162 related articles for article (PubMed ID: 1597389)
1. Photoneutron production in the primary barriers of medical accelerator rooms.
McGinley PH
Health Phys; 1992 Apr; 62(4):359-62. PubMed ID: 1597389
[TBL] [Abstract][Full Text] [Related]
2. On the production of neutrons in laminated barriers for 10 MV medical accelerator rooms.
Facure A; da Silva AX; da Rosa LA; Cardoso SC; Rezende GF
Med Phys; 2008 Jul; 35(7):3285-92. PubMed ID: 18697553
[TBL] [Abstract][Full Text] [Related]
3. Photoneutron fields in medical accelerator rooms with primary barriers constructed of concrete and metals.
McGinley PH
Health Phys; 1992 Dec; 63(6):698-701. PubMed ID: 1428893
[TBL] [Abstract][Full Text] [Related]
4. Bremsstrahlung and photoneutron production in a steel shield for 15-22-MeV clinical electron beams.
Fujita Y; Myojoyama A; Saitoh H
Radiat Prot Dosimetry; 2015 Feb; 163(2):148-59. PubMed ID: 24821930
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of the effectiveness of steel for shielding photoneutrons produced in medical linear accelerators: A Monte Carlo particle transport study.
Moghaddasi L; Colyer C
Phys Med; 2022 Jun; 98():53-62. PubMed ID: 35490530
[TBL] [Abstract][Full Text] [Related]
6. Monte Carlo simulation of neutron dose equivalent by photoneutron production inside the primary barriers of a radiotherapy vault.
Choi CH; Park SY; Park JM; Chun M; Kim JI
Phys Med; 2018 Apr; 48():1-5. PubMed ID: 29728220
[TBL] [Abstract][Full Text] [Related]
7. Doses to patients from photoneutrons emitted in a medical linear accelerator.
Saeed MK; Moustafa O; Yasin OA; Tuniz C; Habbani FI
Radiat Prot Dosimetry; 2009 Feb; 133(3):130-5. PubMed ID: 19287045
[TBL] [Abstract][Full Text] [Related]
8. Laminated primary ceiling barriers for medical accelerator rooms.
McGinley PH; Butker EK
Phys Med Biol; 1994 Sep; 39(9):1331-6. PubMed ID: 15552107
[TBL] [Abstract][Full Text] [Related]
9. The effect of field modifier blocks on the fast photoneutron dose equivalent from two high-energy medical linear accelerators.
Hashemi SM; Hashemi-Malayeri B; Raisali G; Shokrani P; Sharafi AA; Jafarizadeh M
Radiat Prot Dosimetry; 2008; 128(3):359-62. PubMed ID: 17875628
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of the photoneutron field produced in a medical linear accelerator.
Kim HS; Park YH; Koo BC; Kwon JW; Lee JS; Choi HS
Radiat Prot Dosimetry; 2007; 123(3):323-8. PubMed ID: 17077093
[TBL] [Abstract][Full Text] [Related]
11. The influence of shielding reinforcement in a vault with limited dimensions on the neutron dose equivalent in vicinity of medical electron linear accelerator.
Ivkovic A; Faj D; Kasabasic M; Sovilj MP; Krpan I; Branilovic MG; Brkic H
Radiol Oncol; 2020 May; 54(2):247-252. PubMed ID: 32374291
[TBL] [Abstract][Full Text] [Related]
12. Neutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear accelerators.
Followill DS; Stovall MS; Kry SF; Ibbott GS
J Appl Clin Med Phys; 2003; 4(3):189-94. PubMed ID: 12841788
[TBL] [Abstract][Full Text] [Related]
13. Production of neutrons in laminated barriers of radiotherapy rooms: comparison between the analytical methodology and Monte Carlo simulations.
Rezende GF; Da Rosa LA; Facure A
J Appl Clin Med Phys; 2014 Nov; 15(6):5035. PubMed ID: 25493530
[TBL] [Abstract][Full Text] [Related]
14. Bremsstrahlung and Photoneutron leakage from steel shielding board impinged by 12-24 MeV electrons beams.
Fujita Y; Saitoh H; Myojoyama A
J Radiat Res; 2009 Jul; 50(4):363-9. PubMed ID: 19542692
[TBL] [Abstract][Full Text] [Related]
15. The measurement of photoneutron dose in the vicinity of clinical linear accelerators.
Rivera JC; Falcão RC; Dealmeida CE
Radiat Prot Dosimetry; 2008; 130(4):403-9. PubMed ID: 18375468
[TBL] [Abstract][Full Text] [Related]
16. The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator.
Montgomery L; Evans M; Liang L; Maglieri R; Kildea J
Med Phys; 2018 Oct; 45(10):4711-4719. PubMed ID: 30141186
[TBL] [Abstract][Full Text] [Related]
17. Shielding for neutron scattered dose to the fetus in patients treated with 18 MV x-ray beams.
Roy SC; Sandison GA
Med Phys; 2000 Aug; 27(8):1800-3. PubMed ID: 10984226
[TBL] [Abstract][Full Text] [Related]
18. Characteristics of the photoneutron contamination present in a high-energy radiotherapy treatment room.
Garnica-Garza HM
Phys Med Biol; 2005 Feb; 50(3):531-9. PubMed ID: 15773728
[TBL] [Abstract][Full Text] [Related]
19. AMBIENT DOSE EQUIVALENT RECEIVED AT 15 MV LINAC ENVIRONMENTS DUE TO PHOTONEUTRONS CONTAMINATION.
Vagena E; Katsaras P; Theodorou K; Stoulos S
Radiat Prot Dosimetry; 2018 Dec; 182(4):472-479. PubMed ID: 29961846
[TBL] [Abstract][Full Text] [Related]
20. Radiation protection measurements around a 12 MeV mobile dedicated IORT accelerator.
Soriani A; Felici G; Fantini M; Paolucci M; Borla O; Evangelisti G; Benassi M; Strigari L
Med Phys; 2010 Mar; 37(3):995-1003. PubMed ID: 20384235
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]