BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

194 related articles for article (PubMed ID: 15906427)

  • 1. Real-time three-dimensional fetal echocardiography using matrix probe.
    Acar P; Dulac Y; Taktak A; Abadir S
    Prenat Diagn; 2005 May; 25(5):370-5. PubMed ID: 15906427
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Live 3D echocardiography with the pediatric matrix probe.
    Acar P; Abadir S; Paranon S; Latcu G; Grosjean J; Dulac Y
    Echocardiography; 2007 Aug; 24(7):750-5. PubMed ID: 17651105
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Pathological diagnosis of conotruncal defects by transthoracic three-dimensional echocardiography].
    Chen GZ; Sun K; Huang GY; Chen SB; Zhang YQ
    Zhonghua Er Ke Za Zhi; 2005 Sep; 43(9):681-4. PubMed ID: 16191302
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Four-dimensional volume-rendered imaging of the fetal ventricular outflow tracts and great arteries using inversion mode for detection of congenital heart disease.
    Hata T; Tanaka H; Noguchi J; Dai SY; Yamaguchi M; Yanagihara T
    J Obstet Gynaecol Res; 2010 Jun; 36(3):513-8. PubMed ID: 20598030
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-dimensional HDlive rendering images of the fetal heart.
    Hata T; Mashima M; Ito M; Uketa E; Mori N; Ishimura M
    Ultrasound Med Biol; 2013 Aug; 39(8):1513-7. PubMed ID: 23743102
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous real-time imaging of four-chamber and left ventricular outflow tract views using xPlane imaging capability of a matrix array probe.
    Yuan Y; Leung KY; Ouyang YS; Yang F; Tang MH; Chau AK; Dai Q
    Ultrasound Obstet Gynecol; 2011 Mar; 37(3):302-9. PubMed ID: 21077157
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Novel application of four-dimensional sonography with B-flow imaging and spatiotemporal image correlation in the assessment of fetal congenital heart defects.
    Hongmei W; Ying Z; Ailu C; Wei S
    Echocardiography; 2012 May; 29(5):614-9. PubMed ID: 22404098
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The 'spin' technique: a new method for examination of the fetal outflow tracts using three-dimensional ultrasound.
    DeVore GR; Polanco B; Sklansky MS; Platt LD
    Ultrasound Obstet Gynecol; 2004 Jul; 24(1):72-82. PubMed ID: 15229920
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three- and four-dimensional freehand fetal echocardiography: a feasibility study using a hand-held Doppler probe for cardiac gating.
    Herberg U; Goldberg H; Breuer J
    Ultrasound Obstet Gynecol; 2005 Apr; 25(4):362-71. PubMed ID: 15761914
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-dimensional (3D) echocardiographic analysis of congenital heart disease in the fetus: comparison with cross-sectional (2D) fetal echocardiography.
    Meyer-Wittkopf M; Cooper S; Vaughan J; Sholler G
    Ultrasound Obstet Gynecol; 2001 Jun; 17(6):485-92. PubMed ID: 11422968
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-dimensional (3D) and 4D color Doppler fetal echocardiography using spatio-temporal image correlation (STIC).
    Chaoui R; Hoffmann J; Heling KS
    Ultrasound Obstet Gynecol; 2004 Jun; 23(6):535-45. PubMed ID: 15170792
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fetal heart ventricular mass obtained by STIC acquisition combined with inversion mode and VOCAL.
    Messing B; Cohen SM; Valsky DV; Shen O; Rosenak D; Lipschuetz M; Yagel S
    Ultrasound Obstet Gynecol; 2011 Aug; 38(2):191-7. PubMed ID: 21370304
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real-time three-dimensional foetal echocardiography using a new transabdominal xMATRIX array transducer.
    Acar P; Battle L; Dulac Y; Peyre M; Dubourdieu H; Hascoet S; Groussolles M; Vayssière C
    Arch Cardiovasc Dis; 2014 Jan; 107(1):4-9. PubMed ID: 24364911
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of real-time three-dimensional echocardiography and spatiotemporal image correlation in assessment of fetal interventricular septum.
    Xiong Y; Liu T; Wu Y; Xu JF; Ting YH; Yeung Leung T; Lau TK
    J Matern Fetal Neonatal Med; 2012 Nov; 25(11):2333-8. PubMed ID: 22642553
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fetal cardiac ventricle volumetry in the second half of gestation assessed by 4D ultrasound using STIC combined with inversion mode.
    Messing B; Cohen SM; Valsky DV; Rosenak D; Hochner-Celnikier D; Savchev S; Yagel S
    Ultrasound Obstet Gynecol; 2007 Aug; 30(2):142-51. PubMed ID: 17566143
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Four-dimensional color Doppler reconstruction of the fetal heart with glass-body rendering mode.
    Hata T; Kanenishi K; Mori N; Yazon AO; Hanaoka U; Tanaka H
    Am J Cardiol; 2014 Nov; 114(10):1603-6. PubMed ID: 25242366
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Four-dimensional sonography with B-flow imaging and spatiotemporal image correlation for visualization of the fetal heart.
    Hata T; Dai SY; Inubashiri E; Kanenishi K; Tanaka H; Yanagihara T; Araki S
    J Clin Ultrasound; 2008 May; 36(4):204-7. PubMed ID: 18335509
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Echocardiography in the fetus--a systematic comparative analysis of standard cardiac views with 2D, 3D reconstructive and 3D real-time echocardiography.
    Herberg U; Steinweg B; Berg C; Breuer J
    Ultraschall Med; 2011 Jun; 32(3):293-301. PubMed ID: 20425686
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Second-generation real-time three-dimensional echocardiography. Finally on its way into clinical cardiology?
    von Bardeleben RS; Kühl HP; Mohr-Kahaly S; Franke A
    Z Kardiol; 2004; 93 Suppl 4():IV56-64. PubMed ID: 15085367
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spatio-temporal image correlation (STIC): a new tool for the prenatal screening of congenital heart defects.
    Viñals F; Poblete P; Giuliano A
    Ultrasound Obstet Gynecol; 2003 Oct; 22(4):388-94. PubMed ID: 14528475
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.