These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

228 related articles for article (PubMed ID: 15974133)

  • 1. Ultra-short open capillary columns in gas-liquid chromatography.
    Berezkin VG; Lapin AB
    J Chromatogr A; 2005 May; 1075(1-2):197-203. PubMed ID: 15974133
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Investigations of a new field in gas chromatography: capillary columns with a super-thick layer of stationary liquid phase.
    Berezkin VG; Lapin AB; Lipsky JB
    J Chromatogr A; 2005 Aug; 1084(1-2):18-23. PubMed ID: 16114231
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preparation, characterization and application of polymethacrylate-based monolithic columns for fast and efficient separation of alkanes, alcohols, alkylbenzenes and isomeric mixtures by gas chromatography.
    Obbed MS; Aqel A; Al Othman ZA; Badjah-Hadj-Ahmed AY
    J Chromatogr A; 2018 Jun; 1555():89-99. PubMed ID: 29724647
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Single fiber-in-capillary annular column for gas chromatographic separation.
    Li P; Xu Z; Yang X; Bi W; Xiao D; Choi MM
    J Chromatogr A; 2009 Apr; 1216(15):3343-8. PubMed ID: 19268954
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Achieving high peak capacity production for gas chromatography and comprehensive two-dimensional gas chromatography by minimizing off-column peak broadening.
    Wilson RB; Siegler WC; Hoggard JC; Fitz BD; Nadeau JS; Synovec RE
    J Chromatogr A; 2011 May; 1218(21):3130-9. PubMed ID: 21255787
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A microchip gas chromatography column assembly with a 3D metal printing micro column oven and a flexible stainless-steel column.
    Meng H; Wei Y; Feng L
    J Chromatogr A; 2024 Aug; 1729():465036. PubMed ID: 38843573
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-speed gas chromatography: an overview of various concepts.
    Cramers CA; Janssen HG; van Deursen MM; Leclercq PA
    J Chromatogr A; 1999 Sep; 856(1-2):315-29. PubMed ID: 10526794
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of gas-liquid partition coefficients of several organic solutes in trihexyl(tetradecyl)phosphonium bromide using capillary gas chromatography columns.
    Ronco NR; Menestrina F; Romero LM; Castells CB
    J Chromatogr A; 2017 Jun; 1501():134-141. PubMed ID: 28457488
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Uncoated capillary column inlets (retention gaps) in gas chromatography.
    Grob K; Schilling B
    J Chromatogr; 1987 Mar; 391(1):3-18. PubMed ID: 3294873
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Potential of wide bore open tubular columns in gas chromatographic analysis of drugs.
    Mehta AC
    J Chromatogr; 1989 Sep; 494():1-11. PubMed ID: 2685001
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prediction of retention times in linear gradient temperature and pressure programmed analysis on capillary columns.
    Vezzani S; Moretti P; Mazzi M; Castello G
    J Chromatogr A; 2004 Nov; 1055(1-2):151-8. PubMed ID: 15560491
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prediction of the plate height of capillary columns operated at any inlet pressure of the carrier gas by using few retention data measured under isobaric conditions.
    Vezzani S; Moretti P; Castello G
    J Chromatogr A; 2003 Apr; 994(1-2):103-25. PubMed ID: 12779223
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prediction of theoretical plate number in isothermal gas chromatographic analysis on capillary columns.
    Moretti P; Vezzani S; Castello G
    J Chromatogr A; 2006 Nov; 1133(1-2):305-14. PubMed ID: 16959257
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The use of silica nanoparticles for gas chromatographic separation.
    Na N; Cui X; De Beer T; Liu T; Tang T; Sajid M; Ouyang J
    J Chromatogr A; 2011 Jul; 1218(28):4552-8. PubMed ID: 21652043
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gas chromatography: elution temperature, speed of analysis, and separation, efficiency as influenced by rate of temperature programming and carrier gas velocity in open tubular glass capillary columns.
    Jennings WG; Adam S
    Anal Biochem; 1975 Nov; 69(1):61-9. PubMed ID: 1211640
    [No Abstract]   [Full Text] [Related]  

  • 16. Comparing columns for gas chromatography with the two-parameter model for retention prediction.
    Thewalim Y; Sadiktsis I; Colmsjö A
    J Chromatogr A; 2011 Aug; 1218(31):5305-10. PubMed ID: 21722909
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polyimide polymer glass-free capillary columns for gas chromatography.
    Webster JG; Marine SS; Danielson ND
    J Chromatogr Sci; 2011; 49(6):447-56. PubMed ID: 21682994
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comprehensive two-dimensional gas chromatography with a multi-capillary second dimension: a new column-set format for simultaneous optimum linear velocity operation.
    Peroni D; Sampat AA; van Egmond W; de Koning S; Cochran J; Lautamo R; Janssen HG
    J Chromatogr A; 2013 Nov; 1317():3-11. PubMed ID: 23953614
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Preparation of capillary gas chromatographic columns for separation of polar organic compounds by sol-gel method].
    Wang DX; Malik A
    Se Pu; 2002 May; 20(3):279-82. PubMed ID: 12541958
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization by the solvation parameter model of the retention properties of commercial ionic liquid columns for gas chromatography.
    Rodríguez-Sánchez S; Galindo-Iranzo P; Soria AC; Sanz ML; Quintanilla-López JE; Lebrón-Aguilar R
    J Chromatogr A; 2014 Jan; 1326():96-102. PubMed ID: 24373774
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.