These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
154 related articles for article (PubMed ID: 15949199)
1. Cling wrap, an innovative intervention for temperature maintenance and reduction of insensible water loss in very low-birthweight babies nursed under radiant warmers: a randomized, controlled trial. Kaushal M; Agarwal R; Aggarwal R; Singal A; Upadhyay M; Srinivas V; Paul VK; Deorari AK Ann Trop Paediatr; 2005 Jun; 25(2):111-8. PubMed ID: 15949199 [TBL] [Abstract][Full Text] [Related]
2. Increased insensible water loss in newborn infants nursed under radiant heaters. Jones RW; Rochefort MJ; Baum JD Br Med J; 1976 Dec; 2(6048):1347-50. PubMed ID: 1000228 [TBL] [Abstract][Full Text] [Related]
3. Reduction of oxygen consumption, insensible water loss, and radiant heat demand with use of a plastic blanket for low-birth-weight infants under radiant warmers. Baumgart S Pediatrics; 1984 Dec; 74(6):1022-8. PubMed ID: 6504622 [TBL] [Abstract][Full Text] [Related]
4. Reduction of skin water loss in the newborn. II. Clinical trial of two methods in very low birthweight babies. Brice JE; Rutter N; Hull D Arch Dis Child; 1981 Sep; 56(9):673-5. PubMed ID: 7294869 [TBL] [Abstract][Full Text] [Related]
5. Effect of polyethylene bag to prevent heat loss in preterm infants at birth: a randomized controlled trial. Chantaroj S; Techasatid W J Med Assoc Thai; 2011 Dec; 94 Suppl 7():S32-7. PubMed ID: 22619904 [TBL] [Abstract][Full Text] [Related]
6. Heat loss prevention (help) after birth in preterm infants using vinyl isolation bag or polyethylene wrap. Çağlar S; Gözen D; Ince Z J Obstet Gynecol Neonatal Nurs; 2014; 43(2):216-23. PubMed ID: 24617764 [TBL] [Abstract][Full Text] [Related]
7. Randomized controlled trial of vinyl bags versus thermal mattress to prevent hypothermia in extremely low-gestational-age infants. Mathew B; Lakshminrusimha S; Sengupta S; Carrion V Am J Perinatol; 2013 Apr; 30(4):317-22. PubMed ID: 22893555 [TBL] [Abstract][Full Text] [Related]
8. Polyethylene skin wrapping accelerates recovery from hypothermia in very low-birthweight infants. Duman N; Utkutan S; Kumral A; Köroğlu TF; Ozkan H Pediatr Int; 2006 Feb; 48(1):29-32. PubMed ID: 16490066 [TBL] [Abstract][Full Text] [Related]
9. A simple device for reducing insensible water loss in low-birth-weight infants. Marks KH; Friedman Z; Maisels MJ Pediatrics; 1977 Aug; 60(2):223-6. PubMed ID: 887337 [TBL] [Abstract][Full Text] [Related]
10. The heat balance of small babies nursed in incubators and under radiant warmers. Wheldon AE; Rutter N Early Hum Dev; 1982 Apr; 6(2):131-43. PubMed ID: 7094851 [TBL] [Abstract][Full Text] [Related]
11. Euthermia in Stable Preterm Babies: 'Cocooning' for Warmth! - A Randomized Controlled Trial. Vijayan S; Pournami F; Prabhakar J; Jain N J Trop Pediatr; 2020 Feb; 66(1):15-23. PubMed ID: 31034030 [TBL] [Abstract][Full Text] [Related]
12. Improved care and growth outcomes by using hybrid humidified incubators in very preterm infants. Kim SM; Lee EY; Chen J; Ringer SA Pediatrics; 2010 Jan; 125(1):e137-45. PubMed ID: 20026493 [TBL] [Abstract][Full Text] [Related]
13. Thermal Blanket to Improve Thermoregulation in Preterm Infants: A Randomized Controlled Trial. Hsu KH; Chiang MC; Lin SW; Lin JJ; Wang YC; Lien R Pediatr Crit Care Med; 2015 Sep; 16(7):637-43. PubMed ID: 25901548 [TBL] [Abstract][Full Text] [Related]
14. Reducing hypothermia in preterm infants with polyethylene wrap. Rohana J; Khairina W; Boo NY; Shareena I Pediatr Int; 2011 Aug; 53(4):468-74. PubMed ID: 21105964 [TBL] [Abstract][Full Text] [Related]
15. Admission temperatures following radiant warmer or incubator transport for preterm infants <28 weeks: a randomised study. Meyer MP; Bold GT Arch Dis Child Fetal Neonatal Ed; 2007 Jul; 92(4):F295-7. PubMed ID: 17158144 [TBL] [Abstract][Full Text] [Related]
16. Keeping babies warm: a non-inferiority trial of a conductive thermal mattress. Bhat SR; Meng NF; Kumar K; Nagesh KN; Kawale A; Bhutani VK Arch Dis Child Fetal Neonatal Ed; 2015 Jul; 100(4):F309-12. PubMed ID: 25791056 [TBL] [Abstract][Full Text] [Related]
17. 'Cling film' to wrap herniated loops. Bhide SS Indian Pediatr; 2007 Jun; 44(6):469. PubMed ID: 17620705 [No Abstract] [Full Text] [Related]
18. Improving neonatal unit admission temperatures in preterm babies: exothermic mattresses, polythene bags or a traditional approach? Singh A; Duckett J; Newton T; Watkinson M J Perinatol; 2010 Jan; 30(1):45-9. PubMed ID: 19641512 [TBL] [Abstract][Full Text] [Related]
19. Effect of polyethylene occlusive skin wrapping on heat loss in very low birth weight infants at delivery: a randomized trial. Vohra S; Frent G; Campbell V; Abbott M; Whyte R J Pediatr; 1999 May; 134(5):547-51. PubMed ID: 10228287 [TBL] [Abstract][Full Text] [Related]
20. Infant incubators and radiant warmers. Bell EF Early Hum Dev; 1983 Oct; 8(3-4):351-75. PubMed ID: 6641579 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]