These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 15911678)

  • 1. The biomechanical effect of radial shortening on the radiocapitellar articulation.
    Diab M; Poston JM; Huber P; Tencer AF
    J Bone Joint Surg Br; 2005 Jun; 87(6):879-83. PubMed ID: 15911678
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of radial head implant length on radiocapitellar articular properties and load transfer within the forearm.
    Lanting BA; Ferreira LM; Johnson JA; King GJ; Athwal GS
    J Orthop Trauma; 2014 Jun; 28(6):348-53. PubMed ID: 24088774
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Axial load transmission through the elbow during forearm rotation.
    Hwang JT; Kim Y; Bachman DR; Shields MN; Berglund LJ; Fitzsimmons AT; Fitzsimmons JS; O'Driscoll SW
    J Shoulder Elbow Surg; 2018 Mar; 27(3):530-537. PubMed ID: 29290603
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow.
    Hackl M; Wegmann K; Kahmann SL; Heinze N; Staat M; Neiss WF; Scaal M; Müller LP
    Knee Surg Sports Traumatol Arthrosc; 2017 Jul; 25(7):2280-2288. PubMed ID: 28238092
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effects of distal radius fracture malalignment on forearm rotation: a cadaveric study.
    Bronstein AJ; Trumble TE; Tencer AF
    J Hand Surg Am; 1997 Mar; 22(2):258-62. PubMed ID: 9195423
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical characteristics of osteochondral defects of the humeral capitellum.
    Mihata T; Quigley R; Robicheaux G; McGarry MH; Neo M; Lee TQ
    Am J Sports Med; 2013 Aug; 41(8):1909-14. PubMed ID: 23749342
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Joint contact areas after radial head arthroplasty: a comparative study of 3 prostheses.
    Moungondo FGP; Andrzejewski A; van Riet RRP; Feipel V; Rooze M; Schuind FA
    J Shoulder Elbow Surg; 2019 Aug; 28(8):1546-1553. PubMed ID: 31029518
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radiocapitellar joint contacts after bipolar radial head arthroplasty.
    Moungondo F; El Kazzi W; van Riet R; Feipel V; Rooze M; Schuind F
    J Shoulder Elbow Surg; 2010 Mar; 19(2):230-5. PubMed ID: 20036580
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A new arthroscopic-assisted drilling method through the radius in a distal-to-proximal direction for osteochondritis dissecans of the elbow.
    Arai Y; Hara K; Fujiwara H; Minami G; Nakagawa S; Kubo T
    Arthroscopy; 2008 Feb; 24(2):237.e1-4. PubMed ID: 18237711
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo three-dimensional elbow biomechanics during forearm rotation.
    Omori S; Miyake J; Oka K; Tanaka H; Yoshikawa H; Murase T
    J Shoulder Elbow Surg; 2016 Jan; 25(1):112-9. PubMed ID: 26422527
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of prosthetic radial head geometry on the distribution and magnitude of radiocapitellar joint contact pressures.
    Bachman DR; Thaveepunsan S; Park S; Fitzsimmons JS; An KN; O'Driscoll SW
    J Hand Surg Am; 2015 Feb; 40(2):281-8. PubMed ID: 25542439
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The contact area of the radiocapitellar joint under pronation and supination with axial load using a 3-dimensional computed tomography: an in vivo study.
    Bian H; Kim H; Kholinne E; Sun Y; Kwak JM; Tan J
    J Shoulder Elbow Surg; 2021 Jun; 30(6):1238-1244. PubMed ID: 32950672
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of stem fit on the radiocapitellar contact mechanics of a metallic axisymmetric radial head hemiarthroplasty: is loose fit better than rigidly fixed?
    Szmit J; King GJW; Johnson JA; Langohr GDG
    J Shoulder Elbow Surg; 2019 Dec; 28(12):2394-2399. PubMed ID: 31371158
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Defining a safe zone of dissection during the extensor digitorum communis splitting approach to the proximal radius and forearm: an anatomic study.
    Schimizzi A; MacLennan A; Meier KM; Chia B; Catalano LW; Glickel SZ
    J Hand Surg Am; 2009 Sep; 34(7):1252-5. PubMed ID: 19700073
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of axial forearm instability on force transmission across the elbow.
    Hwang JT; Kim Y; Shields MN; Bachman DR; Berglund LJ; Fitzsimmons AT; Fitzsimmons JS; O'Driscoll SW
    J Shoulder Elbow Surg; 2019 Jan; 28(1):170-177. PubMed ID: 30337267
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A biomechanical analysis of articular cartilage of the human elbow and a potential relationship to osteochondritis dissecans.
    Schenck RC; Athanasiou KA; Constantinides G; Gomez E
    Clin Orthop Relat Res; 1994 Feb; (299):305-12. PubMed ID: 8119034
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of the orientation of the radial head on the kinematics of the ulnohumeral joint and force transmission through the radiocapitellar joint.
    van Riet RP; Van Glabbeek F; Baumfeld JA; Neale PG; Morrey BF; O'Driscoll SW; An KN
    Clin Biomech (Bristol, Avon); 2006 Jul; 21(6):554-9. PubMed ID: 16530305
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Contact analysis of the native radiocapitellar joint compared with axisymmetric and nonaxisymmetric radial head hemiarthroplasty.
    Langohr GD; Willing R; Medley JB; King GJ; Johnson JA
    J Shoulder Elbow Surg; 2015 May; 24(5):787-95. PubMed ID: 25725964
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radial Head Lag: A Possible Biomechanical Mechanism for Osteochondritis Dissecans of the Capitellum in Baseball Pitchers.
    Rotman D; Kwak JM; Rojas Lievano J; Hooke A; Camp CL; Fitzsimmons JS; O'Driscoll SW
    Am J Sports Med; 2021 Oct; 49(12):3226-3233. PubMed ID: 34523371
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of the annular ligament on kinematics of the radial head.
    Galik K; Baratz ME; Butler AL; Dougherty J; Cohen MS; Miller MC
    J Hand Surg Am; 2007 Oct; 32(8):1218-24. PubMed ID: 17923306
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.