These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Metabolic profiling studies on the toxicological effects of realgar in rats by (1)H NMR spectroscopy. Wei L; Liao P; Wu H; Li X; Pei F; Li W; Wu Y Toxicol Appl Pharmacol; 2009 Feb; 234(3):314-25. PubMed ID: 19073202 [TBL] [Abstract][Full Text] [Related]
6. Singular spectrum analysis for an automated solvent artifact removal and baseline correction of 1D NMR spectra. De Sanctis S; Malloni WM; Kremer W; Tomé AM; Lang EW; Neidig KP; Kalbitzer HR J Magn Reson; 2011 Jun; 210(2):177-83. PubMed ID: 21459640 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of algorithms for automated phase correction of NMR spectra. de Brouwer H J Magn Reson; 2009 Dec; 201(2):230-8. PubMed ID: 19836281 [TBL] [Abstract][Full Text] [Related]
8. Slice-selective FID acquisition, localized by outer volume suppression (FIDLOVS) for (1)H-MRSI of the human brain at 7 T with minimal signal loss. Henning A; Fuchs A; Murdoch JB; Boesiger P NMR Biomed; 2009 Aug; 22(7):683-96. PubMed ID: 19259944 [TBL] [Abstract][Full Text] [Related]
9. Water suppression without signal loss in HR-MAS 1H NMR of cells and tissues. Chen JH; Sambol EB; Kennealey PT; O'Connor RB; DeCarolis PL; Cory DG; Singer S J Magn Reson; 2004 Nov; 171(1):143-50. PubMed ID: 15504693 [TBL] [Abstract][Full Text] [Related]
10. Metabonomics investigation of human urine after ingestion of green tea with gas chromatography/mass spectrometry, liquid chromatography/mass spectrometry and (1)H NMR spectroscopy. Law WS; Huang PY; Ong ES; Ong CN; Li SF; Pasikanti KK; Chan EC Rapid Commun Mass Spectrom; 2008 Aug; 22(16):2436-46. PubMed ID: 18634125 [TBL] [Abstract][Full Text] [Related]
12. Robust algorithms for automated chemical shift calibration of 1D 1H NMR spectra of blood serum. Pearce JT; Athersuch TJ; Ebbels TM; Lindon JC; Nicholson JK; Keun HC Anal Chem; 2008 Sep; 80(18):7158-62. PubMed ID: 18702533 [TBL] [Abstract][Full Text] [Related]
13. Reference deconvolution, phase correction, and line listing of NMR spectra by the 1D filter diagonalization method. Hu H; Van QN; Mandelshtam VA; Shaka AJ J Magn Reson; 1998 Sep; 134(1):76-87. PubMed ID: 9740734 [TBL] [Abstract][Full Text] [Related]
14. Metabonomic profiling of renal cell carcinoma: high-resolution proton nuclear magnetic resonance spectroscopy of human serum with multivariate data analysis. Gao H; Dong B; Liu X; Xuan H; Huang Y; Lin D Anal Chim Acta; 2008 Aug; 624(2):269-77. PubMed ID: 18706333 [TBL] [Abstract][Full Text] [Related]
15. Optimization of human plasma 1H NMR spectroscopic data processing for high-throughput metabolic phenotyping studies and detection of insulin resistance related to type 2 diabetes. Maher AD; Crockford D; Toft H; Malmodin D; Faber JH; McCarthy MI; Barrett A; Allen M; Walker M; Holmes E; Lindon JC; Nicholson JK Anal Chem; 2008 Oct; 80(19):7354-62. PubMed ID: 18759460 [TBL] [Abstract][Full Text] [Related]
16. High-resolution, high-sensitivity NMR of nanolitre anisotropic samples by coil spinning. Sakellariou D; Le Goff G; Jacquinot JF Nature; 2007 Jun; 447(7145):694-7. PubMed ID: 17554303 [TBL] [Abstract][Full Text] [Related]
17. Localized proton spectroscopy without water suppression: removal of gradient induced frequency modulations by modulus signal selection. Serrai H; Clayton DB; Senhadji L; Zuo C; Lenkinski RE J Magn Reson; 2002 Jan; 154(1):53-9. PubMed ID: 11820826 [TBL] [Abstract][Full Text] [Related]
18. Automatic alignment of individual peaks in large high-resolution spectral data sets. Stoyanova R; Nicholls AW; Nicholson JK; Lindon JC; Brown TR J Magn Reson; 2004 Oct; 170(2):329-35. PubMed ID: 15388097 [TBL] [Abstract][Full Text] [Related]
19. Metabolic profiling, metabolomic and metabonomic procedures for NMR spectroscopy of urine, plasma, serum and tissue extracts. Beckonert O; Keun HC; Ebbels TM; Bundy J; Holmes E; Lindon JC; Nicholson JK Nat Protoc; 2007; 2(11):2692-703. PubMed ID: 18007604 [TBL] [Abstract][Full Text] [Related]
20. Automatic correction for phase shifts, frequency shifts, and lineshape distortions across a series of single resonance lines in large spectral data sets. Witjes H; Melssen WJ; in 't Zandt HJ; van der Graaf M; Heerschap A; Buydens LM J Magn Reson; 2000 May; 144(1):35-44. PubMed ID: 10783271 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]