127 related articles for article (PubMed ID: 15854965)
1. First clinical experience with the HEARTSTRING, a device for proximal anastomoses in coronary surgery.
Vicol C; Oberhoffer M; Nollert G; Eifert S; Boekstegers P; Wintersperger B; Reichart B
Ann Thorac Surg; 2005 May; 79(5):1732-7; discussion 1737. PubMed ID: 15854965
[TBL] [Abstract][Full Text] [Related]
2. [New proximal anastomotic system in coronary artery bypass grafting].
Sasaki Y; Shibata T; Hirai H; Hosono M; Fukui T; Fujii H; Arimoto H; Motoki M; Bito Y; Takahashi Y; Suehiro S
Kyobu Geka; 2006 Jul; 59(7):538-42. PubMed ID: 16856527
[TBL] [Abstract][Full Text] [Related]
3. Initial experience with the Heartstring proximal anastomotic system.
Medalion B; Meirson D; Hauptman E; Sasson L; Schachner A
J Thorac Cardiovasc Surg; 2004 Aug; 128(2):273-7. PubMed ID: 15282465
[TBL] [Abstract][Full Text] [Related]
4. Twelve-month patency with the PAS-port proximal connector device: a single center prospective randomized trial.
Kempfert J; Opfermann UT; Richter M; Bossert T; Mohr FW; Gummert JF
Ann Thorac Surg; 2008 May; 85(5):1579-84. PubMed ID: 18442542
[TBL] [Abstract][Full Text] [Related]
5. Intermediate-term patency of saphenous vein graft with a clampless hand-sewn proximal anastomosis device after off-pump coronary bypass grafting.
Shimokawa T; Manabe S; Sawada T; Matsuyama S; Fukui T; Takanashi S
Ann Thorac Surg; 2009 May; 87(5):1416-20. PubMed ID: 19379877
[TBL] [Abstract][Full Text] [Related]
6. Avoidance of aortic side-clamping for proximal bypass anastomoses: better short-term outcome?
Wilhelm MJ; Syburra T; Furrer L; Frielingsdorf J; Odavic D; Graves K; Genoni M
Heart Surg Forum; 2011 Dec; 14(6):E360-5. PubMed ID: 22167762
[TBL] [Abstract][Full Text] [Related]
7. Clinical experience with the CorLink device for proximal anastomosis of the saphenous vein to the aorta: a clinical, prospective, and randomized study.
Riess FC; Helmold H; Hilfer I; Bader R; Stripling J; Loewer C; Wesner F; Bleese N
Heart Surg Forum; 2002; 5(4):345-53. PubMed ID: 12538116
[TBL] [Abstract][Full Text] [Related]
8. Guidant Heartstring: initial experience in OPCAB surgery.
Weber A; Reuthebuch O; Turina M
Heart Surg Forum; 2005; 8(1):E4-8. PubMed ID: 15769713
[TBL] [Abstract][Full Text] [Related]
9. Impact of proximal anastomosis procedures on stroke in off-pump coronary artery bypass grafting.
Manabe S; Fukui T; Miyajima K; Watanabe Y; Matsuyama S; Shimokawa T; Takanashi S
J Card Surg; 2009; 24(6):644-9. PubMed ID: 20078710
[TBL] [Abstract][Full Text] [Related]
10. Initial experience with the enclose proximal aortic anastomosis device during off-pump coronary artery bypass: an alternative to aortic side clamping.
Boova RS; Trace C; Leshnower BG
Heart Surg Forum; 2006; 9(2):E607-11. PubMed ID: 16543162
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of the enclose proximal anastomosis device in coronary artery bypass grafting.
Aranki SF; Shekar PS; Ehsan A; Byrne-Taft M; Couper GS
Ann Thorac Surg; 2005 Sep; 80(3):1091-5. PubMed ID: 16122495
[TBL] [Abstract][Full Text] [Related]
12. Early clinical experience with a new sutureless anastomotic device for proximal anastomosis of the saphenous vein to the aorta.
Calafiore AM; Bar-El Y; Vitolla G; Di Giammarco G; Teodori G; Iacò AL; D'Alessandro S; Di Mauro M
J Thorac Cardiovasc Surg; 2001 May; 121(5):854-8. PubMed ID: 11326228
[TBL] [Abstract][Full Text] [Related]
13. Vettath's anastomotic obturator: a simple proximal anastomotic device.
Vettath MP
Heart Surg Forum; 2003; 6(5):366-8. PubMed ID: 14721811
[TBL] [Abstract][Full Text] [Related]
14. Gaseous and solid cerebral microembolization during proximal aortic anastomoses in off-pump coronary surgery: the effect of an aortic side-biting clamp and two clampless devices.
Guerrieri Wolf L; Abu-Omar Y; Choudhary BP; Pigott D; Taggart DP
J Thorac Cardiovasc Surg; 2007 Feb; 133(2):485-93. PubMed ID: 17258587
[TBL] [Abstract][Full Text] [Related]
15. Use of skeletonized radial artery graft with the PAS-Port proximal anastomotic device.
Yamaguchi S; Watanabe G; Tomita S; Ohtake H; Nagamine H; Iino K
Ann Thorac Surg; 2009 Jun; 87(6):1910-3. PubMed ID: 19463618
[TBL] [Abstract][Full Text] [Related]
16. Results with the Heartstring anastomotic device in patients with diseased ascending aorta.
Biancari F; Mosorin M; Lahtinen J; Heikkinen J; Rasinaho E; Anttila V; Lepojärvi M; Juvonen T
Scand Cardiovasc J; 2006 Aug; 40(4):238-9. PubMed ID: 16914416
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial).
Puskas JD; Halkos ME; Balkhy H; Caskey M; Connolly M; Crouch J; Diegeler A; Gummert J; Harringer W; Subramanian V; Sutter F; Matschke K;
J Thorac Cardiovasc Surg; 2009 Jul; 138(1):125-32. PubMed ID: 19577069
[TBL] [Abstract][Full Text] [Related]
18. Meta-analysis on the use of the Heartstring anastomotic device to prevent stroke in patients undergoing off-pump coronary artery bypass grafting.
Biancari F; Yli-Pyky S
Eur J Cardiothorac Surg; 2011 Nov; 40(5):1236-40. PubMed ID: 21420873
[TBL] [Abstract][Full Text] [Related]
19. "Beyond beating heart surgery": heartstring device protects against perioperative neurological events.
Sakopoulos AG; Jacobson JG; Wilson DR; Huse WM
Innovations (Phila); 2010 Mar; 5(2):118-21. PubMed ID: 22437359
[TBL] [Abstract][Full Text] [Related]
20. Initial experience with sutureless proximal anastomoses performed with a mechanical connector leading to clampless off-pump coronary artery bypass surgery.
Katariya K; Yassin S; Tehrani HY; Lombardi P; Masroor S; Salerno TA
Ann Thorac Surg; 2004 Feb; 77(2):563-7; discussion 567-8. PubMed ID: 14759438
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]