These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

391 related articles for article (PubMed ID: 15987969)

  • 1. Radiofrequency versus microwave ablation in a hepatic porcine model.
    Wright AS; Sampson LA; Warner TF; Mahvi DM; Lee FT
    Radiology; 2005 Jul; 236(1):132-9. PubMed ID: 15987969
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of microwave ablation and bipolar radiofrequency ablation both with an internally cooled probe: results in ex vivo and in vivo porcine livers.
    Yu J; Liang P; Yu X; Liu F; Chen L; Wang Y
    Eur J Radiol; 2011 Jul; 79(1):124-30. PubMed ID: 20047812
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-powered microwave ablation with a small-gauge, gas-cooled antenna: initial ex vivo and in vivo results.
    Lubner MG; Hinshaw JL; Andreano A; Sampson L; Lee FT; Brace CL
    J Vasc Interv Radiol; 2012 Mar; 23(3):405-11. PubMed ID: 22277272
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microwave ablation compared with radiofrequency ablation for breast tissue in an ex vivo bovine udder model.
    Tanaka T; Westphal S; Isfort P; Braunschweig T; Penzkofer T; Bruners P; Kichikawa K; Schmitz-Rode T; Mahnken AH
    Cardiovasc Intervent Radiol; 2012 Aug; 35(4):914-20. PubMed ID: 21833802
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thermal ablation of lung tissue: in vivo experimental comparison of microwave and radiofrequency.
    Crocetti L; Bozzi E; Faviana P; Cioni D; Della Pina C; Sbrana A; Fontanini G; Lencioni R
    Cardiovasc Intervent Radiol; 2010 Aug; 33(4):818-27. PubMed ID: 20442998
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of variation of portal venous blood flow on radiofrequency and microwave ablations in a blood-perfused bovine liver model.
    Dodd GD; Dodd NA; Lanctot AC; Glueck DA
    Radiology; 2013 Apr; 267(1):129-36. PubMed ID: 23297326
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Internally gas-cooled radiofrequency applicators as an alternative to conventional radiofrequency and microwave ablation devices: an in vivo comparison.
    Rempp H; Voigtländer M; Schenk M; Enderle MD; Scharpf M; Greiner TO; Neugebauer A; Hoffmann R; Claussen CD; Clasen S
    Eur J Radiol; 2013 Aug; 82(8):e350-5. PubMed ID: 23522746
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pulmonary thermal ablation: comparison of radiofrequency and microwave devices by using gross pathologic and CT findings in a swine model.
    Brace CL; Hinshaw JL; Laeseke PF; Sampson LA; Lee FT
    Radiology; 2009 Jun; 251(3):705-11. PubMed ID: 19336667
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Combination Therapies: Quantifying the Effects of Transarterial Embolization on Microwave Ablation Zones.
    Knavel EM; Green CM; Gendron-Fitzpatrick A; Brace CL; Laeseke PF
    J Vasc Interv Radiol; 2018 Jul; 29(7):1050-1056. PubMed ID: 29754849
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Radiofrequency and microwave ablation in a porcine liver model: non-contrast CT and ultrasound radiologic-pathologic correlation.
    Ziemlewicz TJ; Hinshaw JL; Lubner MG; Knott EA; Willey BJ; Lee FT; Brace CL
    Int J Hyperthermia; 2020; 37(1):799-807. PubMed ID: 32620055
    [No Abstract]   [Full Text] [Related]  

  • 11. Efficacy of microwave versus radiofrequency ablation for treatment of small hepatocellular carcinoma: experimental and clinical studies.
    Qian GJ; Wang N; Shen Q; Sheng YH; Zhao JQ; Kuang M; Liu GJ; Wu MC
    Eur Radiol; 2012 Sep; 22(9):1983-90. PubMed ID: 22544225
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 915MHz microwave ablation with high output power in in vivo porcine spleens.
    Gao Y; Wang Y; Duan Y; Li C; Sun Y; Zhang D; Lu T; Liang P
    Eur J Radiol; 2010 Jul; 75(1):87-90. PubMed ID: 19349134
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microwave ablation with a single small-gauge triaxial antenna: in vivo porcine liver model.
    Brace CL; Laeseke PF; Sampson LA; Frey TM; van der Weide DW; Lee FT
    Radiology; 2007 Feb; 242(2):435-40. PubMed ID: 17255414
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comparison study of microwave ablation vs. histotripsy for focal liver treatments in a swine model.
    Knott EA; Zlevor AM; Hinshaw JL; Laeseke PF; Longhurst C; Frank J; Bradley CW; Couillard AB; Rossebo AE; Xu Z; Lee FT; Ziemlewicz TJ
    Eur Radiol; 2023 Feb; 33(2):1050-1062. PubMed ID: 36048208
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury.
    Whayne JG; Nath S; Haines DE
    Circulation; 1994 May; 89(5):2390-5. PubMed ID: 8181165
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microwave ablation of liver tumors: degree of tissue contraction as compared to RF ablation.
    Lee JK; Siripongsakun S; Bahrami S; Raman SS; Sayre J; Lu DS
    Abdom Radiol (NY); 2016 Apr; 41(4):659-66. PubMed ID: 27039193
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of temperature curve and ablation zone between 915- and 2450-MHz cooled-shaft microwave antenna: results in ex vivo porcine livers.
    Sun Y; Cheng Z; Dong L; Zhang G; Wang Y; Liang P
    Eur J Radiol; 2012 Mar; 81(3):553-7. PubMed ID: 21354733
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microwave ablation versus radiofrequency ablation in the kidney: high-power triaxial antennas create larger ablation zones than similarly sized internally cooled electrodes.
    Laeseke PF; Lee FT; Sampson LA; van der Weide DW; Brace CL
    J Vasc Interv Radiol; 2009 Sep; 20(9):1224-9. PubMed ID: 19616970
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microwaves create larger ablations than radiofrequency when controlled for power in ex vivo tissue.
    Andreano A; Huang Y; Meloni MF; Lee FT; Brace C
    Med Phys; 2010 Jun; 37(6):2967-73. PubMed ID: 20632609
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of wet radiofrequency ablation with dry radiofrequency ablation and radiofrequency ablation using hypertonic saline preinjection: ex vivo bovine liver.
    Lee JM; Han JK; Kim SH; Shin KS; Lee JY; Park HS; Hur H; Choi BI
    Korean J Radiol; 2004; 5(4):258-65. PubMed ID: 15637476
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.