These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
749 related articles for article (PubMed ID: 15827399)
1. Identification of sentinel lymph node in stage I-II breast cancer with lymphoscintigraphy and surgical gamma probe: comparison of Tc-99m MIBI and Tc-99m sulfur colloid. Arcan P; Ibis E; Aras G; Cam R; Küçük NO Clin Nucl Med; 2005 May; 30(5):317-21. PubMed ID: 15827399 [TBL] [Abstract][Full Text] [Related]
2. Lymphatic drainage patterns on early versus delayed breast lymphoscintigraphy performed after injection of filtered Tc-99m sulfur colloid in breast cancer patients undergoing sentinel lymph node biopsy. Babiera GV; Delpassand ES; Breslin TM; Ross MI; Ames FC; Singletary SE; Kuerer HM; Feig BW; Meric-Bernstam F; Hunt KK Clin Nucl Med; 2005 Jan; 30(1):11-5. PubMed ID: 15604959 [TBL] [Abstract][Full Text] [Related]
3. Identification of sentinel lymph node in breast cancer by lymphoscintigraphy and surgical gamma probe with peritumoral injection of scintimammographic agent "99mTc MIbI". Aras G; Arican P; Cam R; Küçük NO; Ibiş E; Tüzüner A; Soylu A Ann Nucl Med; 2002 Apr; 16(2):121-6. PubMed ID: 12043906 [TBL] [Abstract][Full Text] [Related]
4. Use of low-dose technetium Tc 99m sulfur colloid to locate sentinel lymph nodes in melanoma of the head and neck: preliminary study. Rasgon BM Laryngoscope; 2001 Aug; 111(8):1366-72. PubMed ID: 11568570 [TBL] [Abstract][Full Text] [Related]
5. The use of periareolar intradermal Tc-99m tin colloid and peritumoral intraparenchymal isosulfan blue dye injections for determination of the sentinel lymph node. Argon AM; Duygun U; Acar E; Daglioz G; Yenjay L; Zekioglu O; Kapkac M Clin Nucl Med; 2006 Dec; 31(12):795-800. PubMed ID: 17117076 [TBL] [Abstract][Full Text] [Related]
6. Preoperative lymphoscintigraphy during lymphatic mapping for breast cancer: improved sentinel node imaging using subareolar injection of technetium 99m sulfur colloid. Kern KA; Rosenberg RJ J Am Coll Surg; 2000 Nov; 191(5):479-89. PubMed ID: 11085727 [TBL] [Abstract][Full Text] [Related]
7. Concordance and validation study of sentinel lymph node biopsy for breast cancer using subareolar injection of blue dye and technetium 99m sulfur colloid. Kern KA J Am Coll Surg; 2002 Oct; 195(4):467-75. PubMed ID: 12375751 [TBL] [Abstract][Full Text] [Related]
8. Retrospective analysis of sentinel node localization in multifocal, multicentric, palpable, or nonpalpable breast cancer. Kumar R; Jana S; Heiba SI; Dakhel M; Axelrod D; Siegel B; Bernik S; Mills C; Wallack M; Abdel-Dayem HM J Nucl Med; 2003 Jan; 44(1):7-10. PubMed ID: 12515869 [TBL] [Abstract][Full Text] [Related]
9. Sentinel lymph node identification with radiopharmaceuticals in patients with breast cancer: a comparison of 99mTc-tin colloid and 99mTc-phytate efficiency. Seok JW; Choi YS; Chong S; Kwon GY; Chung YJ; Kim BG; Park SJ Breast Cancer Res Treat; 2010 Jul; 122(2):453-7. PubMed ID: 20532977 [TBL] [Abstract][Full Text] [Related]
10. Periareolar injection for localization of sentinel nodes in breast cancer patients. Ellis RL; Seifert PJ; Neal CE; Pavolka KR; Mann JL; Malafa MP; Wichterman KA; Ross DS; Dunnington GL Breast J; 2004; 10(2):94-100. PubMed ID: 15009034 [TBL] [Abstract][Full Text] [Related]
11. The value of combined peritumoral and subdermal injection techniques for lymphoscintigraphy in detection of sentinel lymph node in breast cancer. Sanli Y; Berberoglu K; Turkmen C; Ozmen V; Muslumanoglu M; Igci A; Asoglu O; Kecer M; Tuzlali S; Cantez S; Mudun A Clin Nucl Med; 2006 Nov; 31(11):690-3. PubMed ID: 17053386 [TBL] [Abstract][Full Text] [Related]
12. Dye- and gamma probe-guided sentinel lymph node biopsy in breast cancer patients: using patent blue dye and technetium-99m-labeled human serum albumin. Tsugawa K; Noguchi M; Miwa K; Bando E; Yokoyama K; Nakajima K; Michigishi T; Tonami N; Minato H; Nonomura A Breast Cancer; 2000 Jan; 7(1):87-94. PubMed ID: 11029778 [TBL] [Abstract][Full Text] [Related]
13. Sentinel lymph node biopsy in breast cancer: unfiltered radioisotope is superior to filtered. Linehan DC; Hill AD; Tran KN; Yeung H; Yeh SD; Borgen PI; Cody HS J Am Coll Surg; 1999 Apr; 188(4):377-81. PubMed ID: 10195721 [TBL] [Abstract][Full Text] [Related]
14. Failure predictors of the sentinel lymph node in patients with breast cancer using Tc-99m sulfur colloid and periareolar injection. Pritsivelis C; Garcia Mendonça CA; Pinheiro Pessoa MC; Coelho-Oliveira A; Gutfilen B; Barbosa Da Fonseca LM Q J Nucl Med Mol Imaging; 2007 Jun; 51(2):189-93. PubMed ID: 17420718 [TBL] [Abstract][Full Text] [Related]
15. Preoperative lymphoscintigraphy and internal mammary sentinel lymph node biopsy do not enhance the accuracy of lymphatic mapping for breast cancer. Lawson LL; Sandler M; Martin W; Beauchamp RD; Kelley MC Am Surg; 2004 Dec; 70(12):1050-5; discussion 1055-6. PubMed ID: 15663043 [TBL] [Abstract][Full Text] [Related]
16. Nonvisualization of axillary sentinel node during lymphoscintigraphy: is there a pathologic significance in breast cancer? Brenot-Rossi I; Houvenaeghel G; Jacquemier J; Bardou VJ; Martino M; Hassan-Sebbag N; Pasquier J J Nucl Med; 2003 Aug; 44(8):1232-7. PubMed ID: 12902412 [TBL] [Abstract][Full Text] [Related]
17. Comparison between one day and two days protocols for sentinel node mapping of breast cancer patients. Ali J; Alireza R; Mostafa M; Naser FM; Bahram M; Ramin S Hell J Nucl Med; 2011; 14(3):313-5. PubMed ID: 22087458 [TBL] [Abstract][Full Text] [Related]
18. Radio-guided sentinel lymph node biopsy using periareolar injection technique for patients with early breast cancer. Yen RF; Kuo WH; Lien HC; Chen TH; Jan IS; Wu YW; Wang MY; Chang KJ; Huang CS J Formos Med Assoc; 2007 Jan; 106(1):44-50. PubMed ID: 17282970 [TBL] [Abstract][Full Text] [Related]
19. Clinical significance of the lymphoscintigraphy in the evaluation of non-axillary sentinel lymph node localization in breast cancer. Gherghe M; Bordea C; Blidaru A Chirurgia (Bucur); 2015; 110(1):26-32. PubMed ID: 25800312 [TBL] [Abstract][Full Text] [Related]
20. Preoperative lymphoscintigraphy for breast cancer does not improve the ability to identify axillary sentinel lymph nodes. McMasters KM; Wong SL; Tuttle TM; Carlson DJ; Brown CM; Dirk Noyes R; Glaser RL; Vennekotter DJ; Turk PS; Tate PS; Sardi A; Edwards MJ Ann Surg; 2000 May; 231(5):724-31. PubMed ID: 10767794 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]