299 related articles for article (PubMed ID: 15839339)
1. Image reconstruction in peripheral and central regions-of-interest and data redundancy.
Pan X; Zou Y; Xia D
Med Phys; 2005 Mar; 32(3):673-84. PubMed ID: 15839339
[TBL] [Abstract][Full Text] [Related]
2. Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector.
Leng S; Zhuang T; Nett BE; Chen GH
Phys Med Biol; 2005 Apr; 50(8):1805-20. PubMed ID: 15815097
[TBL] [Abstract][Full Text] [Related]
3. Region of interest reconstruction from truncated data in circular cone-beam CT.
Yu L; Zou Y; Sidky EY; Pelizzari CA; Munro P; Pan X
IEEE Trans Med Imaging; 2006 Jul; 25(7):869-81. PubMed ID: 16827488
[TBL] [Abstract][Full Text] [Related]
4. Region-of-interest reconstruction of motion-contaminated data using a weighted backprojection filtration algorithm.
King M; Pan X; Yu L; Giger M
Med Phys; 2006 May; 33(5):1222-38. PubMed ID: 16752557
[TBL] [Abstract][Full Text] [Related]
5. A rebinned backprojection-filtration algorithm for image reconstruction in helical cone-beam CT.
Yu L; Xia D; Zou Y; Sidky EY; Bian J; Pan X
Phys Med Biol; 2007 Sep; 52(18):5497-508. PubMed ID: 17804878
[TBL] [Abstract][Full Text] [Related]
6. PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch.
Zou Y; Pan X; Xia D; Wang G
Med Phys; 2005 Aug; 32(8):2639-48. PubMed ID: 16193794
[TBL] [Abstract][Full Text] [Related]
7. Backprojection-filtration reconstruction without invoking a spatially varying weighting factor.
Xia D; Cho S; Pan X
Med Phys; 2010 Mar; 37(3):1201-9. PubMed ID: 20384257
[TBL] [Abstract][Full Text] [Related]
8. A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans.
Pan X; Xia D; Zou Y; Yu L
Phys Med Biol; 2004 Sep; 49(18):4349-69. PubMed ID: 15509070
[TBL] [Abstract][Full Text] [Related]
9. A local region of interest image reconstruction via filtered backprojection for fan-beam differential phase-contrast computed tomography.
Qi Z; Chen GH
Phys Med Biol; 2007 Sep; 52(18):N417-23. PubMed ID: 17804875
[TBL] [Abstract][Full Text] [Related]
10. A novel extension of the parallel-beam projection-slice theorem to divergent fan-beam and cone-beam projections.
Chen GH; Leng S; Mistretta CA
Med Phys; 2005 Mar; 32(3):654-65. PubMed ID: 15839337
[TBL] [Abstract][Full Text] [Related]
11. Cone-beam and fan-beam image reconstruction algorithms based on spherical and circular harmonics.
Zeng GL; Gullberg GT
Phys Med Biol; 2004 Jun; 49(11):2239-56. PubMed ID: 15248575
[TBL] [Abstract][Full Text] [Related]
12. Axial Cone-Beam Reconstruction by Weighted BPF/DBPF and Orthogonal Butterfly Filtering.
Tang S; Tang X
IEEE Trans Biomed Eng; 2016 Sep; 63(9):1895-1903. PubMed ID: 26660512
[TBL] [Abstract][Full Text] [Related]
13. Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data.
Zhuang T; Leng S; Nett BE; Chen GH
Phys Med Biol; 2004 Dec; 49(24):5489-503. PubMed ID: 15724538
[TBL] [Abstract][Full Text] [Related]
14. A BPF-type algorithm for CT with a curved PI detector.
Tang J; Zhang L; Chen Z; Xing Y; Cheng J
Phys Med Biol; 2006 Aug; 51(16):N287-93. PubMed ID: 16885611
[TBL] [Abstract][Full Text] [Related]
15. Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: preliminary phantom study.
Ning R; Tang X; Conover D; Yu R
Med Phys; 2003 Jul; 30(7):1694-705. PubMed ID: 12906186
[TBL] [Abstract][Full Text] [Related]
16. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.
Tang X; Hsieh J; Nilsen RA; Dutta S; Samsonov D; Hagiwara A
Phys Med Biol; 2006 Feb; 51(4):855-74. PubMed ID: 16467583
[TBL] [Abstract][Full Text] [Related]
17. Fourier-based forward and back-projectors in iterative fan-beam tomographic image reconstruction.
Zhang-O'Connor Y; Fessler JA
IEEE Trans Med Imaging; 2006 May; 25(5):582-9. PubMed ID: 16689262
[TBL] [Abstract][Full Text] [Related]
18. Tilted cone-beam reconstruction with row-wise fan-to-parallel rebinning.
Hsieh J; Tang X
Phys Med Biol; 2006 Oct; 51(20):5259-76. PubMed ID: 17019037
[TBL] [Abstract][Full Text] [Related]
19. A filtered backprojection algorithm for cone beam reconstruction using rotational filtering under helical source trajectory.
Tang X; Hsieh J
Med Phys; 2004 Nov; 31(11):2949-60. PubMed ID: 15587646
[TBL] [Abstract][Full Text] [Related]
20. Hilbert transform based FBP algorithm for fan-beam CT full and partial scans.
You J; Zeng GL
IEEE Trans Med Imaging; 2007 Feb; 26(2):190-9. PubMed ID: 17304733
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]