BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 15957625)

  • 1. Initial transcutaneous PCO2 overshoot with ear probe at 42 degrees C.
    Kagawa S; Otani N; Kamide M; Gisiger PA; Eberhard P; Severinghaus JW
    J Clin Monit Comput; 2004 Dec; 18(5-6):343-5. PubMed ID: 15957625
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Combining transcutaneous blood gas measurement and pulse oximetry.
    Eberhard P; Gisiger PA; Gardaz JP; Spahn DR
    Anesth Analg; 2002 Jan; 94(1 Suppl):S76-80. PubMed ID: 11900043
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia.
    Rohling R; Biro P
    J Clin Monit Comput; 1999 Jan; 15(1):23-7. PubMed ID: 12578058
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Method of evading the overshoot phenomenon of transcutaneous P(CO2) measurement at the ear lobe].
    Hirabayashi M; Otani N; Kagawa S; Kamide M
    Masui; 2006 Aug; 55(8):1018-22. PubMed ID: 16910488
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcutaneous PCO2 monitoring in critically ill adults: clinical evaluation of a new sensor.
    Bendjelid K; Schütz N; Stotz M; Gerard I; Suter PM; Romand JA
    Crit Care Med; 2005 Oct; 33(10):2203-6. PubMed ID: 16215371
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of transcutaneous PCO2 in critically ill patients.
    Rithalia SV; Ng YY; Tinker J
    Resuscitation; 1982 Mar; 10(1):13-8. PubMed ID: 6291114
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of electrode temperatures on monitoring of transcutaneous carbon dioxide (TcPCO2) in prematures.
    Vesterager P
    Biotelem Patient Monit; 1982; 9(1):18-27. PubMed ID: 6809069
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The revised digital transcutaneous PCO2/SpO2 ear sensor is a reliable noninvasive monitoring tool in patients after cardiac surgery.
    Roediger R; Beck-Schimmer B; Theusinger OM; Rusch D; Seifert B; Spahn DR; Schmid ER; Baulig W
    J Cardiothorac Vasc Anesth; 2011 Apr; 25(2):243-9. PubMed ID: 20851636
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Is continuous transcutaneous monitoring of PCO2 (TcPCO2) over 8 h reliable in adults?
    Janssens JP; Perrin E; Bennani I; de Muralt B; Titelion V; Picaud C
    Respir Med; 2001 May; 95(5):331-5. PubMed ID: 11392572
    [TBL] [Abstract][Full Text] [Related]  

  • 10. tcPCO2 electrode design, calibration and temperature gradient problems.
    Severinghaus JW; Stafford M; Bradley AF
    Acta Anaesthesiol Scand Suppl; 1978; 68():118-22. PubMed ID: 29431
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transcutaneous Carbon Dioxide Monitoring with Reduced-Temperature Probes in Very Low Birth Weight Infants.
    Aly S; El-Dib M; Mohamed M; Aly H
    Am J Perinatol; 2017 Apr; 34(5):480-485. PubMed ID: 27673754
    [No Abstract]   [Full Text] [Related]  

  • 12. Skin temperature influence on transcutaneous carbon dioxide (CO
    Dervieux E; Guerrero F; Uhring W; Giroux-Metgès MA; Théron M
    Front Physiol; 2023; 14():1293752. PubMed ID: 38321986
    [No Abstract]   [Full Text] [Related]  

  • 13. Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia.
    Nishiyama T; Nakamura S; Yamashita K
    Eur J Anaesthesiol; 2006 Dec; 23(12):1049-54. PubMed ID: 16824244
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of the transcutaneous electrode temperature on the accuracy of transcutaneous carbon dioxide tension.
    Sørensen LC; Brage-Andersen L; Greisen G
    Scand J Clin Lab Invest; 2011 Nov; 71(7):548-52. PubMed ID: 21732731
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.
    Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M
    Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance of a digital PCO2/SPO2 ear sensor.
    Kocher S; Rohling R; Tschupp A
    J Clin Monit Comput; 2004 Apr; 18(2):75-9. PubMed ID: 15362268
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental and clinical evaluation of a noninvasive reflectance pulse oximeter sensor.
    Takatani S; Davies C; Sakakibara N; Zurick A; Kraenzler E; Golding LR; Noon GP; Nose Y; DeBakey ME
    J Clin Monit; 1992 Oct; 8(4):257-66. PubMed ID: 1453185
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of a new combined transcutaneous tcPCO
    van Wijk JJ; van Weteringen W; Hoeks SE; Staals LM
    Paediatr Anaesth; 2022 Mar; 32(3):429-435. PubMed ID: 34882905
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device.
    Janssens JP; Howarth-Frey C; Chevrolet JC; Abajo B; Rochat T
    Chest; 1998 Mar; 113(3):768-73. PubMed ID: 9515855
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Increasing arterial carbon dioxide tension: influence on transcutaneous carbon dioxide tension measurements.
    Martin RJ; Beoglos A; Miller MJ; DiFiore JM; Robertson SS; Carlo WA
    Pediatrics; 1988 May; 81(5):684-7. PubMed ID: 3128769
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.