These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

282 related articles for article (PubMed ID: 15828785)

  • 1. Cytometry and velocimetry on a microfluidic chip using polyelectrolytic salt bridges.
    Chun H; Chung TD; Kim HC
    Anal Chem; 2005 Apr; 77(8):2490-5. PubMed ID: 15828785
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Red blood cell quantification microfluidic chip using polyelectrolytic gel electrodes.
    Kim KB; Chun H; Kim HC; Chung TD
    Electrophoresis; 2009 May; 30(9):1464-9. PubMed ID: 19340832
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sample concentration and impedance detection on a microfluidic polymer chip.
    Sabounchi P; Morales AM; Ponce P; Lee LP; Simmons BA; Davalos RV
    Biomed Microdevices; 2008 Oct; 10(5):661-70. PubMed ID: 18484178
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultrafast active mixer using polyelectrolytic ion extractor.
    Chun H; Kim HC; Chung TD
    Lab Chip; 2008 May; 8(5):764-71. PubMed ID: 18432347
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous low-voltage dc electroporation on a microfluidic chip with polyelectrolytic salt bridges.
    Kim SK; Kim JH; Kim KP; Chung TD
    Anal Chem; 2007 Oct; 79(20):7761-6. PubMed ID: 17874852
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A portable microfluidic flow cytometer based on simultaneous detection of impedance and fluorescence.
    Joo S; Kim KH; Kim HC; Chung TD
    Biosens Bioelectron; 2010 Feb; 25(6):1509-15. PubMed ID: 20004091
    [TBL] [Abstract][Full Text] [Related]  

  • 7. On-chip determination of spermatozoa concentration using electrical impedance measurements.
    Segerink LI; Sprenkels AJ; ter Braak PM; Vermes I; van den Berg A
    Lab Chip; 2010 Apr; 10(8):1018-24. PubMed ID: 20358109
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Single-layer planar on-chip flow cytometer using microfluidic drifting based three-dimensional (3D) hydrodynamic focusing.
    Mao X; Lin SC; Dong C; Huang TJ
    Lab Chip; 2009 Jun; 9(11):1583-9. PubMed ID: 19458866
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dual frequency dielectrophoresis with interdigitated sidewall electrodes for microfluidic flow-through separation of beads and cells.
    Wang L; Lu J; Marchenko SA; Monuki ES; Flanagan LA; Lee AP
    Electrophoresis; 2009 Mar; 30(5):782-91. PubMed ID: 19197906
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microfluidic system for dielectrophoretic separation based on a trapezoidal electrode array.
    Choi S; Park JK
    Lab Chip; 2005 Oct; 5(10):1161-7. PubMed ID: 16175274
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lateral displacement as a function of particle size using a piecewise curved planar interdigitated electrode array.
    Han KH; Han SI; Frazier AB
    Lab Chip; 2009 Oct; 9(20):2958-64. PubMed ID: 19789750
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry.
    Holmes D; Pettigrew D; Reccius CH; Gwyer JD; van Berkel C; Holloway J; Davies DE; Morgan H
    Lab Chip; 2009 Oct; 9(20):2881-9. PubMed ID: 19789739
    [TBL] [Abstract][Full Text] [Related]  

  • 13. On-chip micro-biosensor for the detection of human CD4(+) cells based on AC impedance and optical analysis.
    Mishra NN; Retterer S; Zieziulewicz TJ; Isaacson M; Szarowski D; Mousseau DE; Lawrence DA; Turner JN
    Biosens Bioelectron; 2005 Nov; 21(5):696-704. PubMed ID: 16242607
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microfluidic device for dielectrophoresis manipulation and electrodisruption of respiratory pathogen Bordetella pertussis.
    de la Rosa C; Tilley PA; Fox JD; Kaler KV
    IEEE Trans Biomed Eng; 2008 Oct; 55(10):2426-32. PubMed ID: 18838368
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Silicon-based microfilters for whole blood cell separation.
    Ji HM; Samper V; Chen Y; Heng CK; Lim TM; Yobas L
    Biomed Microdevices; 2008 Apr; 10(2):251-7. PubMed ID: 17914675
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Controlling two-dimensional movement of microparticles over an electrode array surface.
    Lin JT; Yeow JT; Wan W
    Biomed Microdevices; 2009 Feb; 11(1):193-200. PubMed ID: 18815885
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On-demand patterning of protein matrixes inside a microfluidic device.
    Kaji H; Hashimoto M; Nishizawa M
    Anal Chem; 2006 Aug; 78(15):5469-73. PubMed ID: 16878884
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optically induced flow cytometry for continuous microparticle counting and sorting.
    Lin YH; Lee GB
    Biosens Bioelectron; 2008 Dec; 24(4):572-8. PubMed ID: 18635347
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A disposable and cost efficient microfluidic device for the rapid chip-based electrical detection of DNA.
    Schüler T; Kretschmer R; Jessing S; Urban M; Fritzsche W; Möller R; Popp J
    Biosens Bioelectron; 2009 Sep; 25(1):15-21. PubMed ID: 19592230
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Titanium-based dielectrophoresis devices for microfluidic applications.
    Zhang YT; Bottausci F; Rao MP; Parker ER; Mezic I; Macdonald NC
    Biomed Microdevices; 2008 Aug; 10(4):509-17. PubMed ID: 18214682
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.