208 related articles for article (PubMed ID: 15996061)
1. Falsely elevated cardiac troponin-I in patients with seropositive rheumatoid arthritis.
Kenny PR; Finger DR
J Rheumatol; 2005 Jul; 32(7):1258-61. PubMed ID: 15996061
[TBL] [Abstract][Full Text] [Related]
2. Serum concentrations of cardiac troponin-I in patients with rheumatoid arthritis, systemic lupus erythematosus, primary Sjogren's syndrome and Graves' disease.
Al-Awadhi AM; Olusi S; Hasan EA; Abdullah A
Singapore Med J; 2007 Sep; 48(9):847-9. PubMed ID: 17728967
[TBL] [Abstract][Full Text] [Related]
3. False positive elevation of cardiac troponin I in seropositive rheumatoid arthritis.
Katwa G; Komatireddy G; Walker SE
J Rheumatol; 2001 Dec; 28(12):2750-1. PubMed ID: 11764229
[TBL] [Abstract][Full Text] [Related]
4. Detection of myocardial injury in patients with unstable angina using a novel nanoparticle cardiac troponin I assay: observations from the PROTECT-TIMI 30 Trial.
Wilson SR; Sabatine MS; Braunwald E; Sloan S; Murphy SA; Morrow DA
Am Heart J; 2009 Sep; 158(3):386-91. PubMed ID: 19699861
[TBL] [Abstract][Full Text] [Related]
5. Positive interference from contrast media in cardiac troponin I immunoassays.
Lin CT; Lee HC; Voon WC; Yen HW; Tang MH; Chin TT; Chen WR; Chien WT; Lai WT; Sheu SH
Kaohsiung J Med Sci; 2006 Mar; 22(3):107-13. PubMed ID: 16602274
[TBL] [Abstract][Full Text] [Related]
6. Interpretation of high sensitivity cardiac troponin I results: reference to biological variability in patients who present to the emergency room with chest pain: case report series.
Wu AH
Clin Chim Acta; 2009 Mar; 401(1-2):170-4. PubMed ID: 19135041
[TBL] [Abstract][Full Text] [Related]
7. Troponin I: an update on clinical utility and method standardization.
Laurino JP
Ann Clin Lab Sci; 2000 Oct; 30(4):412-21. PubMed ID: 11045766
[TBL] [Abstract][Full Text] [Related]
8. Elevated levels of IgM and IgA antibodies to Proteus mirabilis and IgM antibodies to Escherichia coli are associated with early rheumatoid factor (RF)-positive rheumatoid arthritis.
Newkirk MM; Goldbach-Mansky R; Senior BW; Klippel J; Schumacher HR; El-Gabalawy HS
Rheumatology (Oxford); 2005 Nov; 44(11):1433-41. PubMed ID: 16091399
[TBL] [Abstract][Full Text] [Related]
9. [Differences in cardiac troponin I and T levels measured in asymptomatic hemodialysis patients with last generation immunoassays].
Deléaval P; Descombes E; Magnin JL; Martin PY; Fellay G
Nephrol Ther; 2006 May; 2(2):75-81. PubMed ID: 16895718
[TBL] [Abstract][Full Text] [Related]
10. False-positive troponin I measured with the Abbott AxSYM attributed to fibrin interference.
Kazmierczak SC; Sekhon H; Richards C
Int J Cardiol; 2005 May; 101(1):27-31. PubMed ID: 15860379
[TBL] [Abstract][Full Text] [Related]
11. False positive elevation of cardiac troponin I in seropositive rheumatoid arthritis.
Bas S; Genevay S; Mensi N
J Rheumatol; 2002 Dec; 29(12):2665. PubMed ID: 12465175
[No Abstract] [Full Text] [Related]
12. Diagnostic impact of contemporary biomarker assays for rheumatoid arthritis.
Nikolaisen C; Rekvig OP; Nossent HC
Scand J Rheumatol; 2007; 36(2):97-100. PubMed ID: 17476614
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of the analytical performance of the advanced method for cardiac troponin I for the AxSYM platform: comparison with the old method and the Access system.
Storti S; Prontera C; Parri MS; Iervasi A; Vittorini S; Emdin M; Zucchelli GC; Longombardo G; Migliorini P; Clerico A
Clin Chem Lab Med; 2006; 44(8):1022-9. PubMed ID: 16879072
[TBL] [Abstract][Full Text] [Related]
14. Normal plasma levels of cardiac troponin I measured by the high-sensitivity cardiac troponin I access prototype assay and the impact on the diagnosis of myocardial ischemia.
Venge P; Johnston N; Lindahl B; James S
J Am Coll Cardiol; 2009 Sep; 54(13):1165-72. PubMed ID: 19761938
[TBL] [Abstract][Full Text] [Related]
15. New approach to standardisation of human cardiac troponin I (cTnI).
Katrukha A; Bereznikova A; Pettersson K
Scand J Clin Lab Invest Suppl; 1999; 230():124-7. PubMed ID: 10389210
[TBL] [Abstract][Full Text] [Related]
16. Anti-CCP2 is an adjunct to, not a surrogate for, rheumatoid factor in the diagnosis of rheumatoid arthritis: diagnostic utility of anti-CCP2 antibodies in Egyptian patients with rheumatoid arthritis.
Abdel-Nasser AM; Mahmoud MH; El Mansoury TM; Osman AM
Scand J Rheumatol; 2008; 37(5):329-36. PubMed ID: 18666028
[TBL] [Abstract][Full Text] [Related]
17. [High titers of rheumatoid factor: clinical significance].
Naranjo Hernández A; Rodríguez González T; Rodríguez-Lozano C; Ojeda Bruno S; Francisco Hernández F; Sánchez-García F; Bilbao Cantarero A
Rev Clin Esp; 1997 Apr; 197(4):232-6. PubMed ID: 9254397
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of 6 cardiac troponin assays in patients with acute coronary syndrome.
Saadeddin SM; Habbab MA; Siddieg HH; Al Seeni MN; Tahery AB; Dafterdar RM
Saudi Med J; 2003 Oct; 24(10):1092-7. PubMed ID: 14578975
[TBL] [Abstract][Full Text] [Related]
19. Prevalence of elevated troponin I in end-stage renal disease patients receiving hemodialysis.
Donnino MW; Karriem-Norwood V; Rivers EP; Gupta A; Nguyen HB; Jacobsen G; McCord J; Tomlanovich MC
Acad Emerg Med; 2004 Sep; 11(9):979-81. PubMed ID: 15347551
[TBL] [Abstract][Full Text] [Related]
20. Performance of the Advia Centaur second-generation troponin assay TnI-Ultra compared with the first-generation cTnI assay.
van de Kerkhof D; Peters B; Scharnhorst V
Ann Clin Biochem; 2008 May; 45(Pt 3):316-7. PubMed ID: 18482922
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]