BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

499 related articles for article (PubMed ID: 15824948)

  • 21. Endoscopic ultrasound-guided tissue sampling: How can we improve the results?
    Alper E; Onur İ; Arabul M; Ünsal B
    Turk J Gastroenterol; 2016 Jan; 27(1):1-3. PubMed ID: 26728860
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A prospective, randomized trial comparing 25-gauge and 22-gauge needles for endoscopic ultrasound-guided fine needle aspiration of pancreatic masses.
    Lee JK; Lee KT; Choi ER; Jang TH; Jang KT; Lee JK; Lee KH
    Scand J Gastroenterol; 2013 Jun; 48(6):752-7. PubMed ID: 23600919
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Systematic Review and Meta-Analysis of Diagnostic Accuracy of Endoscopic Ultrasound (EUS)-Guided Fine-Needle Aspiration (FNA) Using 22-gauge and 25-gauge Needles for Pancreatic Masses.
    Tian G; Bao H; Li J; Jiang T
    Med Sci Monit; 2018 Nov; 24():8333-8341. PubMed ID: 30452433
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Endoscopic Ultrasound-guided Sampling of Solid Pancreatic Lesions: A Comparative Analysis of 25 Gauge
    Siddique DA; Rahal MA; Trevino K; Wu HH; Al-Haddad MA
    Anticancer Res; 2020 Oct; 40(10):5845-5851. PubMed ID: 32988914
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses.
    Park SW; Chung MJ; Lee SH; Lee HS; Lee HJ; Park JY; Park SW; Song SY; Kim H; Chung JB; Bang S
    PLoS One; 2016; 11(5):e0154401. PubMed ID: 27149404
    [TBL] [Abstract][Full Text] [Related]  

  • 26. EUS - Fine- Needle Aspiration Biopsy (FNAB) in the Diagnosis of Pancreatic Adenocarcinoma: A Review.
    Kalogeraki A; Papadakis GZ; Tamiolakis D; Karvela-Kalogeraki I; Karvelas-Kalogerakis M; Segredakis J; Papadakis M; Moustou E; Datseri G; Tzardi M
    Rom J Intern Med; 2016; 54(1):24-30. PubMed ID: 27141567
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Endosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses.
    Harewood GC; Wiersema MJ
    Am J Gastroenterol; 2002 Jun; 97(6):1386-91. PubMed ID: 12094855
    [TBL] [Abstract][Full Text] [Related]  

  • 28. EUS-guided FNA of solid pancreatic masses: a prospective, randomized trial comparing 22-gauge and 25-gauge needles.
    Siddiqui UD; Rossi F; Rosenthal LS; Padda MS; Murali-Dharan V; Aslanian HR
    Gastrointest Endosc; 2009 Dec; 70(6):1093-7. PubMed ID: 19640524
    [TBL] [Abstract][Full Text] [Related]  

  • 29. EUS-guided fine needle aspiration with and without trucut biopsy of pancreatic masses.
    Shah SM; Ribeiro A; Levi J; Jorda M; Rocha-Lima C; Sleeman D; Hamilton-Nelson K; Ganjei-Azar P; Barkin J
    JOP; 2008 Jul; 9(4):422-30. PubMed ID: 18648133
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Prospective evaluation of the optimal number of 25-gauge needle passes for endoscopic ultrasound-guided fine-needle aspiration biopsy of solid pancreatic lesions in the absence of an onsite cytopathologist.
    Suzuki R; Irisawa A; Bhutani MS; Hikichi T; Takagi T; Sato A; Sato M; Ikeda T; Watanabe K; Nakamura J; Tasaki K; Obara K; Ohira H
    Dig Endosc; 2012 Nov; 24(6):452-6. PubMed ID: 23078439
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of 19- and 22-gauge needles in EUS-guided fine needle aspiration in patients with mediastinal masses and lymph nodes.
    Songür N; Songür Y; Bırcan S; Kapucuoğlu N
    Turk J Gastroenterol; 2011 Oct; 22(5):472-8. PubMed ID: 22234753
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Prospective study of a Trucut needle for performing EUS-guided biopsy with EUS-guided FNA rescue.
    Ginès A; Wiersema MJ; Clain JE; Pochron NL; Rajan E; Levy MJ
    Gastrointest Endosc; 2005 Oct; 62(4):597-601. PubMed ID: 16185976
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25 gauge EUS-FNA needles in solid masses.
    Vilmann P; Săftoiu A; Hollerbach S; Skov BG; Linnemann D; Popescu CF; Wellmann A; Gorunescu F; Clementsen P; Freund U; Flemming P; Hassan H; Gheonea DI; Streba L; Ioncică AM; Streba CT
    Scand J Gastroenterol; 2013 Jul; 48(7):877-83. PubMed ID: 23795663
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Endoscopic ultrasound and fine needle aspiration in chronic pancreatitis: differential diagnosis between pseudotumoral masses and pancreatic cancer.
    Ardengh JC; Lopes CV; Campos AD; Pereira de Lima LF; Venco F; Módena JL
    JOP; 2007 Jul; 8(4):413-21. PubMed ID: 17625292
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Endosonographically guided transduodenal and transgastral fine-needle aspiration puncture of focal pancreatic lesions.
    Wegener M; Pfaffenbach B; Adamek RJ
    Bildgebung; 1995 Jun; 62(2):110-5. PubMed ID: 7663134
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The cellularity yield of three different 22-gauge endoscopic ultrasound fine needle aspiration needles.
    Othman MO; Abdelfatah MM; Padilla O; Hussinat M; Elhanafi S; Eloliby M; Torabi A; Hakim N; Boman DA
    Diagn Cytopathol; 2017 May; 45(5):426-432. PubMed ID: 28261978
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Blinded prospective comparison of the performance of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of the pancreas and peri-pancreatic lesions.
    Lee JH; Stewart J; Ross WA; Anandasabapathy S; Xiao L; Staerkel G
    Dig Dis Sci; 2009 Oct; 54(10):2274-81. PubMed ID: 19669880
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Endoscopic ultrasound-guided fine-needle aspiration in focal pancreatic lesions: a prospective intraindividual comparison of two needle assemblies.
    Fritscher-Ravens A; Topalidis T; Bobrowski C; Krause C; Thonke E; Jäckle S; Soehendra N
    Endoscopy; 2001 Jun; 33(6):484-90. PubMed ID: 11437040
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Endosonography-guided biopsy of mediastinal and pancreatic tumors.
    Hünerbein M; Dohmoto M; Haensch W; Schlag PM
    Endoscopy; 1998 Jan; 30(1):32-6. PubMed ID: 9548041
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of 20-gauge Procore® and 22-gauge Acquire® needles for EUS-FNB of solid pancreatic masses: an observational study.
    Karsenti D; Tharsis G; Zeitoun JD; Denis P; Perrot B; Coelho J; Bellaiche G; Charbit L; Hakoune JJ; Doumet S; Sion-Rohart E; Cavicchi M; Zago J
    Scand J Gastroenterol; 2019 Apr; 54(4):499-505. PubMed ID: 31067140
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 25.