These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
114 related articles for article (PubMed ID: 15976964)
1. The Bad Oeynhausen concept of INR self-management. Koertke H; Zittermann A; Mommertz S; El-Arousy M; Litmathe J; Koerfer R J Thromb Thrombolysis; 2005 Feb; 19(1):25-31. PubMed ID: 15976964 [TBL] [Abstract][Full Text] [Related]
2. International normalized ratio patient self-management for mechanical valves: is it safe enough? Koerfer R; Reiss N; Koertke H Curr Opin Cardiol; 2009 Mar; 24(2):130-5. PubMed ID: 19532098 [TBL] [Abstract][Full Text] [Related]
3. Low-dose international normalized ratio self-management: a promising tool to achieve low complication rates after mechanical heart valve replacement. Koertke H; Zittermann A; Minami K; Tenderich G; Wagner O; El-Arousy M; Krian A; Ennker J; Taborski U; Klövekorn WP; Moosdorf R; Saggau W; Morshuis M; Koerfer J; Seifert D; Koerfer R Ann Thorac Surg; 2005 Jun; 79(6):1909-14; discussion 1914. PubMed ID: 15919283 [TBL] [Abstract][Full Text] [Related]
4. Self-management of oral anticoagulation therapy--methodological and clinical aspects. Christensen TD Dan Med Bull; 2011 May; 58(5):B4284. PubMed ID: 21535992 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of warfarin management with international normalized ratio self-testing and online remote monitoring and management plus low-dose vitamin k with genomic considerations: a pilot study. Bussey HI; Bussey M; Bussey-Smith KL; Frei CR Pharmacotherapy; 2013 Nov; 33(11):1136-46. PubMed ID: 24038412 [TBL] [Abstract][Full Text] [Related]
6. A prospective controlled trial comparing weekly self-testing and self-dosing with the standard management of patients on stable oral anticoagulation. Watzke HH; Forberg E; Svolba G; Jimenez-Boj E; Krinninger B Thromb Haemost; 2000 May; 83(5):661-5. PubMed ID: 10823258 [TBL] [Abstract][Full Text] [Related]
7. International normalized ratio self-management lowers the risk of thromboembolic events after prosthetic heart valve replacement. Eitz T; Schenk S; Fritzsche D; Bairaktaris A; Wagner O; Koertke H; Koerfer R Ann Thorac Surg; 2008 Mar; 85(3):949-54; discussion 955. PubMed ID: 18291177 [TBL] [Abstract][Full Text] [Related]
8. Oral anticoagulation self-management and management by a specialist anticoagulation clinic: a randomised cross-over comparison. Cromheecke ME; Levi M; Colly LP; de Mol BJ; Prins MH; Hutten BA; Mak R; Keyzers KC; Büller HR Lancet; 2000 Jul; 356(9224):97-102. PubMed ID: 10963245 [TBL] [Abstract][Full Text] [Related]
9. International normalized ratio self-testing and self-management: improving patient outcomes. Pozzi M; Mitchell J; Henaine AM; Hanna N; Safi O; Henaine R Vasc Health Risk Manag; 2016; 12():387-392. PubMed ID: 27785043 [TBL] [Abstract][Full Text] [Related]
10. A structured teaching and self-management program for patients receiving oral anticoagulation: a randomized controlled trial. Working Group for the Study of Patient Self-Management of Oral Anticoagulation. Sawicki PT JAMA; 1999 Jan; 281(2):145-50. PubMed ID: 9917117 [TBL] [Abstract][Full Text] [Related]
11. Self-management of oral anticoagulation in the elderly: rationale, design, baselines and oral anticoagulation control after one year of follow-up. A randomized controlled trial. Siebenhofer A; Rakovac I; Kleespies C; Piso B; Didjurgeit U Thromb Haemost; 2007 Mar; 97(3):408-16. PubMed ID: 17334508 [TBL] [Abstract][Full Text] [Related]
12. Improvement of oral anticoagulation therapy by INR self-management. Horstkotte D; Piper C J Heart Valve Dis; 2004 May; 13(3):335-8. PubMed ID: 15222277 [TBL] [Abstract][Full Text] [Related]
13. Low-dose oral anticoagulation in patients with mechanical heart valve prostheses: final report from the early self-management anticoagulation trial II. Koertke H; Zittermann A; Tenderich G; Wagner O; El-Arousy M; Krian A; Ennker J; Taborski U; Klövekorn WP; Moosdorf R; Saggau W; Koerfer R Eur Heart J; 2007 Oct; 28(20):2479-84. PubMed ID: 17890730 [TBL] [Abstract][Full Text] [Related]
14. Experience with INR self-management: patient selection and complication rates. Voeller H; Dovifat C; Wegscheider K Z Kardiol; 2005 Dec; 94(12):801-7. PubMed ID: 16382380 [TBL] [Abstract][Full Text] [Related]
16. [Update of INR-selfmonitoring]. Völler H; Braun S Hamostaseologie; 2008 Oct; 28(4):231-3. PubMed ID: 18836650 [TBL] [Abstract][Full Text] [Related]
17. Comparison of the international normalized ratio levels obtained by portable coagulometer and laboratory in a clinic specializing in oral anticoagulation. Meneghelo ZM; Barroso CM; Liporace IL; Cora AP Int J Lab Hematol; 2015 Aug; 37(4):536-43. PubMed ID: 25754527 [TBL] [Abstract][Full Text] [Related]
18. In-patient international normalized ratio self-testing instruction after mechanical heart valve implantation. Thompson JL; Sundt TM; Sarano ME; Santrach PJ; Schaff HV Ann Thorac Surg; 2008 Jun; 85(6):2046-50. PubMed ID: 18498817 [TBL] [Abstract][Full Text] [Related]
20. Real-World Impact of Setting a Narrow International Normalized Ratio Target Range in the Management of Older Adult Patients on Warfarin. Ong PY; Koomanan N; Cheen MH; Lai YF; Lim SH; Kong MC; Ng HJ Clin Appl Thromb Hemost; 2016 Sep; 22(6):528-34. PubMed ID: 26239317 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]