BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 15860105)

  • 1. Arthrodesis of the equine proximal interphalangeal joint: a mechanical comparison of 2 parallel 5.5 mm cortical screws and 3 parallel 5.5 mm cortical screws.
    Read EK; Chandler D; Wilson DG
    Vet Surg; 2005; 34(2):142-7. PubMed ID: 15860105
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Arthrodesis of the proximal interphalangeal joint in the horse: a cyclic biomechanical comparison of two and three parallel cortical screws inserted in lag fashion.
    Carmalt JL; Delaney L; Wilson DG
    Vet Surg; 2010 Jan; 39(1):91-4. PubMed ID: 20210951
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: two parallel transarticular headless tapered variable pitch screws versus two parallel transarticular AO cortical bone screws inserted in lag fashion.
    Gudehus T; Sod GA; Riggs LM; Mitchell CF; Martin GS
    Vet Surg; 2011 Apr; 40(3):261-5. PubMed ID: 21361995
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion.
    Sod GA; Mitchell CF; Hubert JD; Martin GS; Gill MS
    Vet Surg; 2007 Dec; 36(8):792-9. PubMed ID: 18067621
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of two parallel headless, tapered, variable-pitched, titanium compression screws and two parallel 5.5 mm stainless-steel cortical screws.
    Wolker RR; Carmalt JL; Wilson DG
    Vet Surg; 2009 Oct; 38(7):861-7. PubMed ID: 19781029
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion.
    Sod GA; Riggs LM; Mitchell CF; Hubert JD; Martin GS
    Vet Surg; 2010 Jan; 39(1):83-90. PubMed ID: 20210950
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 3-hole 4.5 mm locking compression plate and 3-hole 4.5 mm narrow dynamic compression plate, with two transarticular 5.5 mm cortex screws.
    Zoppa AL; Santoni B; Puttlitz CM; Cochran K; Hendrickson DA
    Vet Surg; 2011 Feb; 40(2):253-9. PubMed ID: 21244444
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of two surgical procedures for arthrodesis of the proximal interphalangeal joint in horses.
    Genetzky RM; Schneider EJ; Butler HC; Guffy MM
    J Am Vet Med Assoc; 1981 Sep; 179(5):464-8. PubMed ID: 7309610
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of three 4.5-mm and two 5.5-mm cortical screws.
    Watt BC; Edwards RB; Markel MD; McCabe R; Wilson DG
    Vet Surg; 2001; 30(3):287-94. PubMed ID: 11340561
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A mechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial locking compression plate and two abaxial transarticular cortical screws versus an axial dynamic compression plate and two abaxial transarticular cortical screws.
    Sod GA; Riggs LM; Mitchell CF; Martin GS
    Vet Surg; 2011 Jul; 40(5):571-8. PubMed ID: 21521241
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Proximal interphalangeal arthrodesis in 22 horses.
    Schaer TP; Bramlage LR; Embertson RM; Hance S
    Equine Vet J; 2001 Jul; 33(4):360-5. PubMed ID: 11469768
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Proximal interphalangeal joint arthrodesis in 34 horses using two parallel 5.5-mm cortical bone screws.
    MacLellan KN; Crawford WH; MacDonald DG
    Vet Surg; 2001; 30(5):454-9. PubMed ID: 11555821
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of a collateral ligament sparing surgical approach on mechanical properties of equine proximal interphalangeal joint arthrodesis constructs.
    Bras JJ; Lillich JD; Beard WL; Anderson DE; Armbrust LJ; Frink E; Lease K
    Vet Surg; 2011 Jan; 40(1):73-81. PubMed ID: 21077916
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A technique for laser-facilitated equine pastern arthrodesis using parallel screws inserted in lag fashion.
    Watts AE; Fortier LA; Nixon AJ; Ducharme NG
    Vet Surg; 2010 Feb; 39(2):244-53. PubMed ID: 20210975
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of two 7-hole 3.5-mm broad and two 5-hole 4.5-mm narrow dynamic compression plates.
    Watt BC; Edwards RB; Markel MD; McCabe R; Wilson DG
    Vet Surg; 2002; 31(1):85-93. PubMed ID: 11778172
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro biomechanical comparison of a 4.5 mm narrow locking compression plate construct versus a 4.5 mm limited contact dynamic compression plate construct for arthrodesis of the equine proximal interphalangeal joint.
    Ahern BJ; Showalter BL; Elliott DM; Richardson DW; Getman LM
    Vet Surg; 2013 Apr; 42(3):335-9. PubMed ID: 23445267
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Arthrodesis of the proximal interphalangeal joint in the horse: a surgical treatment for high ringbone.
    Schneider JE; Carnine BL; Guffy MM
    J Am Vet Med Assoc; 1978 Nov; 173(10):1364-9. PubMed ID: 365842
    [No Abstract]   [Full Text] [Related]  

  • 18. Proximal interphalangeal joint arthrodesis using a combination plate-screw technique in 53 horses (1994-2003).
    Knox PM; Watkins JP
    Equine Vet J; 2006 Nov; 38(6):538-42. PubMed ID: 17124844
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of ethyl alcohol for use in a minimally invasive technique for equine proximal interphalangeal joint arthrodesis.
    Wolker RR; Wilson DG; Allen AL; Carmalt JL
    Vet Surg; 2011 Apr; 40(3):291-8. PubMed ID: 21244446
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro biomechanical comparison of a 5-hole 4.5 mm locking compression plate and 5-hole 4.5 mm dynamic compression plate for equine proximal interphalangeal joint arthrodesis.
    Seo JP; Yamaga T; Tsuzuki N; Yamada K; Haneda S; Furuoka H; Sasaki N
    Vet Surg; 2014 Jul; 43(5):606-11. PubMed ID: 24512440
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.