173 related articles for article (PubMed ID: 15960066)
21. Evaluation of left ventricular volumes and ejection fraction by automated gated myocardial SPECT versus cardiovascular magnetic resonance.
Persson E; Carlsson M; Palmer J; Pahlm O; Arheden H
Clin Physiol Funct Imaging; 2005 May; 25(3):135-41. PubMed ID: 15888092
[TBL] [Abstract][Full Text] [Related]
22. Limited performance of quantitative assessment of myocardial function by thallium-201 gated myocardial single-photon emission tomography.
Lee DS; Ahn JY; Kim SK; Oh BH; Seo JD; Chung JK; Lee MC
Eur J Nucl Med; 2000 Feb; 27(2):185-91. PubMed ID: 10755724
[TBL] [Abstract][Full Text] [Related]
23. Evaluation of the left ventricular hemodynamic function and myocardial perfusion by gated single photon emission tomography, in patients with type 1 diabetes mellitus; prodromal signs of cardiovascular disease after four years.
Chrapko B; Kowalczyk M; Nocuń A; Nowakowski A; Zaorska-Rajca J
Hell J Nucl Med; 2006; 9(2):90-3. PubMed ID: 16894411
[TBL] [Abstract][Full Text] [Related]
24. Ischaemic related transitory left ventricular dysfunction in 201Tl gated SPECT.
del Val Gómez M; Gallardo FG; San Martín MA; Garcia A; Terol I
Nucl Med Commun; 2005 Jul; 26(7):601-5. PubMed ID: 15942480
[TBL] [Abstract][Full Text] [Related]
25. Comparison of gated SPECT, echocardiography and cardiac magnetic resonance imaging for the assessment of left ventricular ejection fraction and volumes.
Demir H; Tan YZ; Kozdag G; Isgoren S; Anik Y; Ural D; Demirci A; Berk F
Ann Saudi Med; 2007; 27(6):415-20. PubMed ID: 18059128
[TBL] [Abstract][Full Text] [Related]
26. Comparison of Gated SPECT Myocardial Perfusion Imaging with Echocardiography for the Measurement of Left Ventricular Volumes and Ejection Fraction in Patients With Severe Heart Failure.
Shojaeifard M; Ghaedian T; Yaghoobi N; Malek H; Firoozabadi H; Bitarafan-Rajabi A; Haghjoo M; Amin A; Azizian N; Rastgou F
Res Cardiovasc Med; 2016 Feb; 5(1):e29005. PubMed ID: 26889455
[TBL] [Abstract][Full Text] [Related]
27. Evaluation of left ventricular function and volume in patients with dilated cardiomyopathy: gated myocardial single-photon emission tomography (SPECT) versus echocardiography.
Berk F; Isgoren S; Demir H; Kozdag G; Ural D; Komsuoglu B
Ann Saudi Med; 2005; 25(3):198-204. PubMed ID: 16119519
[TBL] [Abstract][Full Text] [Related]
28. Prone versus supine patient positioning during gated 99mTc-sestamibi SPECT: effect on left ventricular volumes, ejection fraction, and heart rate.
Schaefer WM; Lipke CS; Kühl HP; Koch KC; Kaiser HJ; Reinartz P; Nowak B; Buell U
J Nucl Med; 2004 Dec; 45(12):2016-20. PubMed ID: 15585475
[TBL] [Abstract][Full Text] [Related]
29. Reproducibility of Tl-201 and Tc-99m sestamibi gated myocardial perfusion SPECT measurement of myocardial function.
Hyun IY; Kwan J; Park KS; Lee WH
J Nucl Cardiol; 2001; 8(2):182-7. PubMed ID: 11295696
[TBL] [Abstract][Full Text] [Related]
30. Quantifying transient ischemic dilation using gated SPECT.
Heston TF; Sigg DM
J Nucl Med; 2005 Dec; 46(12):1990-6. PubMed ID: 16330561
[TBL] [Abstract][Full Text] [Related]
31. Assessment of left ventricular volumes, ejection fraction and mass. Comparison of model-based analysis of ECG-gated (⁹⁹m)Tc-SPECT and ¹⁸F-FDG-PET.
Khorsand A; Gyöngyösi M; Sochor H; Maurer G; Karanikas G; Dudczak R; Schuster E; Porenta G; Graf S
Nuklearmedizin; 2011; 50(1):9-14. PubMed ID: 21165540
[TBL] [Abstract][Full Text] [Related]
32. Effects of myocardial perfusion abnormalities on the accuracy of left ventricular volume and ejection fraction measured by thallium-201 gated single-photon emission tomography: comparison with echocardiography as the reference standard.
Kurisu S; Iwasaki T; Abe N; Tamura M; Ikenaga H; Watanabe N; Higaki T; Shimonaga T; Ishibashi K; Dohi Y; Fukuda Y; Kihara Y
Nucl Med Commun; 2015 Nov; 36(11):1127-33. PubMed ID: 26313313
[TBL] [Abstract][Full Text] [Related]
33. Comparison of two three-dimensional gated SPECT methods with thallium in patients with large myocardial infarction.
Véra P; Koning R; Cribier A; Manrique A
J Nucl Cardiol; 2000; 7(4):312-9. PubMed ID: 10958272
[TBL] [Abstract][Full Text] [Related]
34. The influence of post-exercise cardiac changes on thallium-gated myocardial perfusion scintigraphy findings in normal subjects.
Aktaş A; Yalcin H; Koyuncu A; Aydinalp A; Müderrisoglu H
Nucl Med Commun; 2005 Feb; 26(2):109-14. PubMed ID: 15657502
[TBL] [Abstract][Full Text] [Related]
35. Repeatability of automatic left ventricular cavity volume measurements from myocardial perfusion SPECT.
Germano G; Kavanagh PB; Kavanagh JT; Wishner SH; Berman DS; Kavanagh GJ
J Nucl Cardiol; 1998; 5(5):477-83. PubMed ID: 9796894
[TBL] [Abstract][Full Text] [Related]
36. Cardiac functional analysis with multi-detector row CT and segmental reconstruction algorithm: comparison with echocardiography, SPECT, and MR imaging.
Yamamuro M; Tadamura E; Kubo S; Toyoda H; Nishina T; Ohba M; Hosokawa R; Kimura T; Tamaki N; Komeda M; Kita T; Konishi J
Radiology; 2005 Feb; 234(2):381-90. PubMed ID: 15670995
[TBL] [Abstract][Full Text] [Related]
37. Influence of left ventricular geometry on thallium-201 gated single-photon emission tomographic findings in patients with known or suspected coronary artery disease.
Kurisu S; Iwasaki T; Ikenaga H; Watanabe N; Higaki T; Shimonaga T; Ishibashi K; Mitsuba N; Dohi Y; Kihara Y
Ann Nucl Med; 2014 Feb; 28(2):120-7. PubMed ID: 24254429
[TBL] [Abstract][Full Text] [Related]
38. Thallium-201 gated single-photon emission tomography for the assessment of left ventricular ejection fraction and regional wall motion abnormalities in comparison with two-dimensional echocardiography.
Bacher-Stier C; Müller S; Pachinger O; Strolz S; Erler H; Moncayo R; Wenger M; Donnemiller E; Riccabona G
Eur J Nucl Med; 1999 Dec; 26(12):1533-40. PubMed ID: 10638403
[TBL] [Abstract][Full Text] [Related]
39. Comparison of left ventricular functional parameters obtained from three different commercial automated software cardiac quantification program packages and their intraobserver reproducibility.
Dostbil Z; Arıtürk Z; Cil H; Elbey MA; Tekbaş E; Yazıcı M; Yıldız I; Taşdemir B
Ann Nucl Med; 2011 Feb; 25(2):125-31. PubMed ID: 21104169
[TBL] [Abstract][Full Text] [Related]
40. Gated cardiac 13N-NH3 PET for assessment of left ventricular volumes, mass, and ejection fraction: comparison with electrocardiography-gated 18F-FDG PET.
Khorsand A; Graf S; Eidherr H; Wadsak W; Kletter K; Sochor H; Schuster E; Porenta G
J Nucl Med; 2005 Dec; 46(12):2009-13. PubMed ID: 16330564
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]