BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 1591865)

  • 1. Serum analysis for potassium ions using a fibre optic sensor.
    Pereiro García R; Alava Moreno F; Díaz García ME; Sanz-Medel A; Narayanaswamy R
    Clin Chim Acta; 1992 Apr; 207(1-2):31-40. PubMed ID: 1591865
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fibre-optical sensor based on fluorescent indicator for monitoring physiological pH values.
    Zhang S; Tanaka S; Wickramasinghe YA; Rolfe P
    Med Biol Eng Comput; 1995 Mar; 33(2):152-6. PubMed ID: 7643652
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fiber-optic ammonia sensor for measuring synaptic glutamate and extracellular ammonia.
    Kar S; Arnold MA
    Anal Chem; 1992 Oct; 64(20):2438-43. PubMed ID: 1361308
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fibre optic sensor for the detection of potassium using fluorescence energy transfer.
    Roe JN; Szoka FC; Verkman AS
    Analyst; 1990 Apr; 115(4):353-8. PubMed ID: 2363517
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hydrophilic sensor membrane based on cation-selective protic chromoionophore.
    Krause C; Werner T; Huber C; Wolfbeis OS
    Fresenius J Anal Chem; 2000 Jul; 367(5):426-8. PubMed ID: 11227470
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fluorescent fiber-optic calcium sensor for physiological measurements.
    Shortreed M; Kopelman R; Kuhn M; Hoyland B
    Anal Chem; 1996 Apr; 68(8):1414-8. PubMed ID: 8651501
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fibre-optic oxygen sensor based on phosphorescence quenching.
    Papkovskii DB; Yaropolov AI; Savitskii AP; Olah J; Rumyantseva VD; Mironov AF; Troyanovskii IV; Sadovskii NA
    Biomed Sci; 1991; 2(5):536-9. PubMed ID: 1840843
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A microchip sensor for calcium determination.
    Caglar P; Tuncel SA; Malcik N; Landers JP; Ferrance JP
    Anal Bioanal Chem; 2006 Nov; 386(5):1303-12. PubMed ID: 17019572
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of an optical fibre reflectance sensor for p-aminophenol detection based on immobilised bis-8-hydroxyquinoline.
    Filik H; Hayvali M; Kiliç E; Apak R; Aksu D; Yanaz Z; Cengel T
    Talanta; 2008 Oct; 77(1):103-9. PubMed ID: 18804606
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Studies of the development of optical fiber sensors for biochemical analysis.
    Takai N; Sakuma I; Fukui Y; Kaneko A; Fujie T; Taguchi K; Nagaoka S
    Artif Organs; 1991 Apr; 15(2):86-9. PubMed ID: 2036067
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optical chemical sensors for environmental control and system management.
    Tabacco MB; DiGiuseppe TG
    Adv Space Res; 1996; 18(4-5):125-34. PubMed ID: 11538788
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hand-held optical sensor using denatured antibody coated electro-active polymer for ultra-trace detection of copper in blood serum and environmental samples.
    Chandra S; Dhawangale A; Mukherji S
    Biosens Bioelectron; 2018 Jul; 110():38-43. PubMed ID: 29587192
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An optode sensor for Cu2+ with high selectivity based on porphyrin derivative appended with bipyridine.
    Luo HY; Zhang XB; Jiang JH; Li CY; Peng J; Shen GL; Yu RQ
    Anal Sci; 2007 May; 23(5):551-5. PubMed ID: 17495400
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Polymer membranes in clinical sensor applications. III. Hydrogels as reactive matrix membranes in fibre optic sensors.
    Davies ML; Murphy SM; Hamilton CJ; Tighe BJ
    Biomaterials; 1992; 13(14):991-9. PubMed ID: 1472595
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fiber-optic sensor for iodine based on a covalently immobilized aminobenzanthrone Schiff base.
    Chen LX; Niu CG; Xie ZM; Long YQ; Song XR
    Anal Sci; 2006 Jul; 22(7):977-81. PubMed ID: 16837749
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Miniature sodium-selective ion-exchange optode with fluorescent pH chromoionophores and tunable dynamic range.
    Shortreed M; Bakker E; Kopelman R
    Anal Chem; 1996 Aug; 68(15):2656-62. PubMed ID: 8694263
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A disposable optrode using immobilized tyrosinase films.
    Paranjpe P; Dutta S; Karve M; Padhye S; Narayanaswamy R
    Anal Biochem; 2001 Jul; 294(2):102-7. PubMed ID: 11444804
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Turn-On Fluorescence-Based Fibre Optic Sensor for the Detection of Mercury.
    Nguyen TH; Sun T; Grattan KTV
    Sensors (Basel); 2019 May; 19(9):. PubMed ID: 31075827
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a medical fiber-optic pH sensor based on optical absorption.
    Wolthuis R; McCrae D; Saaski E; Hartl J; Mitchell G
    IEEE Trans Biomed Eng; 1992 May; 39(5):531-7. PubMed ID: 1526644
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An optical fiber sensor for remote pH sensing and imaging.
    Wang J; Wang L
    Appl Spectrosc; 2012 Mar; 66(3):300-3. PubMed ID: 22449307
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.