1. A biomechanical evaluation of the Gamma nail. Rosenblum SF; Zuckerman JD; Kummer FJ; Tam BS J Bone Joint Surg Br; 1992 May; 74(3):352-7. PubMed ID: 1587875 [TBL] [Abstract][Full Text] [Related]
2. Biomechanical analysis of the Gamma nail and sliding hip screw. Mahomed N; Harrington I; Kellam J; Maistrelli G; Hearn T; Vroemen J Clin Orthop Relat Res; 1994 Jul; (304):280-8. PubMed ID: 8020229 [TBL] [Abstract][Full Text] [Related]
3. The effect of implant overlap on the mechanical properties of the femur. Harris T; Ruth JT; Szivek J; Haywood B J Trauma; 2003 May; 54(5):930-5. PubMed ID: 12777906 [TBL] [Abstract][Full Text] [Related]
4. A biomechanical evaluation of the long stem intramedullary hip screw. Bostrom MP; Lyden JP; Ernberg JJ; Missri AA; Berberian WS J Orthop Trauma; 1995 Feb; 9(1):45-52. PubMed ID: 7714653 [TBL] [Abstract][Full Text] [Related]
5. The effect of two different trochanteric nail lag-screw designs on fixation stability of four-part intertrochanteric fractures: a clinical and biomechanical study. Takemoto RC; Lekic N; Schwarzkopf R; Kummer FJ; Egol KA J Orthop Sci; 2014 Jan; 19(1):112-9. PubMed ID: 24248549 [TBL] [Abstract][Full Text] [Related]
6. A biomechanical analysis of the sliding hip screw: the question of plate angle. Meislin RJ; Zuckerman JD; Kummer FJ; Frankel VH J Orthop Trauma; 1990; 4(2):130-6. PubMed ID: 2358926 [TBL] [Abstract][Full Text] [Related]
8. The effect of locked distal screws in retrograde nailing of osteoporotic distal femur fractures: a laboratory study using cadaver femurs. Tejwani NC; Park S; Iesaka K; Kummer F J Orthop Trauma; 2005 Jul; 19(6):380-3. PubMed ID: 16003196 [TBL] [Abstract][Full Text] [Related]
9. [Progress on distal interlocking screw of cephalomedullary nail for intertrochanteric fractures]. Li Q; Zhang S Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Sep; 28(9):1177-80. PubMed ID: 25509788 [TBL] [Abstract][Full Text] [Related]
11. Long Segment Blocking Screws Increase the Stability of Retrograde Nail Fixation in Geriatric Supracondylar Femur Fractures: Eliminating the "Bell-Clapper Effect". Auston D; Donohue D; Stoops K; Cox J; Diaz M; Santoni B; Mir H J Orthop Trauma; 2018 Nov; 32(11):559-564. PubMed ID: 30086037 [TBL] [Abstract][Full Text] [Related]
12. Comparison of compression hip screw and gamma nail for treatment of peritrochanteric fractures. Bess RJ; Jolly SA J South Orthop Assoc; 1997; 6(3):173-9. PubMed ID: 9322196 [TBL] [Abstract][Full Text] [Related]
13. Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. Madsen JE; Naess L; Aune AK; Alho A; Ekeland A; Strømsøe K J Orthop Trauma; 1998 May; 12(4):241-8. PubMed ID: 9619458 [TBL] [Abstract][Full Text] [Related]
14. The effect of fracture pattern stability on implant loading in OTA type 31-A2 proximal femur fractures. Marmor M; Liddle K; Pekmezci M; Buckley J; Matityahu A J Orthop Trauma; 2013 Dec; 27(12):683-9. PubMed ID: 23412511 [TBL] [Abstract][Full Text] [Related]
15. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Parker MJ; Handoll HH Cochrane Database Syst Rev; 2008 Jul; (3):CD000093. PubMed ID: 18646058 [TBL] [Abstract][Full Text] [Related]
16. Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: a cadaver study. Bong MR; Patel V; Iesaka K; Egol KA; Kummer FJ; Koval KJ J Trauma; 2004 Apr; 56(4):791-4. PubMed ID: 15187744 [TBL] [Abstract][Full Text] [Related]
17. A biomechanical comparison of static versus dynamic lag screw modes for cephalomedullary nails used to fix unstable peritrochanteric fractures. Kuzyk PR; Shah S; Zdero R; Olsen M; Waddell JP; Schemitsch EH J Trauma Acute Care Surg; 2012 Feb; 72(2):E65-70. PubMed ID: 22439235 [TBL] [Abstract][Full Text] [Related]
18. Biomechanical evaluation of interlocking lag screw design in intramedullary nailing of unstable pertrochanteric fractures. Hoffmann S; Paetzold R; Stephan D; Püschel K; Buehren V; Augat P J Orthop Trauma; 2013 Sep; 27(9):483-90. PubMed ID: 23860133 [TBL] [Abstract][Full Text] [Related]
19. The medial femoral wall can play a more important role in unstable intertrochanteric fractures compared with lateral femoral wall: a biomechanical study. Nie B; Chen X; Li J; Wu D; Liu Q J Orthop Surg Res; 2017 Dec; 12(1):197. PubMed ID: 29282138 [TBL] [Abstract][Full Text] [Related]