These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 15849441)

  • 1. Myocardial perfusion imaging using adenosine triphosphate stress multi-slice spiral computed tomography: alternative to stress myocardial perfusion scintigraphy.
    Kurata A; Mochizuki T; Koyama Y; Haraikawa T; Suzuki J; Shigematsu Y; Higaki J
    Circ J; 2005 May; 69(5):550-7. PubMed ID: 15849441
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transmural perfusion gradient in adenosine triphosphate stress myocardial perfusion computed tomography.
    Hosokawa K; Kurata A; Kido T; Shikata F; Imagawa H; Kawachi K; Ogimoto A; Higaki J; Kido T; Higashino H; Mochizuki T
    Circ J; 2011; 75(8):1905-12. PubMed ID: 21697608
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Detection of coronary artery disease by adenosine triphosphate stress echocardiography: comparison with adenosine triphosphate stress thallium myocardial scintigraphy and coronary angiography].
    Harada M; Okura K; Nishizawa S; Inoue T; Sakai H; Lee T; Sugiyama Y; Suzuki M; Hirai H; Yamaguchi T
    J Cardiol; 1998 Sep; 32(3):163-71. PubMed ID: 9783237
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Combined analysis of multislice computed tomography coronary angiography and stress-rest myocardial perfusion imaging in detecting patients with significant proximal coronary artery stenosis.
    Fujitaka K; Nakamura S; Sugiura T; Hatada K; Tsuka Y; Umemura S; Fujikawa Y; Baden M; Iwasaka T
    Nucl Med Commun; 2009 Oct; 30(10):789-96. PubMed ID: 19641477
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection of myocardial ischemia using 64-slice MDCT.
    Nagao M; Matsuoka H; Kawakami H; Higashino H; Mochizuki T; Ohshita A; Kohno T; Shigemi S
    Circ J; 2009 May; 73(5):905-11. PubMed ID: 19325193
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Adenosine triphosphate stress echocardiography in the detection of myocardial ischemia.
    Fukai T; Koyanagi S; Tashiro H; Ichiki T; Tsutsui H; Matsumoto T; Takeshita A
    Am J Card Imaging; 1995 Oct; 9(4):237-44. PubMed ID: 8680139
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Application value between dynamic electrocardiogram and MSCT myocardial perfusion imaging in the diagnosis of myocardial ischemia in coronary heart disease.
    Chen P; Wu T; Peng Q; Fan N; Shi Y; Wang H; Chen L; Guo H
    Ann Palliat Med; 2021 Oct; 10(10):10720-10725. PubMed ID: 34763433
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thallium-201 myocardial tomography with intravenous infusion of adenosine triphosphate in diagnosis of coronary artery disease.
    Miyagawa M; Kumano S; Sekiya M; Watanabe K; Akutzu H; Imachi T; Tanada S; Hamamoto K
    J Am Coll Cardiol; 1995 Nov; 26(5):1196-201. PubMed ID: 7594032
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Predictive value of multislice computed tomography variables of atherosclerosis for ischemia on stress-rest single-photon emission computed tomography.
    van Velzen JE; Schuijf JD; van Werkhoven JM; Herzog BA; Pazhenkottil AP; Boersma E; de Graaf FR; Scholte AJ; Kroft LJ; de Roos A; Stokkel MP; Jukema JW; Kaufmann PA; van der Wall EE; Bax JJ
    Circ Cardiovasc Imaging; 2010 Nov; 3(6):718-26. PubMed ID: 20660145
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dipyridamole stress and rest myocardial perfusion by 64-detector row computed tomography in patients with suspected coronary artery disease.
    Cury RC; Magalhães TA; Borges AC; Shiozaki AA; Lemos PA; Júnior JS; Meneghetti JC; Cury RC; Rochitte CE
    Am J Cardiol; 2010 Aug; 106(3):310-5. PubMed ID: 20643238
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Diagnostic value of myocardial perfusion imaging and multislice spiral computed tomography for coronary artery disease].
    Tang K; Shi RF; Zhao XB
    Zhonghua Xin Xue Guan Bing Za Zhi; 2008 Sep; 36(9):816-9. PubMed ID: 19102865
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Relationship between noninvasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging.
    Schuijf JD; Wijns W; Jukema JW; Atsma DE; de Roos A; Lamb HJ; Stokkel MP; Dibbets-Schneider P; Decramer I; De Bondt P; van der Wall EE; Vanhoenacker PK; Bax JJ
    J Am Coll Cardiol; 2006 Dec; 48(12):2508-14. PubMed ID: 17174190
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Myocardial ischemia detection with single-phase CT perfusion in symptomatic patients using high-pitch helical image acquisition technique.
    Bischoff B; Deseive S; Rampp M; Todica A; Wermke M; Martinoff S; Massberg S; Reiser MF; Becker HC; Hausleiter J
    Int J Cardiovasc Imaging; 2017 Apr; 33(4):569-576. PubMed ID: 27848163
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Myocardial perfusion imaging to assess ischemia using multislice computed tomography.
    van Werkhoven JM; Schuijf JD; Bax JJ
    Expert Rev Cardiovasc Ther; 2009 Jan; 7(1):49-56. PubMed ID: 19105766
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Multislice spiral computed tomography of the heart in dilated cardiomyopathy: possibilities in the verification of myocarditis (in comparison with myocardial biopsy) and in the evaluation of prognosis].
    Alieva IN; Blagova OV; Gagarina NV; Nedostup AV; Kogan EA; Sedov VP; Kadochnikova VV; Donnikov AE; Zaidenov VA; Kupriyanova AG; Ternovoy SK
    Ter Arkh; 2017; 89(12):15-27. PubMed ID: 29411756
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Real-time perfusion adenosine stress echocardiography versus myocardial perfusion adenosine scintigraphy for the detection of myocardial ischaemia in patients with stable coronary artery disease.
    Gudmundsson P; Winter R; Dencker M; Kitlinski M; Thorsson O; Ljunggren L; Willenheimer R
    Clin Physiol Funct Imaging; 2006 Jan; 26(1):32-8. PubMed ID: 16398668
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A randomized controlled trial of multi-slice coronary computed tomography for evaluation of acute chest pain.
    Goldstein JA; Gallagher MJ; O'Neill WW; Ross MA; O'Neil BJ; Raff GL
    J Am Coll Cardiol; 2007 Feb; 49(8):863-71. PubMed ID: 17320744
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multicentre multi-device hybrid imaging study of coronary artery disease: results from the EValuation of INtegrated Cardiac Imaging for the Detection and Characterization of Ischaemic Heart Disease (EVINCI) hybrid imaging population.
    Liga R; Vontobel J; Rovai D; Marinelli M; Caselli C; Pietila M; Teresinska A; Aguadé-Bruix S; Pizzi MN; Todiere G; Gimelli A; Chiappino D; Marraccini P; Schroeder S; Drosch T; Poddighe R; Casolo G; Anagnostopoulos C; Pugliese F; Rouzet F; Le Guludec D; Cappelli F; Valente S; Gensini GF; Zawaideh C; Capitanio S; Sambuceti G; Marsico F; Filardi PP; Fernández-Golfín C; Rincón LM; Graner FP; de Graaf MA; Stehli J; Reyes E; Nkomo S; Mäki M; Lorenzoni V; Turchetti G; Carpeggiani C; Puzzuoli S; Mangione M; Marcheschi P; Giannessi D; Nekolla S; Lombardi M; Sicari R; Scholte AJ; Zamorano JL; Underwood SR; Knuuti J; Kaufmann PA; Neglia D; Gaemperli O;
    Eur Heart J Cardiovasc Imaging; 2016 Sep; 17(9):951-60. PubMed ID: 26992419
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The study of myocardial perfusion by cardiac volumetric computed tomography, combined with adenosine triphosphate test, in a patient with painless myocardial ischemia and atherosclerosis of the coronary arteries].
    Soboleva GN; Gaman SA; Ternovoy SK; Karpov YA; Minasyan AA; Shariya MA; Shitov VN; Mironov VM
    Ter Arkh; 2020 May; 92(4):76-79. PubMed ID: 32598702
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of myocardial viability in reperfused acute myocardial infarction using 16-slice computed tomography in comparison to magnetic resonance imaging.
    Mahnken AH; Koos R; Katoh M; Wildberger JE; Spuentrup E; Buecker A; Günther RW; Kühl HP
    J Am Coll Cardiol; 2005 Jun; 45(12):2042-7. PubMed ID: 15963407
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.