These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 16001387)

  • 1. Spontaneous fracture of an implanted posterior chamber intraocular lens.
    Caça I; Unlü K; Ari S; Akşit I
    Eur J Ophthalmol; 2005; 15(4):507-9. PubMed ID: 16001387
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Spontaneous fracture of an implanted posterior chamber intraocular lens.
    Caca I; Unlu K; Ari S; Aksit I
    Eur J Ophthalmol; 2005; 15(4):507-509. PubMed ID: 28221415
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Traumatic fracture of posterior chamber intraocular lens.
    Das S; Patil MD; Garg P
    J Cataract Refract Surg; 2007 Dec; 33(12):2151-2. PubMed ID: 18053922
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Spontaneous fracture of an implanted posterior chamber polyimide intraocular lens haptic: a case report.
    Kang H; Han KE; Kim TI; Kim EK
    Indian J Ophthalmol; 2014 Mar; 62(3):348-50. PubMed ID: 23619497
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Late spontaneous haptic disinsertion from a three-piece intraocular lens.
    Solano JM; Baratz KH; Mahr MA; Erie JC
    Am J Ophthalmol; 2007 Mar; 143(3):521-2. PubMed ID: 17317403
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Traumatic fracture of flexible anterior chamber intraocular lenses.
    Capoferri C; Vacchi S; Tafi A; Voglini IM
    J Cataract Refract Surg; 1997 Nov; 23(9):1418-20. PubMed ID: 9423919
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Corneal decompensation and graft failure secondary to a broken posterior chamber poly(methyl methacrylate) intraocular lens haptic.
    Eleftheriadis H; Sahu DN; Willekens B; Vrensen GF; Liu CS
    J Cataract Refract Surg; 2001 Dec; 27(12):2047-50. PubMed ID: 11738925
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Surprising Cause for Corneal Edema after Cataract Surgery: A Missed Posterior Chamber Intraocular Lens Haptic Remnant.
    Elyashiv S; Barequet I
    Semin Ophthalmol; 2015; 30(5-6):450-3. PubMed ID: 24506516
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Silicone plate-haptic posterior chamber intraocular lens implanted in the anterior chamber: report of a bilateral case and potential complications.
    Izak AM; Werner L; Apple DJ; Pandey SK; Trivedi RH
    Ophthalmic Surg Lasers; 2002; 33(6):480-7. PubMed ID: 12449223
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Spontaneous disinsertion of a multipiece foldable acrylic intraocular lens haptic 3 and 12 months after implantation.
    Por YM; Chee SP
    J Cataract Refract Surg; 2004 May; 30(5):1139-42. PubMed ID: 15130659
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spontaneous posterior dislocation of an intraocular lens presenting as pupillary block glaucoma.
    Shankar J; Halliwell M
    J Cataract Refract Surg; 2003 Feb; 29(2):410-1. PubMed ID: 12648661
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Spontaneous fracture of an implanted anterior chamber lens].
    Weickert C; Fuhrmann G; Bleckmann H
    Ophthalmologe; 1992 Aug; 89(4):346-8. PubMed ID: 1304213
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A NOVEL TECHNIQUE FOR EXTRACTION OF DROPPED BROKEN HAPTICS OF HARD POSTERIOR CHAMBER INTRAOCULAR LENS.
    Elwan MM
    Retin Cases Brief Rep; 2021 Jan; 15(1):22-23. PubMed ID: 29557850
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Shape of lens epithelial cells after intraocular lens implantation.
    Majima K; Majima Y
    J Cataract Refract Surg; 2001 May; 27(5):745-52. PubMed ID: 11377907
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Update on fixation of rigid and foldable posterior chamber intraocular lenses. Part II: Choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacification.
    Ram J; Apple DJ; Peng Q; Visessook N; Auffarth GU; Schoderbek RJ; Ready EL
    Ophthalmology; 1999 May; 106(5):891-900. PubMed ID: 10328386
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Snowflake degeneration of polymethyl methacrylate posterior chamber intraocular lens optic material: a newly described clinical condition caused by unexpected late opacification of polymethyl methacrylate.
    Apple DJ; Peng Q; Arthur SN; Werner L; Merritt JH; Vargas LG; Hoddinott DS; Escobar-Gomez M; Schmidbauer JM
    Ophthalmology; 2002 Sep; 109(9):1666-75. PubMed ID: 12208715
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Broken part of IOL haptic as a cause of bullous keratopathy. Case report].
    Jurowski P
    Klin Oczna; 2005; 107(10-12):687-9. PubMed ID: 16619821
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bipseudophakia. Clinicopathological findings of a pseudophakic human globe obtained postmortem implanted with an anterior chamber and a posterior chamber intraocular lens.
    Izak AM; Pandey SK; Werner L; Apple DJ; Trivedi RH
    Indian J Ophthalmol; 2002 Mar; 50(1):49-51. PubMed ID: 12090087
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fracture of a polyimide-elastimide posterior chamber intraocular lens following blunt orbital trauma.
    Friehmann A; Sharon T; Ophir SS; Assia EI
    Eur J Ophthalmol; 2020 Sep; 30(5):NP79-NP81. PubMed ID: 30897947
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Late spontaneous prolapse of a posterior chamber intraocular lens.
    Sandhu R; Hunter P
    J Cataract Refract Surg; 2005 Dec; 31(12):2425-6. PubMed ID: 16473242
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.