135 related articles for article (PubMed ID: 15987098)
1. Monolithic capillary-based ion-selective electrodes.
Vigassy T; Huber CG; Wintringer R; Pretsch E
Anal Chem; 2005 Jul; 77(13):3966-70. PubMed ID: 15987098
[TBL] [Abstract][Full Text] [Related]
2. Rotating disk potentiometry for inner solution optimization of low-detection-limit ion-selective electrodes.
Radu A; Telting-Diaz M; Bakker E
Anal Chem; 2003 Dec; 75(24):6922-31. PubMed ID: 14670054
[TBL] [Abstract][Full Text] [Related]
3. Cs+ -selective membrane electrodes based on ethylene glycol-functionalized polymeric microspheres.
Peper S; Gonczy C; Runde W
Talanta; 2005 Oct; 67(4):713-7. PubMed ID: 18970229
[TBL] [Abstract][Full Text] [Related]
4. Determination of the leaching of polymeric ion-selective membrane components by stripping voltammetry.
Paczosa-Bator B; Piech R; Lewenstam A
Talanta; 2010 May; 81(3):1003-9. PubMed ID: 20298885
[TBL] [Abstract][Full Text] [Related]
5. Fiber-optic microsensor array based on fluorescent bulk optode microspheres for the trace analysis of silver ions.
Wygladacz K; Radu A; Xu C; Qin Y; Bakker E
Anal Chem; 2005 Aug; 77(15):4706-12. PubMed ID: 16053279
[TBL] [Abstract][Full Text] [Related]
6. Electrochemical methods for the determination of the diffusion coefficient of ionophores and ionophore-ion complexes in plasticized PVC membranes.
Bodor S; Zook JM; Lindner E; Tóth K; Gyurcsányi RE
Analyst; 2008 May; 133(5):635-42. PubMed ID: 18427685
[TBL] [Abstract][Full Text] [Related]
7. Sulfonated poly(ether ether ketone) as an alternative charged material to poly(vinyl chloride) in the design of ion-selective electrodes.
González-Bellavista A; Macanás J; Muñoz M; Fabregas E
Anal Chim Acta; 2006 Sep; 577(1):85-90. PubMed ID: 17723657
[TBL] [Abstract][Full Text] [Related]
8. How to assess the limits of ion-selective electrodes: method for the determination of the ultimate span, response range, and selectivity coefficients of neutral carrier-based cation selective electrodes.
Bereczki R; Takács B; Langmaier J; Neely M; Gyurcsányi RE; Tóth K; Nagy G; Lindner E
Anal Chem; 2006 Feb; 78(3):942-50. PubMed ID: 16448072
[TBL] [Abstract][Full Text] [Related]
9. Plasticizer-level study of poly(vinyl chloride) ion-selective membranes.
Simon MA; Kusy RP
J Biomed Mater Res; 1996 Mar; 30(3):313-20. PubMed ID: 8698694
[TBL] [Abstract][Full Text] [Related]
10. Thin layer coulometry with ionophore based ion-selective membranes.
Grygolowicz-Pawlak E; Bakker E
Anal Chem; 2010 Jun; 82(11):4537-42. PubMed ID: 20429515
[TBL] [Abstract][Full Text] [Related]
11. An experimental study of membrane materials and inner contacting layers for ion-selective K+ electrodes with a stable response and good dynamic range.
Michalska AJ; Appaih-Kusi C; Heng LY; Walkiewicz S; Hall EA
Anal Chem; 2004 Apr; 76(7):2031-9. PubMed ID: 15053668
[TBL] [Abstract][Full Text] [Related]
12. Improving the detection limits of antispasmodic drugs electrodes by using modified membrane sensors with inner solid contact.
Ibrahim H; Issa YM; Abu-Shawish HM
J Pharm Biomed Anal; 2007 May; 44(1):8-15. PubMed ID: 17383844
[TBL] [Abstract][Full Text] [Related]
13. Polymeric plasticizer extends the lifetime of PVC-membrane ion-selective electrodes.
Zahran EM; New A; Gavalas V; Bachas LG
Analyst; 2014 Feb; 139(4):757-63. PubMed ID: 24352534
[TBL] [Abstract][Full Text] [Related]
14. Cefuroxime selective electrodes for batch and FIA determinations in pharmaceutical preparations.
Lima JL; Montenegro MC; Sales MG
J Pharm Biomed Anal; 1998 Oct; 18(1-2):93-103. PubMed ID: 9863947
[TBL] [Abstract][Full Text] [Related]
15. Determination of cobalt ions at nano-level based on newly synthesized pendant armed macrocycle by polymeric membrane and coated graphite electrode.
Singh AK; Singh P; Bhattacharjee G
Talanta; 2009 Dec; 80(2):685-93. PubMed ID: 19836538
[TBL] [Abstract][Full Text] [Related]
16. Ion-pairing ability, chemical stability, and selectivity behavior of halogenated dodecacarborane cation exchangers in neutral carrier-based ion-selective electrodes.
Peper S; Qin Y; Almond P; McKee M; Telting-Diaz M; Albrecht-Schmitt T; Bakker E
Anal Chem; 2003 May; 75(9):2131-9. PubMed ID: 12720352
[TBL] [Abstract][Full Text] [Related]
17. Potentiometric sensor for heparin polyion: transient behavior and response mechanism.
Langmaier J; Samcova E; Samec Z
Anal Chem; 2007 Apr; 79(7):2892-900. PubMed ID: 17315978
[TBL] [Abstract][Full Text] [Related]
18. Microspheres aided introduction of ionophore and ion-exchanger to the ion-selective membrane.
Wojciechowski M; Kisiel A; Bulska E; Michalska A
Talanta; 2012 Jan; 88():66-72. PubMed ID: 22265471
[TBL] [Abstract][Full Text] [Related]
19. Optimization of polymeric triiodide membrane electrode based on clozapine-triiodide ion-pair using experimental design.
Farhadi K; Bahram M; Shokatynia D; Salehiyan F
Talanta; 2008 Jul; 76(2):320-6. PubMed ID: 18585284
[TBL] [Abstract][Full Text] [Related]
20. Novel method to prepare polystyrene-based monolithic columns for chromatographic and electrophoretic separations by microwave irradiation.
Zhang YP; Ye XW; Tian MK; Qu LB; Choi SH; Gopalan AI; Lee KP
J Chromatogr A; 2008 Apr; 1188(1):43-9. PubMed ID: 18037422
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]