166 related articles for article (PubMed ID: 15890603)
1. A dosimetric study of Leipzig applicators.
Pérez-Calatayud J; Granero D; Ballester F; Puchades V; Casal E; Soriano A; Crispín V
Int J Radiat Oncol Biol Phys; 2005 Jun; 62(2):579-84. PubMed ID: 15890603
[TBL] [Abstract][Full Text] [Related]
2. Monte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192 HDR source.
Granero D; Pérez-Calatayud J; Ballester F
Radiother Oncol; 2005 Jul; 76(1):79-85. PubMed ID: 16019091
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.
Fulkerson RK; Micka JA; DeWerd LA
Med Phys; 2014 Feb; 41(2):022103. PubMed ID: 24506635
[TBL] [Abstract][Full Text] [Related]
4. Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate 192Ir sources.
Fulkerson RK; Micka JA; DeWerd LA
Med Phys; 2014 Feb; 41(2):022104. PubMed ID: 24506636
[TBL] [Abstract][Full Text] [Related]
5. The effect of finite patient dimensions and tissue inhomogeneities on dosimetry planning of 192Ir HDR breast brachytherapy: a Monte Carlo dose verification study.
Pantelis E; Papagiannis P; Karaiskos P; Angelopoulos A; Anagnostopoulos G; Baltas D; Zamboglou N; Sakelliou L
Int J Radiat Oncol Biol Phys; 2005 Apr; 61(5):1596-602. PubMed ID: 15817368
[TBL] [Abstract][Full Text] [Related]
6. Monte Carlo dosimetric study of the BEBIG Co-60 HDR source.
Ballester F; Granero D; Pérez-Calatayud J; Casal E; Agramunt S; Cases R
Phys Med Biol; 2005 Nov; 50(21):N309-16. PubMed ID: 16237230
[TBL] [Abstract][Full Text] [Related]
7. (144)Ce as a potential candidate for interstitial and intravascular brachytherapy.
Zilio VO; Joneja OP; Popowski Y; Bochud FO; Chawla R
Int J Radiat Oncol Biol Phys; 2005 Jun; 62(2):585-94. PubMed ID: 15890604
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo calculations of the dose distribution around a commercial gynecologic tandem applicator.
Gifford KA; Mourtada F; Cho SH; Lawyer A; Horton JL
Radiother Oncol; 2005 Nov; 77(2):210-5. PubMed ID: 16216363
[TBL] [Abstract][Full Text] [Related]
9. Dosimetric characterization of radioactive sources employed in prostate cancer therapy.
Zilio VO; Joneja OP; Popowski Y; Chawla R
Brachytherapy; 2004; 3(4):201-14. PubMed ID: 15607152
[TBL] [Abstract][Full Text] [Related]
10. Monte Carlo dosimetry of the microselectron HDR 192Ir brachytherapy source using MCNP4A.
Wallace S; Wong T; Fernando W
Australas Phys Eng Sci Med; 1998 Mar; 21(1):11-7. PubMed ID: 9633148
[TBL] [Abstract][Full Text] [Related]
11. Dosimetric characteristics of the Leipzig surface applicators used in the high dose rate brachy radiotherapy.
Niu H; Hsi WC; Chu JC; Kirk MC; Kouwenhoven E
Med Phys; 2004 Dec; 31(12):3372-7. PubMed ID: 15651620
[TBL] [Abstract][Full Text] [Related]
12. Dosimetric characteristics, air-kerma strength calibration and verification of Monte Carlo simulation for a new Ytterbium-169 brachytherapy source.
Perera H; Williamson JF; Li Z; Mishra V; Meigooni AS
Int J Radiat Oncol Biol Phys; 1994 Mar; 28(4):953-70. PubMed ID: 8138449
[TBL] [Abstract][Full Text] [Related]
13. Determination of dosimetric characteristics of OptiSeed(TM) a plastic brachytherapy (103)Pd source.
Wang Z; Hertel NE
Appl Radiat Isot; 2005 Sep; 63(3):311-21. PubMed ID: 15964196
[TBL] [Abstract][Full Text] [Related]
14. Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapy.
Valicenti RK; Kirov AS; Meigooni AS; Mishra V; Das RK; Williamson JF
Med Phys; 1995 Jun; 22(6):821-9. PubMed ID: 7565373
[TBL] [Abstract][Full Text] [Related]
15. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.
DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF
Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525
[TBL] [Abstract][Full Text] [Related]
16. Determination of the dose characteristics in the near area of a new type of 192Ir-HDR afterloading source with a pinpoint ionization chamber.
Gromoll C; Karg A
Phys Med Biol; 2002 Mar; 47(6):875-87. PubMed ID: 11936175
[TBL] [Abstract][Full Text] [Related]
17. Design and dosimetric characteristics of a high dose rate remotely afterloaded endocavitary applicator system.
Meigooni AS; Zhu Y; Williamson JF; Myerson RJ; Teague S; Löffler E; Nussbaum GH; Klein EE; Kodner IJ
Int J Radiat Oncol Biol Phys; 1996 Mar; 34(5):1153-63. PubMed ID: 8600101
[TBL] [Abstract][Full Text] [Related]
18. Experimental and Monte Carlo dosimetry of the Henschke applicator for high dose-rate 192Ir remote afterloading.
Watanabe Y; Roy J; Harrington PJ; Anderson LL
Med Phys; 1998 May; 25(5):736-45. PubMed ID: 9608485
[TBL] [Abstract][Full Text] [Related]
19. Measurement of dosimetric parameters for the Alpha-Omega high-dose-rate Iridium-192 source.
Muller-Runkel R
Med Dosim; 2005; 30(3):139-42. PubMed ID: 16112463
[TBL] [Abstract][Full Text] [Related]
20. Effects of off-centering on dose uniformity along and around blood vessels undergoing catheter-based intravascular brachytherapy.
Nath R; Yue N
Cardiovasc Radiat Med; 2004; 5(2):88-96. PubMed ID: 15464946
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]