These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

61 related articles for article (PubMed ID: 1586541)

  • 1. Reflotron measurement of blood cholesterol.
    Majeed FA
    Br J Gen Pract; 1992 Jan; 42(354):40. PubMed ID: 1586541
    [No Abstract]   [Full Text] [Related]  

  • 2. Measurement of capillary cholesterol as an aid to the management of hypertensive patients with hyperlipidaemia--an assessment of the Reflotron.
    Curzio JL; Farish E; Howie C; Kennedy SS; Barnes J; Reid JJ
    J Hum Hypertens; 1992 Jun; 6(3):185-8. PubMed ID: 1629886
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Measurement of blood cholesterol, decentralized, using a Reflotron, or centralized in a laboratory. A comparison].
    Christensen TE; Agner E; Jensen SE; Jacobsen K; Mahnfeldt MS; Baastrup A
    Ugeskr Laeger; 1990 Nov; 152(45):3346-8. PubMed ID: 2238225
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of the ratio HDL-cholesterol/total cholesterol on the Reflotron vs. conventional wet chemistry methods.
    Herruer MH; Kluitenberg WE; Zuijderhoudt FM
    Eur J Clin Chem Clin Biochem; 1992 Mar; 30(3):153-5. PubMed ID: 1599979
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Measurement of cholesterol in capillary blood using the Reflotron system. Results from approximately 1,000 comparisons with reference measurements of cholesterol in venous serum].
    Gerdes LU; Bak AM; Faergeman O
    Ugeskr Laeger; 1990 Jun; 152(24):1739-43. PubMed ID: 2360292
    [TBL] [Abstract][Full Text] [Related]  

  • 6. How accurately does the Reflotron dry-chemistry system measure plasma total cholesterol levels when used a community-screening device.
    Phillips S; Wyndham L; Shaw J; Walker SF
    Med J Aust; 1988 Aug; 149(3):122-5. PubMed ID: 3398798
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Precision of a dry-chemistry method of lipid screening.
    Bowden RG; Kingery PM; Long L
    Public Health; 2006 Jun; 120(6):572-6. PubMed ID: 16730036
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A review of the analytic performance of the Reflotron System for cholesterol testing.
    Statland BE
    Clin Ther; 1990; 12(3):281-6. PubMed ID: 2199060
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A multicentre study of the new Reflotron system for the measurement of urea, glucose, triacylglycerols, cholesterol, gamma-glutamyltransferase and haemoglobin.
    Price CP; Koller PU
    J Clin Chem Clin Biochem; 1988 Apr; 26(4):233-50. PubMed ID: 2900287
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reflotron performance in a community screening program: results of the Massachusetts Model Systems for Blood Cholesterol Screening Project.
    Havas S; Bishop R; Koumjian L; Reisman J; Wozenski S
    Am J Prev Med; 1991; 7(6):397-405. PubMed ID: 1790049
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Reflotron Total Cholesterol assay in heparinized venous and capillary blood.
    Boerma GJ; Liem TL; Jacobs-de Haas JA; de Jong-van Staveren FA; Verbree W; Eman I
    J Clin Chem Clin Biochem; 1990 Apr; 28(4):255-8. PubMed ID: 2358795
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reflotron cholesterol measurement in general practice: accuracy and detection of errors.
    Ball MJ; Robertson IK; Woods M
    Ann Clin Biochem; 1994 Nov; 31 ( Pt 6)():556-60. PubMed ID: 7880074
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of cholesterol, triglycerides, and HDL using compact analysis systems.
    Warnick GR
    Clin Lab Med; 1989 Mar; 9(1):73-88. PubMed ID: 2647378
    [TBL] [Abstract][Full Text] [Related]  

  • 14. How accurate is the Reflotron cholesterol analyzer? 2. Reflotron screenings considered a success.
    Feil JM
    Am J Public Health; 1993 Mar; 83(3):428-9. PubMed ID: 8438987
    [No Abstract]   [Full Text] [Related]  

  • 15. The 'Reflotron' for cholesterol and triglyceride measurements in the surgery.
    Chambers JP; Fitzgerald RJ; Tormey WP
    Ir Med J; 1988 Nov; 81(1):38-9. PubMed ID: 3220700
    [No Abstract]   [Full Text] [Related]  

  • 16. Measurement of blood cholesterol with the Reflotron analyzer evaluated.
    Råstam L; Admire JB; Frantz ID; Hellerstedt W; Hunninghake DM; Kuba K; Luepker RV
    Clin Chem; 1988 Feb; 34(2):426. PubMed ID: 3342525
    [No Abstract]   [Full Text] [Related]  

  • 17. A multi-centre evaluation of the measurement of high density lipoprotein cholesterol by the Reflotron assay.
    Bijster P
    Eur J Clin Chem Clin Biochem; 1993 Mar; 31(3):173-8. PubMed ID: 8490064
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of serum cholesterol on the Reflotron (BBR) dry chemistry analyser. Assessment of accuracy.
    Sanguini LC; Ceriotti F; Franzini C; Grossi L; Bonini PA
    Ann Biol Clin (Paris); 1988; 46(5):319-21. PubMed ID: 3421519
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The method of dry chemical analysis of trout blood with Reflotron].
    Mohr A; Schütze G
    Tierarztl Prax; 1988; 16(3):321-4. PubMed ID: 2903584
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of intensified training of operators on the determination of cholesterol on Reflotron in the doctor's office.
    Rohac M; Thalhammer J; Gabl F; Bayer PM
    J Clin Chem Clin Biochem; 1988 Jan; 26(1):39-41. PubMed ID: 3373150
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.