These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 15897084)

  • 1. A finite element based algorithm for determining interfacial tension (gamma) from pendant drop profiles.
    Dingle NM; Tjiptowidjojo K; Basaran OA; Harris MT
    J Colloid Interface Sci; 2005 Jun; 286(2):647-60. PubMed ID: 15897084
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A robust algorithm for the simultaneous parameter estimation of interfacial tension and contact angle from sessile drop profiles.
    Dingle NM; Harris MT
    J Colloid Interface Sci; 2005 Jun; 286(2):670-80. PubMed ID: 15897086
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A non-gradient based algorithm for the determination of surface tension from a pendant drop: application to low Bond number drop shapes.
    Alvarez NJ; Walker LM; Anna SL
    J Colloid Interface Sci; 2009 May; 333(2):557-62. PubMed ID: 19261289
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Axisymmetric Drop Shape Analysis: Computational Methods for the Measurement of Interfacial Properties from the Shape and Dimensions of Pendant and Sessile Drops.
    Río OI; Neumann AW
    J Colloid Interface Sci; 1997 Dec; 196(2):136-147. PubMed ID: 9792739
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimisation of calculation methods for determination of surface tensions by drop profile analysis tensiometry.
    Zholob SA; Makievski AV; Miller R; Fainerman VB
    Adv Colloid Interface Sci; 2007 Oct; 134-135():322-9. PubMed ID: 17559784
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of surface tension and contact angle from the shapes of axisymmetric fluid interfaces without use of apex coordinates.
    Cabezas MG; Bateni A; Montanero JM; Neumann AW
    Langmuir; 2006 Nov; 22(24):10053-60. PubMed ID: 17106999
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of Interfacial Tension from the Profile of a Pendant Drop Using Computer-Aided Image Processing.
    Song B; Springer J
    J Colloid Interface Sci; 1996 Dec; 184(1):64-76. PubMed ID: 8954640
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accurate surface tension measurement of glass melts by the pendant drop method.
    Chang YY; Wu MY; Hung YL; Lin SY
    Rev Sci Instrum; 2011 May; 82(5):055107. PubMed ID: 21639538
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical models for the evaluation of the contact angle from axisymmetric drop profiles: a statistical comparison.
    Bortolotti M; Brugnara M; Della Volpe C; Siboni S
    J Colloid Interface Sci; 2009 Aug; 336(1):285-97. PubMed ID: 19398110
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of line tension on the shape of liquid menisci near stripwise heterogeneous walls.
    Hoorfar M; Amirfazli A; Gaydos JA; Neumann AW
    Adv Colloid Interface Sci; 2005 Jun; 114-115():103-18. PubMed ID: 15936285
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Experimental and numerical investigation of the equilibrium geometry of liquid lenses.
    Burton JC; Huisman FM; Alison P; Rogerson D; Taborek P
    Langmuir; 2010 Oct; 26(19):15316-24. PubMed ID: 20809604
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Interfacial tension of solid materials against dense carbon dioxide.
    Sutjiadi-Sia Y; Jaeger P; Eggers R
    J Colloid Interface Sci; 2008 Apr; 320(1):268-74. PubMed ID: 18255090
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dynamics of Drop Formation in an Electric Field.
    Notz PK; Basaran OA
    J Colloid Interface Sci; 1999 May; 213(1):218-237. PubMed ID: 10191025
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Elliptic solution to the Young-Laplace differential equation.
    Hernández-Baltazar E; Gracia-Fadrique J
    J Colloid Interface Sci; 2005 Jul; 287(1):213-6. PubMed ID: 15914169
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of a constant surface pressure penetration langmuir balance based on axisymmetric drop shape analysis.
    Wege HA; Holgado-Terriza JA; Cabrerizo-Vílchez MA
    J Colloid Interface Sci; 2002 May; 249(2):263-73. PubMed ID: 16290596
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microscopic treatment of a barrel drop on fibers and nanofibers.
    Berim GO; Ruckenstein E
    J Colloid Interface Sci; 2005 Jun; 286(2):681-95. PubMed ID: 15897087
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous measurement of contact angle and surface tension using axisymmetric drop-shape analysis-no apex (ADSA-NA).
    Kalantarian A; David R; Chen J; Neumann AW
    Langmuir; 2011 Apr; 27(7):3485-95. PubMed ID: 21355566
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of Interfacial Tension from the Profile of a Pendant Drop Using Computer-Aided Image Processing.
    Song B; Springer J
    J Colloid Interface Sci; 1996 Dec; 184(1):77-91. PubMed ID: 8954641
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of surface and interfacial tension using pendant drop tensiometry.
    Berry JD; Neeson MJ; Dagastine RR; Chan DY; Tabor RF
    J Colloid Interface Sci; 2015 Sep; 454():226-37. PubMed ID: 26037272
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simulations of gravity-induced trapping of a deformable drop in a three-dimensional constriction.
    Ratcliffe T; Zinchenko AZ; Davis RH
    J Colloid Interface Sci; 2012 Oct; 383(1):167-76. PubMed ID: 22795042
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.