231 related articles for article (PubMed ID: 15943703)
21. Implementation of a proficiency testing programme for bacterial screening in platelet preparations in Canada.
Mastronardi C; Martincic I; Ramírez-Arcos S
Vox Sang; 2007 Aug; 93(2):131-8. PubMed ID: 17683356
[TBL] [Abstract][Full Text] [Related]
22. Evaluation of BacT/ALERT plastic culture bottles for use in testing pooled whole blood-derived leukoreduced platelet-rich plasma platelets with a single contaminated unit.
Brecher ME; Hay SN; Rose AD; Rothenberg SJ
Transfusion; 2005 Sep; 45(9):1512-7. PubMed ID: 16131385
[TBL] [Abstract][Full Text] [Related]
23. Validation of BacT/ALERT plastic culture bottles for use in testing of whole-blood-derived leukoreduced platelet-rich-plasma-derived platelets.
Brecher ME; Hay SN; Rothenberg SJ
Transfusion; 2004 Aug; 44(8):1174-8. PubMed ID: 15265121
[TBL] [Abstract][Full Text] [Related]
24. Use of a solid-phase fluorescent cytometric technique for the detection of bacteria in platelet concentrates.
McDonald CP; Colvin J; Robbins S; Barbara JA
Transfus Med; 2005 Jun; 15(3):175-83. PubMed ID: 15943702
[TBL] [Abstract][Full Text] [Related]
25. Improving the performance of culture-based bacterial screening by increasing the sample volume from 4 mL to 8 mL in aerobic culture bottles.
Souza S; Bravo M; Poulin T; Vanderpool S; Kamel H; Tomasulo P; Su LL
Transfusion; 2012 Jul; 52(7):1576-82. PubMed ID: 22211365
[TBL] [Abstract][Full Text] [Related]
26. Bacterial detection in platelet components and the rationale for pathogen inactivation: a blood center perspective.
Benjamin RJ
J Clin Apher; 2005 Jul; 20(2):117-22. PubMed ID: 15880366
[No Abstract] [Full Text] [Related]
27. FACS technology used in a new rapid bacterial detection method.
Schmidt M; Hourfar MK; Nicol SB; Spengler HP; Montag T; Seifried E
Transfus Med; 2006 Oct; 16(5):355-61. PubMed ID: 16999759
[TBL] [Abstract][Full Text] [Related]
28. Two-year experience with aerobic culturing of apheresis and whole blood-derived platelets.
Kleinman SH; Kamel HT; Harpool DR; Vanderpool SK; Custer B; Wiltbank TB; Nguyen KA; Tomasulo PA
Transfusion; 2006 Oct; 46(10):1787-94. PubMed ID: 17002636
[TBL] [Abstract][Full Text] [Related]
29. Imported platelets demonstrate decreased pH and glucose by reagent strip testing when compared to locally derived platelets.
Clark P; Parsons TM; Boyd JC; Dewey P; Mintz PD
Ann Clin Lab Sci; 2006; 36(4):443-6. PubMed ID: 17127732
[TBL] [Abstract][Full Text] [Related]
30. Evaluation of the Scansystem method for detection of bacterially contaminated platelets.
Jacobs MR; Bajaksouzian S; Windau A; Palavecino EL; Yomtovian R
Transfusion; 2005 Feb; 45(2):265-9. PubMed ID: 15660837
[TBL] [Abstract][Full Text] [Related]
31. [Growth and detection of aerobic bacterial pathogens in BacT/Alert FA, BacT/Alert SA, Bactec Plus Aerobic/F and Bactec Standard Aerobic/F].
Cermák P; Sedláková P; Mejstríková L; Mazurová J
Klin Mikrobiol Infekc Lek; 2006 Aug; 12(4):156-60. PubMed ID: 16958021
[TBL] [Abstract][Full Text] [Related]
32. Comparison of the BACTEC 9240 and BacT/Alert blood culture systems for detection of bacterial contamination in platelet concentrates.
Riedel S; Siwek G; Beekmann SE; Richter SS; Raife T; Doern GV
J Clin Microbiol; 2006 Jun; 44(6):2262-4. PubMed ID: 16757635
[TBL] [Abstract][Full Text] [Related]
33. Pall eBDS: an enhanced bacterial detection system for screening platelet concentrates.
McDonald CP; Pearce S; Wilkins K; Colvin J; Robbins S; Colley L; Taylor J; Barbara JA
Transfus Med; 2005 Aug; 15(4):259-68. PubMed ID: 16101803
[TBL] [Abstract][Full Text] [Related]
34. Evaluation of the BacT/Alert automated blood culture system for detecting bacteria and measuring their growth kinetics in leucodepleted and non-leucodepleted platelet concentrates.
McDonald CP; Roy A; Lowe P; Robbins S; Hartley S; Barbara JA
Vox Sang; 2001 Oct; 81(3):154-60. PubMed ID: 11703857
[TBL] [Abstract][Full Text] [Related]
35. Screening of single-donor apheresis platelets for bacterial contamination: the PASSPORT study results.
Dumont LJ; Kleinman S; Murphy JR; Lippincott R; Schuyler R; Houghton J; Metzel P
Transfusion; 2010 Mar; 50(3):589-99. PubMed ID: 19929862
[TBL] [Abstract][Full Text] [Related]
36. Value of anaerobic culture in bacterial surveillance program for platelet concentrates.
Lee CK; Ho PL; Lee KY; Tsui GT; Chua E; Tsoi WC; Lin CK
Transfusion; 2008 Dec; 48(12):2606-11. PubMed ID: 18694462
[TBL] [Abstract][Full Text] [Related]
37. Blood surveillance and detection on platelet bacterial contamination associated with septic events.
Hsueh JC; Ho CF; Chang SH; Pan FZ; Chen SC; Shi MD; Chien ST
Transfus Med; 2009 Dec; 19(6):350-6. PubMed ID: 19719474
[TBL] [Abstract][Full Text] [Related]
38. Evaluation of the 3D BacT/ALERT automated culture system for the detection of microbial contamination of platelet concentrates.
McDonald CP; Rogers A; Cox M; Smith R; Roy A; Robbins S; Hartley S; Barbara JA; Rothenberg S; Stutzman L; Widders G
Transfus Med; 2002 Oct; 12(5):303-9. PubMed ID: 12383336
[TBL] [Abstract][Full Text] [Related]
39. Extension of platelet shelf life from 4 to 5 days by implementation of a new screening strategy in Germany.
Sireis W; Rüster B; Daiss C; Hourfar MK; Capalbo G; Pfeiffer HU; Janetzko K; Goebel M; Kempf VA; Seifried E; Schmidt M
Vox Sang; 2011 Oct; 101(3):191-9. PubMed ID: 21517896
[TBL] [Abstract][Full Text] [Related]
40. Bacterial screening of outdated buffy coat platelet pools using a culture system and a rapid immunoassay.
Ramírez-Arcos S; Kou Y; Mastronardi C; Perkins H; Goldman M
Transfusion; 2011 Dec; 51(12):2566-72. PubMed ID: 21883268
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]