These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 16003195)

  • 1. Interference Kirschner wires augment distal humeral fracture fixation in the elderly.
    Molloy S; Jasper LE; Burkhart BG; Brumback RJ; Belkoff SM
    J Orthop Trauma; 2005 Jul; 19(6):377-9. PubMed ID: 16003195
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Adjunct fixation with a Kirschner wire or a plate for lateral unicondylar humeral fracture stabilization.
    Coggeshall JD; Lewis DD; Iorgulescu A; Kim SE; Palm LS; Pozzi A
    Vet Surg; 2017 Oct; 46(7):933-941. PubMed ID: 28640455
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Schuhli augmentation of plate and screw fixation for humeral shaft fractures: a laboratory study.
    Simon JA; Dennis MG; Kummer FJ; Koval KJ
    J Orthop Trauma; 1999; 13(3):196-9. PubMed ID: 10206251
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Plate selection for fixation of extra-articular distal humerus fractures: a biomechanical comparison of three different implants.
    Scolaro JA; Hsu JE; Svach DJ; Mehta S
    Injury; 2014 Dec; 45(12):2040-4. PubMed ID: 25249244
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Locking plates in osteoporosis: a biomechanical cadaveric study of diaphyseal humerus fractures.
    Davis C; Stall A; Knutsen E; Whitney A; Becker E; Hsieh AH; OʼToole RV
    J Orthop Trauma; 2012 Apr; 26(4):216-21. PubMed ID: 22068207
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Double plate osteosynthesis provides better biomechanical stabilization than double tension band technique in distal humerus fractures.
    Doğramaci Y; Esen E; Kürklü M; Kirici Y; Atahan AO; Kömürcü M
    Eklem Hastalik Cerrahisi; 2010 Apr; 21(1):44-9. PubMed ID: 20302560
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of the angle between fracture line and Kirschner wires on stability in supracondylar humerus fractures treated with Kirschner wire fixation: A finite element analysis.
    Durusoy S; Öner K; Özer A; Sevinç HF
    Jt Dis Relat Surg; 2021; 32(1):75-84. PubMed ID: 33463421
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Adjunctive fixation of the humeral epicondyle in a lateral condylar fracture model: Ex vivo comparison of pins and plates with a novel composite (AdhFix).
    Quinn RJ; Höglund OV; Hutchinson DJ; Opande L; Lim E; Birgersson U; Granskog V; Malkoch M
    Vet Surg; 2024 Feb; 53(2):311-319. PubMed ID: 37932909
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.
    Korner J; Diederichs G; Arzdorf M; Lill H; Josten C; Schneider E; Linke B
    J Orthop Trauma; 2004; 18(5):286-93. PubMed ID: 15105750
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanical stability study of three techniques used in the fixation of transverse and oblique metaphyseal-diaphyseal junction fractures of the distal humerus in children: a finite element analysis.
    Liu C; Kamara A; Liu T; Yan Y; Wang E
    J Orthop Surg Res; 2020 Jan; 15(1):34. PubMed ID: 32020882
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical evaluation of proximal humeral fracture fixation supplemented with calcium phosphate cement.
    Kwon BK; Goertzen DJ; O'Brien PJ; Broekhuyse HM; Oxland TR
    J Bone Joint Surg Am; 2002 Jun; 84(6):951-61. PubMed ID: 12063329
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Are locking screws advantageous with plate fixation of humeral shaft fractures? A biomechanical analysis of synthetic and cadaveric bone.
    O'Toole RV; Andersen RC; Vesnovsky O; Alexander M; Topoleski LD; Nascone JW; Sciadini MF; Turen C; Eglseder WA
    J Orthop Trauma; 2008; 22(10):709-15. PubMed ID: 18978547
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A biomechanical comparison of Kirschner-wire fixation on fracture stability in Salter-Harris type I fractures of the proximal humeral physis in a porcine cadaveric model.
    Ma J; Wang T; Lovric V; Johnson KA; Walsh WR
    BMC Vet Res; 2017 Oct; 13(1):306. PubMed ID: 29070026
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures.
    Schliemann B; Seifert R; Rosslenbroich SB; Theisen C; Wähnert D; Raschke MJ; Weimann A
    J Shoulder Elbow Surg; 2015 Dec; 24(12):1968-73. PubMed ID: 26255200
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical Analysis of Screws Versus K-Wires for Lateral Humeral Condyle Fractures.
    Schlitz RS; Schwertz JM; Eberhardt AW; Gilbert SR
    J Pediatr Orthop; 2015 Dec; 35(8):e93-7. PubMed ID: 25985374
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical analysis between Orthofix® external fixator and different K-wire configurations for pediatric supracondylar humerus fractures.
    Li WC; Meng QX; Xu RJ; Cai G; Chen H; Li HJ
    J Orthop Surg Res; 2018 Jul; 13(1):188. PubMed ID: 30055630
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical comparison of fixation of two-part osteoporotic neck fracture of the proximal humerus using uni-planar and multi-planar Kirschner wire.
    Esen E; Doğramaci Y; Kömürcü M; Kanatli U; Bölükbaşi S; Atahan AO
    Eklem Hastalik Cerrahisi; 2009; 20(2):114-8. PubMed ID: 19619116
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Locked plate fixation of osteoporotic humeral shaft fractures: are two locking screws per segment enough?
    Hak DJ; Althausen P; Hazelwood SJ
    J Orthop Trauma; 2010 Apr; 24(4):207-11. PubMed ID: 20335752
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical comparison of different external fixator configurations for stabilization of supracondylar humerus fractures in children.
    Hohloch L; Konstantinidis L; Wagner FC; Strohm PC; Südkamp NP; Reising K
    Clin Biomech (Bristol, Avon); 2016 Feb; 32():118-23. PubMed ID: 26743869
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.
    Röderer G; Scola A; Schmölz W; Gebhard F; Windolf M; Hofmann-Fliri L
    Injury; 2013 Oct; 44(10):1327-32. PubMed ID: 23769470
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.