211 related articles for article (PubMed ID: 15837408)
1. Detectability of liver metastases in malignant melanoma: prospective comparison of magnetic resonance imaging and positron emission tomography.
Ghanem N; Altehoefer C; Högerle S; Nitzsche E; Lohrmann C; Schäfer O; Kotter E; Langer M
Eur J Radiol; 2005 May; 54(2):264-70. PubMed ID: 15837408
[TBL] [Abstract][Full Text] [Related]
2. (18)F-fluorodeoxyglucose positron emission tomography/computed tomography and magnetic resonance imaging in patients with liver metastases from uveal melanoma: results from a pilot study.
Orcurto V; Denys A; Voelter V; Schalenbourg A; Schnyder P; Zografos L; Leyvraz S; Delaloye AB; Prior JO
Melanoma Res; 2012 Feb; 22(1):63-9. PubMed ID: 22027909
[TBL] [Abstract][Full Text] [Related]
3. Preoperative staging of liver metastases from uveal melanoma by magnetic resonance imaging (MRI) and fluorodeoxyglucose-positron emission tomography (FDG-PET).
Servois V; Mariani P; Malhaire C; Petras S; Piperno-Neumann S; Plancher C; Levy-Gabriel C; Lumbroso-le Rouic L; Desjardins L; Salmon RJ
Eur J Surg Oncol; 2010 Feb; 36(2):189-94. PubMed ID: 19775851
[TBL] [Abstract][Full Text] [Related]
4. "One-stop-shop" staging: should we prefer FDG-PET/CT or MRI for the detection of bone metastases?
Heusner T; Gölitz P; Hamami M; Eberhardt W; Esser S; Forsting M; Bockisch A; Antoch G
Eur J Radiol; 2011 Jun; 78(3):430-5. PubMed ID: 19945240
[TBL] [Abstract][Full Text] [Related]
5. Gadoxetate disodium-enhanced magnetic resonance imaging versus contrast-enhanced 18F-fluorodeoxyglucose positron emission tomography/computed tomography for the detection of colorectal liver metastases.
Seo HJ; Kim MJ; Lee JD; Chung WS; Kim YE
Invest Radiol; 2011 Sep; 46(9):548-55. PubMed ID: 21577131
[TBL] [Abstract][Full Text] [Related]
6. Contrast-enhanced FDG-PET/CT vs. SPIO-enhanced MRI vs. FDG-PET vs. CT in patients with liver metastases from colorectal cancer: a prospective study with intraoperative confirmation.
Rappeport ED; Loft A; Berthelsen AK; von der Recke P; Larsen PN; Mogensen AM; Wettergren A; Rasmussen A; Hillingsoe J; Kirkegaard P; Thomsen C
Acta Radiol; 2007 May; 48(4):369-78. PubMed ID: 17453514
[TBL] [Abstract][Full Text] [Related]
7. Liver lesion detection and characterization in patients with colorectal cancer: a comparison of low radiation dose non-enhanced PET/CT, contrast-enhanced PET/CT, and liver MRI.
Cantwell CP; Setty BN; Holalkere N; Sahani DV; Fischman AJ; Blake MA
J Comput Assist Tomogr; 2008; 32(5):738-44. PubMed ID: 18830103
[TBL] [Abstract][Full Text] [Related]
8. Detection of liver metastases from adenocarcinoma of the colon and pancreas: comparison of mangafodipir trisodium-enhanced liver MRI and whole-body FDG PET.
Sahani DV; Kalva SP; Fischman AJ; Kadavigere R; Blake M; Hahn PF; Saini S
AJR Am J Roentgenol; 2005 Jul; 185(1):239-46. PubMed ID: 15972430
[TBL] [Abstract][Full Text] [Related]
9. Diagnostic accuracy of dynamic gadoxetic-acid-enhanced MRI and PET/CT compared in patients with liver metastases from neuroendocrine neoplasms.
Armbruster M; Zech CJ; Sourbron S; Ceelen F; Auernhammer CJ; Rist C; Haug A; Singnurkar A; Reiser MF; Sommer WH
J Magn Reson Imaging; 2014 Aug; 40(2):457-66. PubMed ID: 24347148
[TBL] [Abstract][Full Text] [Related]
10. Simultaneous positron emission tomography/magnetic resonance imaging for whole-body staging in patients with recurrent gynecological malignancies of the pelvis: a comparison to whole-body magnetic resonance imaging alone.
Grueneisen J; Beiderwellen K; Heusch P; Gratz M; Schulze-Hagen A; Heubner M; Kinner S; Forsting M; Lauenstein T; Ruhlmann V; Umutlu L
Invest Radiol; 2014 Dec; 49(12):808-15. PubMed ID: 25010207
[TBL] [Abstract][Full Text] [Related]
11. Depiction and characterization of liver lesions in whole body [¹⁸F]-FDG PET/MRI.
Beiderwellen K; Gomez B; Buchbender C; Hartung V; Poeppel TD; Nensa F; Kuehl H; Bockisch A; Lauenstein TC
Eur J Radiol; 2013 Nov; 82(11):e669-75. PubMed ID: 24011443
[TBL] [Abstract][Full Text] [Related]
12. Detection of liver metastases in patients with adenocarcinomas of the gastrointestinal tract: comparison of (18)F-FDG PET/CT and MR imaging.
Maegerlein C; Fingerle AA; Souvatzoglou M; Rummeny EJ; Holzapfel K
Abdom Imaging; 2015 Jun; 40(5):1213-22. PubMed ID: 25348732
[TBL] [Abstract][Full Text] [Related]
13. A prospective diagnostic accuracy study of 18F-fluorodeoxyglucose positron emission tomography/computed tomography, multidetector row computed tomography, and magnetic resonance imaging in primary diagnosis and staging of pancreatic cancer.
Kauhanen SP; Komar G; Seppänen MP; Dean KI; Minn HR; Kajander SA; Rinta-Kiikka I; Alanen K; Borra RJ; Puolakkainen PA; Nuutila P; Ovaska JT
Ann Surg; 2009 Dec; 250(6):957-63. PubMed ID: 19687736
[TBL] [Abstract][Full Text] [Related]
14. Assessment of local control after laser-induced thermotherapy of liver metastases from colorectal cancer: contribution of FDG-PET in patients with clinical suspicion of progressive disease.
Denecke T; Steffen I; Hildebrandt B; Rühl R; Streitparth F; Lehmkuhl L; Langrehr J; Ricke J; Amthauer H; Hänninen EL
Acta Radiol; 2007 Oct; 48(8):821-30. PubMed ID: 17924212
[TBL] [Abstract][Full Text] [Related]
15. Initial M Staging of Rectal Cancer: FDG PET/MRI with a Hepatocyte-specific Contrast Agent versus Contrast-enhanced CT.
Yoon JH; Lee JM; Chang W; Kang HJ; Bandos A; Lim HJ; Kang SY; Kang KW; Ryoo SB; Jeong SY; Park KJ
Radiology; 2020 Feb; 294(2):310-319. PubMed ID: 31793850
[TBL] [Abstract][Full Text] [Related]
16. Diagnostic accuracy of diffusion-weighted magnetic resonance imaging versus positron emission tomography/computed tomography for early response assessment of liver metastases to Y90-radioembolization.
Barabasch A; Kraemer NA; Ciritsis A; Hansen NL; Lierfeld M; Heinzel A; Trautwein C; Neumann U; Kuhl CK
Invest Radiol; 2015 Jun; 50(6):409-15. PubMed ID: 25763526
[TBL] [Abstract][Full Text] [Related]
17. The added value of PET/Ce-CT/DW-MRI fusion in assessment of hepatic focal lesions: PET/Ce-CT/DW-MRI fusion in hepatic focal lesion.
Salem S; Houseni M; Zidan L; Kandil A
Nucl Med Biol; 2015 Jul; 42(7):637-42. PubMed ID: 25907467
[TBL] [Abstract][Full Text] [Related]
18. Optimizing positron emission tomography image acquisition protocols in integrated positron emission tomography/magnetic resonance imaging.
Hartung-Knemeyer V; Beiderwellen KJ; Buchbender C; Kuehl H; Lauenstein TC; Bockisch A; Poeppel TD
Invest Radiol; 2013 May; 48(5):290-4. PubMed ID: 23399811
[TBL] [Abstract][Full Text] [Related]
19. Comparison of MR and PET imaging for the evaluation of liver metastases.
Yang M; Martin DR; Karabulut N; Frick MP
J Magn Reson Imaging; 2003 Mar; 17(3):343-9. PubMed ID: 12594725
[TBL] [Abstract][Full Text] [Related]
20. 18 F-FDG PET/MR imaging in patients with suspected liver lesions: Value of liver-specific contrast agent Gadobenate dimeglumine.
Kirchner J; Sawicki LM; Deuschl C; Grüneisen J; Beiderwellen K; Lauenstein TC; Herrmann K; Forsting M; Heusch P; Umutlu L
PLoS One; 2017; 12(7):e0180349. PubMed ID: 28683109
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]