89 related articles for article (PubMed ID: 1599980)
1. A collaborative trial for the evaluation of blood cholesterol measurement in clinical laboratories in Italy.
Malavasi B; Catapano A; Galli G; Franzini C
Eur J Clin Chem Clin Biochem; 1992 Mar; 30(3):157-61. PubMed ID: 1599980
[TBL] [Abstract][Full Text] [Related]
2. Matrix effects on proficiency testing materials. Impact on accuracy of cholesterol measurement in laboratories in the nation's largest hospital system.
Naito HK; Kwak YS; Hartfiel JL; Park JK; Travers EM; Myers GL; Ross JW; Eckfeldt JH; Hartmann AE
Arch Pathol Lab Med; 1993 Apr; 117(4):345-51. PubMed ID: 8466396
[TBL] [Abstract][Full Text] [Related]
3. Different effect of Intralipid and triacylglycerol rich lipoproteins on the Kodak Ektachem serum cholesterol determination.
Cobbaert C; Tricarico A
Eur J Clin Chem Clin Biochem; 1993 Feb; 31(2):107-9. PubMed ID: 8467010
[TBL] [Abstract][Full Text] [Related]
4. [Multicenter evaluation of four homogenous LDL-cholesterol assays].
Bayer P; Veinberg F; Couderc R; Cherfils C; Cambillau M; Cosson C; Fradin S; Gillery P; Steinmetz J; Legrand A; Egloff M; Beucler I
Ann Biol Clin (Paris); 2005; 63(1):27-41. PubMed ID: 15689310
[TBL] [Abstract][Full Text] [Related]
5. Analyses with the KODAK-Ektachem. Accuracy control using reference method values and the influence of protein concentration. Part I. Electrolytes.
Külpmann WR; Maibaum P; Sonntag O
J Clin Chem Clin Biochem; 1990 Nov; 28(11):825-33. PubMed ID: 2077095
[TBL] [Abstract][Full Text] [Related]
6. [Measurement of blood cholesterol, decentralized, using a Reflotron, or centralized in a laboratory. A comparison].
Christensen TE; Agner E; Jensen SE; Jacobsen K; Mahnfeldt MS; Baastrup A
Ugeskr Laeger; 1990 Nov; 152(45):3346-8. PubMed ID: 2238225
[TBL] [Abstract][Full Text] [Related]
7. An extraction/enzymatic procedure for serum cholesterol measurement: evaluation of performance characteristics.
Franzini C; Luraschi P
J Clin Chem Clin Biochem; 1990 Dec; 28(12):913-8. PubMed ID: 2081961
[TBL] [Abstract][Full Text] [Related]
8. Multicentric evaluation of the homogeneous LDL-cholesterol Plus assay: comparison with beta-quantification and Friedewald formula.
Esteban-Salan M; Aguilar-Doreste JA; Arranz-Pena ML; Juve-Cuxart S; Gich-Salarich I; Zapico-Muniz E; Ordonez-Llanos J
Clin Biochem; 2008 Nov; 41(16-17):1402-9. PubMed ID: 18722364
[TBL] [Abstract][Full Text] [Related]
9. Determination of reference method values by isotope dilution-gas chromatography/mass spectrometry: a five years' experience of two European Reference Laboratories.
Thienpont LM; Van Nieuwenhove B; Stöckl D; Reinauer H; De Leenheer AP
Eur J Clin Chem Clin Biochem; 1996 Oct; 34(10):853-60. PubMed ID: 8933112
[TBL] [Abstract][Full Text] [Related]
10. Matrix effects and the accuracy of cholesterol analysis.
Ross JW; Myers GL; Gilmore BF; Cooper GR; Naito HR; Eckfeldt J
Arch Pathol Lab Med; 1993 Apr; 117(4):393-400. PubMed ID: 8466403
[TBL] [Abstract][Full Text] [Related]
11. Multicentre evaluation of the Bayer DAX system.
Morosini L; Rossetti M; Berti P; Pallotti G; Fabbri V; Mambelli MC; Franceschin A; Dell'Anna L; Cappelletti P; Brocco G
Eur J Clin Chem Clin Biochem; 1993 Dec; 31(12):875-96. PubMed ID: 8136420
[TBL] [Abstract][Full Text] [Related]
12. Achieving accuracy for routine clinical chemistry methods by using patient specimen correlations to assign calibrator values. A means of managing matrix effects.
Lasky FD
Arch Pathol Lab Med; 1993 Apr; 117(4):412-9. PubMed ID: 8466405
[TBL] [Abstract][Full Text] [Related]
13. The how and why of an accuracy base for proficiency testing programs.
Welch MJ; Hertz HS
Arch Pathol Lab Med; 1988 Apr; 112(4):343-5. PubMed ID: 3355329
[TBL] [Abstract][Full Text] [Related]
14. Analyses with the KODAK-Ektachem. Accuracy control using reference method values and the influence of protein concentration. Part II. Substrates.
Külpmann WR; Maibaum P; Sonntag O; Schumann G; Siekmann L
J Clin Chem Clin Biochem; 1990 Nov; 28(11):835-43. PubMed ID: 2077096
[TBL] [Abstract][Full Text] [Related]
15. Results of a province-wide quality assurance program assessing the accuracy of cholesterol, triglycerides, and high-density lipoprotein cholesterol measurements and calculated low-density lipoprotein cholesterol in Ontario, using fresh human serum.
McQueen MJ; Henderson AR; Patten RL; Krishnan S; Wood DE; Webb S
Arch Pathol Lab Med; 1991 Dec; 115(12):1217-22. PubMed ID: 1768212
[TBL] [Abstract][Full Text] [Related]
16. An evaluation of two compact analyzers used for lipid analysis.
McKenney JM; Fary DF; Miller G; Proctor JD; Chinchili VM
J Fam Pract; 1993 May; 36(5):526-33. PubMed ID: 8482937
[TBL] [Abstract][Full Text] [Related]
17. The quality of analytical determinations of copper and zinc in serum. A collaborative study in a sample of Italian laboratories.
Patriarca M; Menditto A; Muran A; Morisi G
J Trace Elem Electrolytes Health Dis; 1993 Dec; 7(4):257-9. PubMed ID: 8019162
[TBL] [Abstract][Full Text] [Related]
18. [Standardization Committee for Haematology. External Quality Assurance Program for General Hematology. Evaluation of the 1994 results].
Gutiérrez G; Jou JM; Carlos Reverter J; Martínez-Brotons F; Domingo A; Antonio Iriarte J; Remacha A; Rey J; Vives Corrons JL
Sangre (Barc); 1996 Apr; 41(2):115-23. PubMed ID: 9045351
[TBL] [Abstract][Full Text] [Related]
19. Comparison of 2 homogeneous high-density lipoprotein cholesterol assays.
Hoang MP; Hirany SV; Parupia J; Devaraj S; Jialal I
Arch Pathol Lab Med; 1998 Nov; 122(11):1005-9. PubMed ID: 9822130
[TBL] [Abstract][Full Text] [Related]
20. The interlaboratorial quality assurance program for blood lead determination. An evaluation of methods and results.
Morisi G; Patriarca M; Taggi F
Ann Ist Super Sanita; 1989; 25(3):405-15. PubMed ID: 2624352
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]