  • 1. Acute locking in revision total knee arthroplasty due to disengagement of the locking screw.
    Nadkarni JB; Carden DG
    Knee Surg Sports Traumatol Arthrosc; 2005 Apr; 13(3):190-2. PubMed ID: 15824933
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection of locking bolt loosening in the stem-condyle junction of a modular femoral stem in revision total knee arthroplasty.
    Ahn JM; Suh JT
    J Arthroplasty; 2010 Jun; 25(4):660.e11-3. PubMed ID: 19682838
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Screw migration from total knee prostheses requiring subsequent surgery.
    Shah SN; Schurman DJ; Goodman SB
    J Arthroplasty; 2002 Oct; 17(7):951-4. PubMed ID: 12375258
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Migration of polyethylene fixation screw after total knee arthroplasty.
    Cho WS; Youm YS
    J Arthroplasty; 2009 Aug; 24(5):825.e5-9. PubMed ID: 19026518
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Massive femoral osteolytic lesion secondary to disengagement of a total knee tibial locking pin: case report.
    Sathappan SS; Capeci C; Teicher M; Di Cesare PE
    J Knee Surg; 2007 Jul; 20(3):241-4. PubMed ID: 17665788
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Disengagement of a locking screw from a modular stem in revision total knee arthroplasty. A report of three cases.
    Westrich GH; Hidaka C; Windsor RE
    J Bone Joint Surg Am; 1997 Feb; 79(2):254-8. PubMed ID: 9052549
    [No Abstract]   [Full Text] [Related]  

  • 7. Recurrent patella loosening and extra-articular migration after TKA.
    Jacobs E; Feczko P; Emans P
    J Knee Surg; 2013 Dec; 26 Suppl 1():S100-2. PubMed ID: 23288755
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Disassembly of threaded junction between stem extension and femoral component in a total stabilizer revision total knee arthroplasty.
    Lee SC; Nam CH; Jung KA; Lee JH; Ahn HS; Park HY
    Knee; 2014 Mar; 21(2):628-30. PubMed ID: 24508094
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Five cases of failure of the tibial polyethylene insert locking mechanism in one design of constrained knee arthroplasty.
    Rapuri VR; Clarke HD; Spangehl MJ; Beauchamp CP
    J Arthroplasty; 2011 Sep; 26(6):976.e21-4. PubMed ID: 20801615
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contemporary failure aetiologies of the primary, posterior-stabilised total knee arthroplasty.
    Abdel MP; Ledford CK; Kobic A; Taunton MJ; Hanssen AD
    Bone Joint J; 2017 May; 99-B(5):647-652. PubMed ID: 28455474
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Does the total condylar 3 constrained knee prosthesis predispose to failure of revision total knee replacement?
    Rodriguez JA; Shahane S; Rasquinha VJ; Ranawat CS
    J Bone Joint Surg Am; 2003; 85-A Suppl 4():153-6. PubMed ID: 14652408
    [No Abstract]   [Full Text] [Related]  

  • 12. Three Cases of Femoral Stem Failure in Rotating Hinge Revision Total Knee Arthroplasty: Causes and Surgical Considerations.
    Sandiford NA; Phillips JR; Back DL; Toms AD
    Clin Orthop Surg; 2018 Jun; 10(2):260-264. PubMed ID: 29854352
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Johnson-Elloy (Accord) total knee replacement. Poor results at 8 to 12 years.
    Norton MR; Vhadra RK; Timperley AJ
    J Bone Joint Surg Br; 2002 Aug; 84(6):852-5. PubMed ID: 12211676
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Failure of tibial polyethylene insert locking mechanism in posterior stabilized arthroplasty.
    Thienpont E
    Knee Surg Sports Traumatol Arthrosc; 2013 Dec; 21(12):2685-8. PubMed ID: 22547247
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Knee revision arthroplasty : cementless, metaphyseal fixation with sleeves].
    Graichen H; Strauch M; Scior W; Morgan-Jones R
    Oper Orthop Traumatol; 2015 Feb; 27(1):24-34. PubMed ID: 25620192
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Failure of the Stem-Condyle Junction of a Modular Femoral Stem in Revision Total Knee Arthroplasty.
    Boe CC; Fehring KA; Trousdale RT
    Am J Orthop (Belle Mead NJ); 2015 Oct; 44(10):E401-3. PubMed ID: 26447420
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Failure at the taper lock of a modular stemmed femoral implant in revision knee arthroplasty. A report of two cases and a retrieval analysis.
    Issack PS; Cottrell JM; Delgado S; Wright TM; Sculco TP; Su EP
    J Bone Joint Surg Am; 2007 Oct; 89(10):2271-4. PubMed ID: 17908906
    [No Abstract]   [Full Text] [Related]  

  • 18. Arthroscopy after dysfunctional total knee arthroplasty: two cases with peg fracture of the polyethylene insert.
    Krüger T; Reichel H; Decker T; Hein W
    Arthroscopy; 2000 Nov; 16(8):E21. PubMed ID: 11078554
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fracture of the tibial spine of a Total Condylar III knee prosthesis secondary to malrotation of the femoral component.
    Lombardi AV; Mallory TH; Fada RA; Adams JB; Kefauver CA
    Am J Knee Surg; 2001; 14(1):55-9. PubMed ID: 11216721
    [No Abstract]   [Full Text] [Related]  

  • 20. Complete dislodgement of a femoral component of a knee arthroplasty and expulsion through an infected sinus.
    Chatterji U; Almedghio S
    J Arthroplasty; 2012 Mar; 27(3):494.e17-8. PubMed ID: 21889872
    [TBL] [Abstract][Full Text] [Related]  