These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

318 related articles for article (PubMed ID: 15831326)

  • 21. [Ultrasonic tissue characterization of diseased myocardium by scanning acoustic microscopy].
    Saijo Y; Sasaki H; Naganuma T; Tanaka M
    J Cardiol; 1995 Mar; 25(3):127-32. PubMed ID: 7722873
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Estimation of ultrasound attenuation from broadband echo-signals using bandpass filtering.
    Kim H; Zagzebski JA; Varghese T
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 May; 55(5):1153-9. PubMed ID: 18519224
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Attenuation estimations using envelope echo data: analysis and simulations.
    Tu H; Zagzebski J; Chen Q
    Ultrasound Med Biol; 2006 Mar; 32(3):377-86. PubMed ID: 16530096
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Acoustic Properties of Breast Fat.
    Nasief HG; Rosado-Mendez IM; Zagzebski JA; Hall TJ
    J Ultrasound Med; 2015 Nov; 34(11):2007-16. PubMed ID: 26446820
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Potential relationships among myocardial stiffness, the measured level of myocardial backscatter ("image brightness"), and the magnitude of the systematic variation of backscatter (cyclic variation) over the heart cycle.
    Holland MR; Wallace KD; Miller JG
    J Am Soc Echocardiogr; 2004 Nov; 17(11):1131-7. PubMed ID: 15502786
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Hybrid spectral domain method for attenuation slope estimation.
    Kim H; Varghese T
    Ultrasound Med Biol; 2008 Nov; 34(11):1808-19. PubMed ID: 18621468
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Parametric (integrated backscatter and attenuation) images constructed using backscattered radio frequency signals (25-56 MHz) from human aortae in vitro.
    Bridal SL; Fornès P; Bruneval P; Berger G
    Ultrasound Med Biol; 1997; 23(2):215-29. PubMed ID: 9140180
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Microprocessor-base system for ultrasonic tissue characterization.
    Bhagat PK; Kadaba MP; Gupta VN; Wu V
    Med Instrum; 1980; 14(4):220-4. PubMed ID: 7412654
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of tissue anisotropy on the spectral characteristics of ultrasonic backscatter measured with a clinical imaging system.
    Holland MR; Lewis SH; Hall CS; Finch-Johnston AE; Handley SM; Wallace KD; D'sa AP; Prater DM; Perez JE; Miller JG
    Ultrason Imaging; 1998 Jul; 20(3):178-90. PubMed ID: 9921618
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Influence of attenuation on measurements of ultrasonic myocardial integrated backscatter during cardiac cycle (an in vitro study).
    van der Steen AF; Rijsterborgh H; Mastik F; Lancée CT; van Hoorn WM; Bom N
    Ultrasound Med Biol; 1991; 17(9):869-77. PubMed ID: 1805478
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Measurements of the anisotropy of ultrasonic velocity in freshly excised and formalin-fixed myocardial tissue.
    Baldwin SL; Yang M; Marutyan KR; Wallace KD; Holland MR; Miller JG
    J Acoust Soc Am; 2005 Jul; 118(1):505-13. PubMed ID: 16119369
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Ultrasonic characterization of human cancellous bone in vitro using three different apparent backscatter parameters in the frequency range 0.6-15.0 mhz.
    Hoffmeister BK; Johnson DP; Janeski JA; Keedy DA; Steinert BW; Viano AM; Kaste SC
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Jul; 55(7):1442-52. PubMed ID: 18986933
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Myocardial Fiber Mapping of Rat Hearts, Using Apparent Backscatter, with Histologic Validation.
    Milne ML; Schick BM; Alkhazal T; Chung CS
    Ultrasound Med Biol; 2019 Aug; 45(8):2075-2085. PubMed ID: 31155403
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Anisotropy of the slope of ultrasonic attenuation in formalin fixed human myocardium.
    Verdonk ED; Hoffmeister BK; Wickline SA; Miller JG
    J Acoust Soc Am; 1996 Jun; 99(6):3837-43. PubMed ID: 8655813
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Measurement of speed of sound dispersion in soft tissues using a double frequency continuous wave method.
    Levy Y; Agnon Y; Azhari H
    Ultrasound Med Biol; 2006 Jul; 32(7):1065-71. PubMed ID: 16829320
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Measurement of broadband temperature-dependent ultrasonic attenuation and dispersion using photoacoustics.
    Treeby BE; Cox BT; Zhang EZ; Patch SK; Beard PC
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Aug; 56(8):1666-76. PubMed ID: 19686982
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A 100-200 MHz ultrasound biomicroscope.
    Knspik DA; Starkoski B; Pavlin CJ; Foster FS
    IEEE Trans Ultrason Ferroelectr Freq Control; 2000; 47(6):1540-9. PubMed ID: 18238700
    [TBL] [Abstract][Full Text] [Related]  

  • 38. US backscatter and attenuation 30 to 50 MHz and MR T2 at 3 Tesla for differentiation of atherosclerotic artery constituents in vitro.
    Bridal SL; Toussaint JF; Raynaud JS; Fornes P; Leroy-Willig A; Berger G
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(6):1517-25. PubMed ID: 18249999
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Time-varying autoregressive spectral estimation for ultrasound attenuation in tissue characterization.
    Girault JM; Ossant F; Ouahabi A; Kouame D; Patat F
    IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(3):650-9. PubMed ID: 18244216
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Ultrasonic backscatter and attenuation (11-27 MHz) variation with collagen fiber distribution in ex vivo human dermis.
    Bridal SL; Fournier C; Coron A; Leguerney I; Laugier P
    Ultrason Imaging; 2006 Jan; 28(1):23-40. PubMed ID: 16924880
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.