring in renal transplant recipients with induction therapy: C2 levels in patients monitored on C0.
    Loichot C; Bentue-Ferrer D; Bernard N; Bonardet A; Boulieu R; Kergueris MF; Paintaud G; Peytavin G; Simon N; Marquet P;
    Fundam Clin Pharmacol; 2006 Feb; 20(1):91-6. PubMed ID: 16448399
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Limited sampling strategy for cyclosporine (Neoral) area under the curve monitoring in pediatric kidney transplant recipients.
    Strong DK; Lai A; Primmett D; White CT; Lirenman DS; Carter JE; Hurley RM; Virji M; Ensom MH
    Pediatr Transplant; 2005 Oct; 9(5):566-73. PubMed ID: 16176411
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Advantages of C2 monitoring to avoid acute rejection in pediatric heart transplant recipients.
    Schubert S; Abdul-Khaliq H; Lehmkuhl HB; Hübler M; Abd El Rahman MY; Miera O; Ewert P; Weng Y; Wei H; Krüdewagen B; Hetzer R; Berger F
    J Heart Lung Transplant; 2006 Jun; 25(6):619-25. PubMed ID: 16730566
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Limitations of cyclosporine C2 monitoring in pediatric heart transplant recipients.
    Hmiel SP; Canter C; Shepherd R; Lassa-Claxton S; Nadler M
    Pediatr Transplant; 2007 Aug; 11(5):524-9. PubMed ID: 17631021
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Association between cyclosporine concentrations at 2 hours post-dose and clinical outcomes in de novo lung transplant recipients.
    Akhlaghi F; Gonzalez L; Trull AK
    J Heart Lung Transplant; 2005 Dec; 24(12):2120-8. PubMed ID: 16364860
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of diltiazem on the pharmacokinetics of microemulsion cyclosporine A in renal transplantation.
    Bunnag S; Vareesangthip K; Ong-ajyooth L
    J Med Assoc Thai; 2006 Aug; 89 Suppl 2():S228-34. PubMed ID: 17044476
    [TBL] [Abstract][Full Text] [Related]  

  • 14. C2 is superior to C0 as predictor of renal toxicity and rejection risk profile in stable heart transplant recipients.
    Caforio AL; Tona F; Piaserico S; Gambino A; Feltrin G; Fortina AB; Angelini A; Alaibac M; Bontorin M; Calzolari D; Peserico A; Thiene G; Iliceto S; Gerosa G
    Transpl Int; 2005 Jan; 18(1):116-24. PubMed ID: 15612993
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of cyclosporine pharmacokinetic parameters to facilitate conversion from C0 to C2 monitoring in heart transplant recipients.
    Davies RA; Veinot JP; Williams K; Haddad H; Baker A; Donaldson J; Pugliese C; Struthers C; Masters RG; Hendry PJ; Mesana T
    Transplant Proc; 2007 Dec; 39(10):3334-9. PubMed ID: 18089382
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monitoring of C0 and C2 blood concentrations of cyclosporine on the Roche Hitachi 902 analyzer.
    Yargui L; Berhoune A
    Transplant Proc; 2009 Nov; 41(9):3713-9. PubMed ID: 19917373
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Early cyclosporine C0 and C2 monitoring in de novo kidney transplant patients: a prospective randomized single-center pilot study.
    Kyllönen LE; Salmela KT
    Transplantation; 2006 Apr; 81(7):1010-5. PubMed ID: 16612277
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of liver function in renal transplant recipients undergoing C2-monitoring for cyclosporine.
    Hecking M; Kainz A; Schillinger M; Posch C; Birsan T; Rasoul-Rockenschaub S; Böhmig GA; Schmaldienst S; Watschinger B; Hörl WH; Mühlbacher F; Säemann MD
    Transpl Int; 2008 Mar; 21(3):223-33. PubMed ID: 17903183
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of cyclosporine A in rat tissues and human kidney transplant biopsies--a method suitable for small (<1 mg) samples.
    Noll BD; Coller JK; Somogyi AA; Morris RG; Russ GR; Hesselink DA; van Gelder T; Sallustio BC
    Ther Drug Monit; 2011 Dec; 33(6):688-93. PubMed ID: 22105584
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pharmacokinetic monitoring of intravenous cyclosporine A in pediatric stem-cell transplant recipients. The trough level is not enough.
    Schrauder A; Saleh S; Sykora KW; Hoy H; Welte K; Boos J; Hempel G; Grigull L
    Pediatr Transplant; 2009 Jun; 13(4):444-50. PubMed ID: 18482216
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.