BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 15942062)

  • 1. Investigation of photon attenuation coefficients for marble.
    Basyigit C; Akkurt I; Kilincarslan S; Akkurt A
    J Radiol Prot; 2005 Jun; 25(2):189-92. PubMed ID: 15942062
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calculation of radiation attenuation coefficients, effective atomic numbers and electron densities for some building materials.
    Damla N; Baltas H; Celik A; Kiris E; Cevik U
    Radiat Prot Dosimetry; 2012 Jul; 150(4):541-9. PubMed ID: 22128356
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Attenuation characteristics of MagnaDense high-density concrete at 6, 10 and 15 mv for use in radiotherapy bunker design.
    Jones MR; Peet DJ; Horton PW
    Health Phys; 2009 Jan; 96(1):67-75. PubMed ID: 19066488
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Materials analysis using x-ray linear attenuation coefficient measurements at four photon energies.
    Midgley SM
    Phys Med Biol; 2005 Sep; 50(17):4139-57. PubMed ID: 16177536
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low-energy broad-beam photon shielding data for constituents of concrete.
    Ogundare FO; Ogundele SA; Akerele OO; Balogun FA
    J Appl Clin Med Phys; 2012 Mar; 13(2):3525. PubMed ID: 22402377
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experimental investigation of gamma-ray attenuation in Jordanian building materials using HPGe-spectrometer.
    Awadallah MI; Imran MM
    J Environ Radioact; 2007; 94(3):129-36. PubMed ID: 17368884
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of gas concrete materials used in buildings of Turkey.
    Damla N; Cevik U; Kobya AI; Celik A; Van Grieken R; Kobya Y
    J Hazard Mater; 2009 Sep; 168(2-3):681-7. PubMed ID: 19297097
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of natural radioactivity of sand used in Turkey.
    Cevik U; Damla N; Kobya AI; Celik N; Celik A; Van AA
    J Radiol Prot; 2009 Mar; 29(1):61-74. PubMed ID: 19225183
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparative studies of different concretes on the basis of some photon interaction parameters.
    Kaur U; Sharma JK; Singh PS; Singh T
    Appl Radiat Isot; 2012 Jan; 70(1):233-40. PubMed ID: 21820906
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calculations of neutron and photon source terms and attenuation profiles for the generic design of the SPEAR3 storage ring shield.
    Rokni SH; Khater H; Liu JC; Mao S; Vincke H
    Radiat Prot Dosimetry; 2005; 115(1-4):200-6. PubMed ID: 16381712
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mass attenuation coefficients of natural Rhizophora spp. wood for X-rays in the 15.77-25.27 keV range.
    Shakhreet BZ; Bauk S; Tajuddin AA; Shukri A
    Radiat Prot Dosimetry; 2009 Jul; 135(1):47-53. PubMed ID: 19482883
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Verification of some building materials as gamma-ray shields.
    Mann KS; Singla J; Kumar V; Sidhu GS
    Radiat Prot Dosimetry; 2012 Aug; 151(1):183-95. PubMed ID: 22223719
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Energy response of LiF and Mg2SiO4 TLDs to 10-150 keV monoenergetic photons.
    Konnai A; Nariyama N; Ohnishi S; Odano N
    Radiat Prot Dosimetry; 2005; 115(1-4):334-6. PubMed ID: 16381741
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-performance heavy concrete as a multi-purpose shield.
    Mortazavi SM; Mosleh-Shirazi MA; Roshan-Shomal P; Raadpey N; Baradaran-Ghahfarokhi M
    Radiat Prot Dosimetry; 2010 Dec; 142(2-4):120-4. PubMed ID: 21036811
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fluence to absorbed foetal dose conversion coefficients for photons in 50 keV-10 GeV calculated using RPI-P models.
    Taranenko V; Xu XG
    Radiat Prot Dosimetry; 2008; 131(2):159-66. PubMed ID: 18519553
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Estimated fluence-to-absorbed dose conversion coefficients for use in radiological protection of embryo and foetus against external exposure to photons from 50 keV to 10 GeV.
    Chen J
    Radiat Prot Dosimetry; 2006; 121(4):358-63. PubMed ID: 16698964
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The use of high-density concretes in radiotherapy treatment room design.
    Facure A; Silva AX
    Appl Radiat Isot; 2007 Sep; 65(9):1023-8. PubMed ID: 17531498
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigation of photon shielding property changes in curing high density concrete.
    Marsh MB; Peters C; Rawluk N; Schreiner LJ
    Health Phys; 2013 Oct; 105(4):318-25. PubMed ID: 23982607
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of mass attenuation coefficients of Rhizophora spp. binderless particleboards in the 16.59-25.26 keV photon energy range and their density profile using x-ray computed tomography.
    Marashdeh MW; Bauk S; Tajuddin AA; Hashim R
    Appl Radiat Isot; 2012 Apr; 70(4):656-62. PubMed ID: 22304963
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.
    Jaradat AK; Biggs PJ
    Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.