These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

265 related articles for article (PubMed ID: 15876655)

  • 21. A novel electrode array for diameter-dependent control of axonal excitability: a simulation study.
    Lertmanorat Z; Durand DM
    IEEE Trans Biomed Eng; 2004 Jul; 51(7):1242-50. PubMed ID: 15248540
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A cortical (V1) neurophysiological recording model for assessing the efficacy of retinal visual prostheses.
    Elfar SD; Cottaris NP; Iezzi R; Abrams GW
    J Neurosci Methods; 2009 Jun; 180(2):195-207. PubMed ID: 19464512
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Development of an extraocular retinal prosthesis: evaluation of stimulation parameters in the cat.
    Chowdhury V; Morley JW; Coroneo MT
    J Clin Neurosci; 2008 Aug; 15(8):900-6. PubMed ID: 18586497
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A method for generating precise temporal patterns of retinal spiking using prosthetic stimulation.
    Fried SI; Hsueh HA; Werblin FS
    J Neurophysiol; 2006 Feb; 95(2):970-8. PubMed ID: 16236780
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Performance optimization of current focusing and virtual electrode strategies in retinal implants.
    Khalili Moghaddam G; Lovell NH; Wilke RG; Suaning GJ; Dokos S
    Comput Methods Programs Biomed; 2014 Nov; 117(2):334-42. PubMed ID: 25023532
    [TBL] [Abstract][Full Text] [Related]  

  • 26. In vivo evaluation of an episcleral multielectrode array for stimulation of the retina with reduced retinal ganglion cell mass.
    Siu TL; Morley JW
    J Clin Neurosci; 2008 May; 15(5):552-8. PubMed ID: 18342512
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Action potentials in retinal ganglion cells are initiated at the site of maximal curvature of the extracellular potential.
    Eickenscheidt M; Zeck G
    J Neural Eng; 2014 Jun; 11(3):036006. PubMed ID: 24762943
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Current density distributions, field distributions and impedance analysis of segmented deep brain stimulation electrodes.
    Wei XF; Grill WM
    J Neural Eng; 2005 Dec; 2(4):139-47. PubMed ID: 16317238
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Integrate-and-fire model for electrically stimulated nerve cell.
    Robert ME
    IEEE Trans Biomed Eng; 2006 Apr; 53(4):756-8. PubMed ID: 16602584
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Different pulse shapes to obtain small fiber selective activation by anodal blocking--a simulation study.
    Vucković A; Rijkhoff NJ; Struijk JJ
    IEEE Trans Biomed Eng; 2004 May; 51(5):698-706. PubMed ID: 15132495
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Laboratory investigation of microelectronics-based stimulators for large-scale suprachoroidal transretinal stimulation (STS).
    Ohta J; Tokuda T; Kagawa K; Sugitani S; Taniyama M; Uehara A; Terasawa Y; Nakauchi K; Fujikado T; Tano Y
    J Neural Eng; 2007 Mar; 4(1):S85-91. PubMed ID: 17325420
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Monopolar vs. bipolar subretinal stimulation-an in vitro study.
    Gerhardt M; Groeger G; Maccarthy N
    J Neurosci Methods; 2011 Jul; 199(1):26-34. PubMed ID: 21557968
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Responses of rabbit retinal ganglion cells to subretinal electrical stimulation using a silicon-based microphotodiode array.
    Yang YT; Lin PK; Wan C; Yang WC; Lin LJ; Wu CY; Chiao CC
    Invest Ophthalmol Vis Sci; 2011 Dec; 52(13):9353-61. PubMed ID: 22058338
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Tunable retina encoders for retina implants: why and how.
    Eckmiller R; Neumann D; Baruth O
    J Neural Eng; 2005 Mar; 2(1):S91-S104. PubMed ID: 15876659
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Responses of ganglion cells to repetitive electrical stimulation of the retina.
    Jensen RJ; Rizzo JF
    J Neural Eng; 2007 Mar; 4(1):S1-6. PubMed ID: 17325407
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effects of different three-dimensional electrodes on epiretinal electrical stimulation by modeling analysis.
    Cao X; Sui X; Lyu Q; Li L; Chai X
    J Neuroeng Rehabil; 2015 Aug; 12():73. PubMed ID: 26311232
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Extracellular stimulation window explained by a geometry-based model of the neuron-electrode contact.
    Buitenweg JR; Rutten WL; Marani E
    IEEE Trans Biomed Eng; 2002 Dec; 49(12 Pt 2):1591-9. PubMed ID: 12549741
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Electric field stimulation of bipolar cells in a degenerated retina--a theoretical study.
    Gerhardt M; Alderman J; Stett A
    IEEE Trans Neural Syst Rehabil Eng; 2010 Feb; 18(1):1-10. PubMed ID: 20071281
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Energy-optimal electrical excitation of nerve fibers.
    Jezernik S; Morari M
    IEEE Trans Biomed Eng; 2005 Apr; 52(4):740-3. PubMed ID: 15825876
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A preparation for studying electrical stimulation of the retina in vivo in rat.
    Baig-Silva MS; Hathcock CD; Hetling JR
    J Neural Eng; 2005 Mar; 2(1):S29-38. PubMed ID: 15876652
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.