These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 15973512)

  • 1. Serial repositioning of a Günther tulip retrievable inferior vena cava filter in a pediatric patient.
    Haider EA; Rosen JC; Torres C; Valenti DA
    Pediatr Radiol; 2005 Nov; 35(11):1135-8. PubMed ID: 15973512
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Removal of a Günther Tulip retrievable inferior vena cava filter after 147 days in a pediatric patient.
    Mody RN; Stokes LS; Bream PR; Spottswood SE
    Pediatr Radiol; 2006 May; 36(5):440-4. PubMed ID: 16532347
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Günther Tulip retrievable filter: prolonged temporary filtration by repositioning within the inferior vena cava.
    de Gregorio MA; Gamboa P; Gimeno MJ; Madariaga B; Tobío R; Herrera M; Medrano J; Mainar A; Alfonso R
    J Vasc Interv Radiol; 2003 Oct; 14(10):1259-65. PubMed ID: 14551272
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of retrievable compared to permanent inferior vena cava filters: a single-institution experience.
    Van Ha TG; Chien AS; Funaki BS; Lorenz J; Piano G; Shen M; Leef J
    Cardiovasc Intervent Radiol; 2008; 31(2):308-15. PubMed ID: 17955289
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Extended interval for retrieval of Günther Tulip filters.
    Terhaar OA; Lyon SM; Given MF; Foster AE; Mc Grath F; Lee MJ
    J Vasc Interv Radiol; 2004 Nov; 15(11):1257-62. PubMed ID: 15525745
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retrievable Günther Tulip Vena Cava Filter in the prevention of pulmonary embolism in patients with acute deep venous thrombosis in perinatal period.
    Köcher M; Krcova V; Cerna M; Prochazka M
    Eur J Radiol; 2009 Apr; 70(1):165-9. PubMed ID: 18242910
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Günther Tulip and Celect IVC filters in multiple-trauma patients.
    Rosenthal D; Kochupura PV; Wellons ED; Burkett AB; Methodius-Rayford WC
    J Endovasc Ther; 2009 Aug; 16(4):494-9. PubMed ID: 19702346
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Perforation of the IVC: rule rather than exception after longer indwelling times for the Günther Tulip and Celect retrievable filters.
    Durack JC; Westphalen AC; Kekulawela S; Bhanu SB; Avrin DE; Gordon RL; Kerlan RK
    Cardiovasc Intervent Radiol; 2012 Apr; 35(2):299-308. PubMed ID: 21448771
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safety and efficacy of the Gunther Tulip retrievable vena cava filter: midterm outcomes.
    Hoffer EK; Mueller RJ; Luciano MR; Lee NN; Michaels AT; Gemery JM
    Cardiovasc Intervent Radiol; 2013 Aug; 36(4):998-1005. PubMed ID: 23180324
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical comparison of two optional vena cava filters.
    Keller IS; Meier C; Pfiffner R; Keller E; Pfammatter T
    J Vasc Interv Radiol; 2007 Apr; 18(4):505-11. PubMed ID: 17446541
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gunther Tulip retrievable inferior vena caval filters: indications, efficacy, retrieval, and complications.
    Looby S; Given MF; Geoghegan T; McErlean A; Lee MJ
    Cardiovasc Intervent Radiol; 2007; 30(1):59-65. PubMed ID: 17122885
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term retrievability of IVC filters: should we abandon permanent devices?
    Berczi V; Bottomley JR; Thomas SM; Taneja S; Gaines PA; Cleveland TJ
    Cardiovasc Intervent Radiol; 2007; 30(5):820-7. PubMed ID: 17763901
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Early technical and clinical results with retrievable inferior vena caval filters.
    Lam RC; Bush RL; Lin PH; Lumsden AB
    Vascular; 2004; 12(4):233-7. PubMed ID: 15704317
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Retrieval of Gunther Tulip optional vena cava filters 30 days after implantation: a prospective clinical study.
    De Gregorio MA; Gamboa P; Bonilla DL; Sanchez M; Higuera MT; Medrano J; Mainar A; Lostalé F; Laborda A
    J Vasc Interv Radiol; 2006 Nov; 17(11 Pt 1):1781-9. PubMed ID: 17142708
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Successful retrieval of a Gunther tulip vena cava filter with the assistance of a curved sheath introducer.
    Yamagami T; Kato T; Nishimura T
    J Vasc Interv Radiol; 2005 Dec; 16(12):1760-2. PubMed ID: 16371548
    [No Abstract]   [Full Text] [Related]  

  • 16. OptEase retrievable inferior vena cava filter: initial multicenter experience.
    Rosenthal D; Swischuk JL; Cohen SA; Wellons ED
    Vascular; 2005; 13(5):286-9. PubMed ID: 16288703
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Symptomatic perforation of a retrievable inferior vena cava filter after a dwell time of 5 years.
    Parkin E; Serracino-Inglott F; Chalmers N; Smyth V
    J Vasc Surg; 2009 Aug; 50(2):417-9. PubMed ID: 19631878
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of rigid bronchoscopic forceps in the difficult retrieval of the Günther Tulip inferior vena cava filter.
    Burke CT; Dixon RG; Stavas JM
    J Vasc Interv Radiol; 2007 Oct; 18(10):1319-23. PubMed ID: 17911526
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcomes with retrievable inferior vena cava filters: a multicenter study.
    Ray CE; Mitchell E; Zipser S; Kao EY; Brown CF; Moneta GL
    J Vasc Interv Radiol; 2006 Oct; 17(10):1595-604. PubMed ID: 17057000
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Inferior vena cava filter removal after 317-day implantation.
    Binkert CA; Bansal A; Gates JD
    J Vasc Interv Radiol; 2005 Mar; 16(3):395-8. PubMed ID: 15758137
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.